Aviosys IP POWER 9258T, IP POWER 9258S User Manual

IP POWER 9258 USER MANUAL
IP POWER 9258
USER MANUAL
IP POWER 9258 USER MANUAL
USER MANUAL
IP POWER 9258T / 9258S
Version: V1.38
2006.11
- 1 -
VER. X.X,
IP POWER 9258 USER MANUAL
Warning:
Any changes to this equipment without permission may cause damages to your equipment! This equipment has been proved by CE & FCC to can be prevented from the influence of harmful electronic jamming in normal business use condition.
IMPORTANT NOTICE
1. We have no responsibility for the possible damage caused by improper usage or abnormal working environment.
2. Do not use IP POWER in strong shaking condition.
3. Please contact the dealer If IP POWER works improperly.
Copyright © 2005 All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written consent of us
All other products mentioned in this document are trademarks of their respective
manufactures.
We are exempt from notify any change of our products.
- 2 -
IP POWER 9258 USER MANUAL
Table of Content
1. INTRODUCTION...........................................................................................................4
FEATURES..........................................................................................................................
9258
FUNCTION DESCRIBE.................................................................................................
2.SPECIFICATION............................................................................................................5
PACKAGE CONTENTS .........................................................................................................
MINIMUM SYSTEM REQUIREMENTS.....................................................................................
3.INTERFACE DESCRIPTION........................................................................................6
4.HARDWARE & SOFTWARE INSTALLATION...........................................................7
HARDWARE INSTALLATION ..................................................................................................
SOFTWARE INSTALLATION...................................................................................................
5. INITIAL SETTING.........................................................................................................8
INITIAL SETTING THROUGH ETHERNET.................................................................................
SETTING OF SOFTWARE SHUT DOWN CONTROLLED PC/ SERVER…………………….
6. HARDWARE CONTROL & SETTING……………………………………………….11.
7. CONTROL AND SETTING THROUTH THE INTERNET EXPLORE.................... 12
LOGIN.................................................................................................................................
CONTROL THE POWER SUPPLY OF OUTLETS……………………………………………….. POWER SUPPLY STATE QUERY……………………………………………………………...
SYSTEM SETTING............................................................................................................…
SETTING THE PASSWORD…………………………………………………………….…… SETTING THE IP ADDRESS.………………………………………………………………… EMAIL SETTINGS……………………………………………………………………….. … SETTING THE TIME SCHEDULE…………………………………………………………….. SETUP UP OWN OUTLET DEFAULT STATUS ………………….……………………………
. Internal Clock Settings & Network Time Protocol (NTP)………..……………………..
. WAKE ON LAN………………………………………………………………………………
. GPRS FOR CELL PHONE : SUPPORT WAP………………………………………………. . FIRMWARE UPDATE: …………………………………………………………………….
8. DDNS SETTING ……………………………………….………………….……………20
9. CHECK STATUS THROUGH SNMP ……………….………………….……………21
10. CONTROL AND SETTINGS THROUGH HTTP ORDER………………………….23
ORDER FORMAT……………………………………………………….…………………….
11. FAQ ……………………………………………………………….…………………….24
12. Webpage Customization ….………………………………….…………………….24
- 3 -
VER. X.X,
IP POWER 9258 USER MANUAL
1. Introduction
IP POWER 9258 is a web controller which can be easily used in the indust ry field. With the remote network control technology, user can control or query the power supply of equipment. User can do this in any computer connected to the internet or local area network, there is no special program needed, also there is no need to open the external case of the computer. Try to imagine that while traveling in a foreign country, you can control the power supply of your electric equipments, such as a computer, a server, a router, an entrance guard or security / surveillance system directly or use a time schedule comes with the IP POWER
9258. You can remotely control the power switch with any computer connected to the network, which is not only convenient, but it also big saving on the manpower and time.
Feature
1.
Built in web server, can be used through the Ethernet or Internet network .
kinds of real time state of 9258.
site ,
rnet
and hyperlinks to
6. Provide SDK (VB & VC) for own Software develop and application .
7. Safety shut down controlled PC/ Server ( WINDOWS OS )
are each outlet ON /OFF
2. Support multiple browser, such as Internet Explore, Netscape, you can operate the
switch and check the state without any special program .
3. Control 4set AC : outlet equipment at the same time.
* 9258T - Outlet NEMA5-15P / 9258S - Outlet IEC320-C13.
N - virtual IP 4. Supported HTTP, DDNS , SMTP, SNMP, INTERNET- fixed IP, DHCP, LA
5. Security passwords identify. Easily installed and can be updated online.
6. Supported RS232 port communication, indicate all
7. Separated LED indicates the state of each switch.
8. Develop tool (SNMP) is provided. It can be modified to meet the user’s special need.
9. Safely designed for high voltage resistance and protection for leakage of electrical
currency, using nonflammable material
10. Network Server reboot -- can remote control to reboot the power on for the PC or
Server at remote
11. Timer Schedule -- can pre-set the time schedule to turn power on / off thru Internet /
Ethernet.
12. Support NTP (Network Time Protocol ) - synchronize the time of 9258 to the Inte
web address time .
WAP Mo13. bile Phone Control - can use the GPRS cell phone via WAP to control
14. Setup up own outlet default : when regain power it store each outlet to those status
setting.
hics15. Arrange own webpage design : Change the user-defined grap
DK customize the web pages by webpage S
1 1
18. Local Hardw
Specification
* Maximum rated voltage for each 4 outlet : 250V AC, 24V DC
h 4 outlet : (Total) 15A AC/DC,
* Maximum rated currency: ( Individual outlet ) 6A AC/DC
* Maximum rated currency for eac
- 4 -
IP POWER 9258 USER MANUAL
- 5 -
* Ac * Working temperature: 0~ 70°C
tion delay: Max 10ms
2. Specification
Package contents
* 9258S - For EU / AU / UK
* 9258T – For USA / TW / JP
Option; RJ45 (Cat5) net wire Option : Power Cable ( Choose one)
Minimum System Requirements
Intel Pentium III 300MHz or above/compatible AMD CPU
0+SPI) & LINUX
t, ADSL or other ways, depends on whether you need far
ol ability or not)
NO
. IP Power 9258S : for 220-250V, please use power (IN) wire at 10A current..
2. IP Power 9258T : for 100-120V, please use power (IN) wire at 15A current.. Max output current: (total) 15A. Max (individual) 6A .
WINDOWS operating system (IE5.
Minimum 64MB RAM VGA Card: supported direct draw
Network card with RJ45 port & Ethernet HUB or Switcher
Internet network (Etherne end contr
TICES:
1
Max output current: (total) 10A. Max ( individual) 6A.
VER. X.X,
IP POWER 9258 USER MANUAL
3. Interface Description
IFP Power 9258
ront interface shown below:
ing solved the
update if update fail
. Output : T with daughter device - IP Power 9258 Outlet
Circle sign
From left to the right
1. RESET: self-protect AC reset button. IP Power 9258 can cut off the power supply of
utlets automatically if there is a shortcut or current overload. After user havo
problem, push the reset button, the AC power supply will become normal.
g outlet is power on. 2. LED: 4 LED indicator lights. If the LE D is on, means the correspon din
. RS232 port: provide the power output state a nd get IP address t o re-3
4 o connect
5.
and On & Off : H . Please do o refer
. RJ45 Ethernet port: link to the net wire.
ce shown below:
ardware power ON /OFF setup
page 11 for proper operation.
6
Rear interfa 9258S: :
9258T:
IP Power 9258.
3. OUT 1- 4 : 4 individually switched AC outlets
Port description (from left to the right)
1. 90-240VAC power input port
2. Power swi ch : the power switch ON /OFF of t
- 6 -
IP POWER 9258 USER MANUAL
X.X,
- 7 -
4. Hardware & Software installation
Before you star to use IP Power 9258, please follow the steps below
Check the package to make sure the contents is complete. Prepare one Ethernet HUB or Router Check the voltage of the power supply to make sure it is AC 110-240 volt Please confirm the specification of your power cable.
IP Power 9258S : for 220-250V, please use the 10A power cable. IP Power 9258T : for 100-120V, please use the 15A power cable.
Hardware installation
1 Connect the 9258 to HUB through network wire. 2 Connect the HUB or Router to the internet (may through ADSL/XDSL modem). 3 Connect the power adapter to the 9258. 4 Connect the power adapters of under control electric equipment to corresponding
out port of 9258.
Turn on your computer and the power adapter of IP Power 9258 for 220-250V, please use power wire can support 10A current..
Max. output current: (total) 10A , (individual) 6A.
• for 100-120V, please use power wire can support 15A current..
Max. output current: (total) 15A , (individual) 6A
Software installation
Having connected the power supply and network wire with RJ45 port to the 9258, please install the software by following the steps below:
1. Start your computer, put the installation disc in the CDROM, then find the file named ipeditv3.exe in the installation disc.
2. Copy the file to your desktop or any directory you want it saved to.
3. Start the initial setting process following the construction in next section.
VER.
IP POWER 9258 USER MANUAL
5. Initial Settings
Initial setting through the Ethernet
1. Open attached CD and save IPEDIT.exe in to your Hardisk , execute IPEdit.exe
2. All the IP 92XX series, like IP Power 9258 IP Kamera 9000 series/IP Video 9100 series
in the same subnet of the Ethernet will be found and be display in the window by the software. The default name of IP Power 9258 is IP 9258
.
3. Click the equipment‘s name that you want to edit in the left of the window; it will turn fuscous, the equipment’s name and IP address will display in the win dows, you can rename (use numbers and letters). After that, click the update button and the new setting will be work in 20 seconds.
4. Double click the name of the equipment you want to control, the IE browser window will open and connected to this equipment in that Ethernet a utomatically. You also can ty pe the IP address of the 9258 in the IE browser to open the web page of 9000. We suggest you to update the IE to version 6.0 with SP1 or higher if your IE notices you the security level is too low to open that web page.
NOTICE:
1. Make sure RJ45 network cable have been connected and the 9258 are power on.
- 8 -
Loading...
+ 20 hidden pages