1. IP POWER 9212 Delux was designed for indoor use, we carry no responsibility for possible damages caused by outdoor use, especially in the rain.。.
2. Please use the power adapter provided by the dealer, we carry no responsibility for the possible damage from using power adapters not .
4. Do not shake the IP POWER 9212 Delux in any fashion
5. Please contact the dealer If IP POWER 9212 Delux is not working properly.
Copyright © 2006 All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, re cording o r othe rwise, wit hout the prior written consent of us

All trademarks and products mentioned in this document are the properties of us.

IP POWER 9212 USER MANUAL
- 3 -
Table of Content
1. INTRODUCTION .......................................................................................................... 4
F
EATURES .........................................................................................................................
2.BEFORE YOU START ................................................................................................. 5
P
ACKAGE CONTENTS ........................................................................................................
INIMUM SYSTEM REQUIREMENTS ....................................................................................
M
3.INTERFACE DESCRIPTION ....................................................................................... 6
4.HARDWARE & SOFTWARE INSTALLATION .......................................................... 6
H
DWARE INSTALLATION .....................................................................................................
INPUT PRO HARDWARE CONNECT(RECOMMEND) ………………………………………
9201
OUTPUT OUTPUT PROHARDWARE
9202
CONNECT
5. INITIALIZATION ......................................................................................................... 14
(RECOMMEND) ………………………………………
OFTWARE INSTALLATION .................................................................................................
S
BASIC SETTIN G THRO UGH ETHERNET ................................................................................ .
ETTING OF SOFTWARE SHUT DOWN CONTROLLED PC/ SERVER……………..……….
S
6. SETTING AND CONTROL THROUGH THE INTERNET ...................................... 17
SYSTEM ADVANCE
PECIAL INTER-CONTROL ………………………………………………………… …….
S
CONFIGURATION .........................................................................................
SETING .......................................................................................................
DDNS SETTING ……………………………………………………………………….… SMTP FOR E-MAIL: INFORM IP ADDRESS & SENSOR TRIGGER. ………….………. CONTROL DI THROUGH TIME SCHEDUEL ………………………………………...
LOCK AND NTP SETTING………………………………………………………………….
C
ETWORK WAKE UP ……………………………………………………………………….
N
IRMWARE UPDATE…………………………………………………………………………
F
7. SETTING 9212 THROUGH THE INTERNET .......................................................... 31
8. APPLICATION ASSOCIATED TO OTHER IP PRODUCTS .................................. 32
9. FAQ ............................................................................................................................. 33
10. CONTROL AND SETUP BY HTTP COMMAND .................................................. 34
11. WEBPAGE CUSTOMIZATION .............................................................................. 37
VER. 1.10
- 4 -

1. Introduction

The IP Power 9212SDelux is a Network Controller & Sensor with 8 DI & 8 DO. No specific PC or software is needed to use the device. You can easily control devices remotely and check their status via the Internet from anywhere in the world.
Using a Browser such as Internet Explore or Netscape, you can securely access the unit. It includes 8 Digital Inputs (Dry / Wet contact which can be switched) , 8 Digital Relay Outputs that works like an IO Server. You can integrate it for Home, Office security, Personal entertainment, and Industrial field applications.
The API program is supported to help the integrator to easily program any software to integrate it with existing application systems in local computers. The IP POWER 9212 can be flexibly applied to Home entertainment & industry security & systems with integrated management.

Feature

1. Embedded web server – So the device does not need to be connected to a PC – Uses Ethernet or Internet (LAN / WAN)
2. Accessible with popular web browsers- IE (Internet Explore) or Netscape – DO NOT need specific Software.
3. Comes with 8DI & 8DO: Directly control relay output (DO) and detects digital input (DI)
* 8 Set Sensor – Default 4 Set Source mode (Dry - Voltage Input) and
& 4 Set Sink mode (Wet- Resistance Input).
Source & Sink mode can be switched.
* 8 Set Controllers – Default 4 Set NO - Normal Open & 4 Sets NC - Normal Close
4. Network protocols supported: HTTP,
5. Supports RS232 to control.
6. Security code identification and Hardware reset functions.
7. Individual LED indicates switch-working status.
8. Safe, durable, non-electric leakage and anti flammable design.
9. Polar protection – will even connect contrary port.
10. Digital inputs provide de-bouncing function.
11. Update firmware by the TCP/IP network.
12. Embedded “ WATCH DOG “,
15. Support SMTP: Send IP address as log in and send e-mail as detecting sensor trigger.
16. Auto Internal Control: DI Control DO (Own or other 9212Delux).
17 Time Scheduler -- pre-set the time schedule to turn power on / off thru Internet / Ethernet 18 Support NTP (Network Time Protocol) - synchronize the time of 9258 to the Internet web
19 WAP Mobile Phone Control - can use the GPRS cell phone via WAP to control 20 Setup up own outlet default: set DO status as regain power.
21 Provide SDK (VB & VC) for own Software develop and application. 22 Supply Exclu si ve IP Service for easily location of device on Internet by name.
Specification: 1. DC 5V (AC90-240 input) 2. D-SUB In & out port. 3. RJ45
DDNS, DHCP, Virtual and Dynamic IP.
IP POWER 9212 USER MANUAL
- 5 -
One network wire with RJ45 port
One 1A, 110~220V adaptor
TWO D-Sub 15 Pin cable
One install CD
One rapid install manual
Application field: can be used with any kind of electrical equipments, no matter household appliances or security equipments. It can manage the power supply through the web page; make it safer for the security equipment and more convenient for digital control at the far end.
Industrial applica tion field: Bank, financial security system, jewels, casino, cash register in supermarket, park, traffic control, military equipment and airport.

2. Before you start

9212 package contents

One set of IP POWER 9212 One set includes 3 separate units: 9200: Network Module (Base) 9201 Input: Input/Sensor Module 9202 Output: Control Module
   

Minimum Sy stem Requiremen ts

* Minimum Intel Pentium II 300MHz/compatible AMD processor * WINDOWS operating system (IE5.0+SP1) * Minimum 64MB RAM * VGA Card: with capability of displaying full-Colors and DirectDraw support * Network card with RJ45 port * Ethernet Hub / Router * Internet network (Ethernet, xDSL or other ways, depends on whether you need far end control ability or not)
VER. 1.10
- 6 -

3. Interface Description

IP Power 9212 has three units, 9200 is the network module (base), the picture below shows
the three units of the IP Power 921 2
9201 Input is the input /sensor mo dule and 9 202 Outp ut is the output / control module
:

4. Hardware & Software installation

Before you star using the IP Power 9212, please follow the steps below:
Check the package to make sure the contents are complete.  Prepare one Ethernet HUB, or Router  Check the voltage of the power supply to make sure it is AC 110-240 volt

Hardware In stallat ion: Connect RJ45 first (before connect P OWER jac k)

1 Connect the 9200 to HUB through RJ 45 netting cable.
2 Connect the 9200 ( IN-BLACK ) to 9201( BLACK port) &
9200 ( OUT- BLUE ) to 9202 Output ( BLUE) throug h D-S UB
cable.
3 Connect the HUB to the Internet (May through ADSL/XDSL modem). 4 Connect the power adapter to the 9200. Power on your computer and power adapter of IP POWER 9212.
IP POWER 9212 USER MANUAL
- 7 -

9201Pro Hardware connection (recommend):

4-1. Dry & Wet Setting
In the 9212Delux, the DRY or WET contact of each input (in 9201) can be selected. To setup t he Dr y or Wet contact of each input signal , please open 9201 Input case
and adjust the right blue switch only (The left switch was developed for further device enhancement and all signals must be kept on ON).
There is two blue switches in the 9201. Please arrange or leave all the setups in the Left
Switch to ON.
VER. 1.10
- 8 -
You can setup the Dry/Wet contact in the left blue switch:
Switch Set on Off = Wet
Switch Set on On = Dry
Default Settings (when no device a ttached):
Wet Contact: 1-4 = LED Off
Dry Contact: 5-8 = LED on
Note:
* When a wet contact device is attache d to output set t o wet the LED will turn o ff.
* When a dry contact device is atta ched to output s et to dr y the LED will turn on.
4-2 . Conne ction Il lustra tion:
For different request of normal state of electric equipment, 9201 Input offers four sets of voltage
signal IN1-IN4 and four sets of shortcut circuit signals IN5-IN8.
9201 Input Pro provide 4 set Source mode - Voltage Input – Out 1 ~ Out 4 ON : 4V~24V OFF : 0V ~ 3V
4 set Sink mode - Resistance input – Out 5 ~ Out 8. OFF: 200 ohm~ 0 ohm ON: 500 ohm ~
∞→LED(ON)→IE(ON) 0Ω→LED(OFF)→IE(OFF)
IP POWER 9212 USER MANUAL
- 9 -
1. The polari ty: R ight - Positive & Left – Negative .
NOTE: The polarity protective function, will protect your device if you reverse the polarity during
installation. But your device will not work correctly if the polarity is incorrect.
2. Source mode (Voltage signal) -- IN1 & IN4: can be connected to voltage signal detectors such as smoke detector, light detector and gas detector.
3. Sink mode (Resistance signal) —IN5 & IN8: can be connected to magnetic reed switch as the follow figures
VER. 1.10
- 10 -
It can be installed in the entrance guard or security equipment such as doors, windows, drawers and safe case..
Source mode (Voltage input) : IN1-IN4 contacts are active signal sensor. If the voltage difference between the two contacts in one set within 0V~3V, 9212 shows ON. It the voltage difference within 4V~24V, 9212 shows OFF. So user can detect the change of equipment. Such as smoke detector, light detector and gas detector.
NOTE:
1. The data in this figure is the average measure value. To ensure the correct detection, we suggest user set the voltage lower than 3V when it shows OFF and higher than 4V when it shows ON
2. The maximum measure voltage is 24V. .
Slink mode (Resistan ce Inp ut ) :
IN5-IN8 contacts are short circuit sensors. If the resistance between the two contacts in one set within 0Ω~200Ω, 9212 shows ON. If the resistance within 500Ω~ users can detect the movement of equipment through the magnetic reed switch or other kind of
reactive sensors.
NOTE:
1. The data in this figure is the average measure value. To ensure the correct detection, we suggest the user set the voltage
, 9212 shows OFF. So the
IP POWER 9212 USER MANUAL
- 11 -
lower than 200Ω when it shows ON and higher than 500Ω when it shows OFF.
2. When measuring the resistance of web contacts, the maximum voltage is 5V and the maximum currency is no more than 10mA
PS: magnetic reed switch: using the magnetic field of the magnet to produce a signal when there is a movement happened in switch. Low cost and easy to use is the chief characteristic of magnetic reed switch. Most of them are used in security equipment, living product and automatic mechanism.

9202 Output Pro Hard ware conn ection (r ecommend)

IP Power 9202 Output Pro has predefined Relay Statuses. Outputs 1 - 4: Normal Closed Relay (NC) Outputs 5 - 8: Normal Ope n Relay (NO)
(The relay status of the o utputs cannot b e change d: Meanin g that Outpu t 1-4 will always be Normally closed and Outputs 5-8 will always be Normally Open)
Maximum Rated Voltage: 240V/AC, 60V/DC Maximum Rated Currency: 12A AC/DC Maximum rated voltage for Single relay : 24V/ 10A , 120V/ 10A , 250/ 7A Maximum Switch time: Max 10ms Environment Temperature: -30°C~ + 55°C
NOTICE: Only the professionals should operate the following operations in this section
and the common user DO NOT try it!
For an example using a Light bulb
1.) Use the electrical wire of the equipment Step 1 : Cut off the live wire.Use a test pencil or screwdriver with voltage tester to identify the
live wire between the two wires of electrical wire.
NOTE: For this method you must cut off the electrical wire of the household appliance. Please
make the decision after reading method 5-2 and 5-3.
VER. 1.10
- 12 -
Step 2: Use a test pencil or screwdriver with voltage tester to identify the live wire between the two wires of electrical wire. Cut off the live wire and connect to the port of IP Power 9212. Use the
test pencil or screwdriver with voltage tester again to make sure the connection is correct. NOTICE: BE CAREFUL IN THIS OPERATION AND DO NOT TOUCH THE WIRE UNDER VOLTAGE WITH ANY PART OF YOUR BODY, ESPECIALLY WITH YOUR HANDS
2. Use additional electrical wire: you can buy some electrical wire and outlet in the electrical shop to cooperate with IP Power 9212, avoid cutting off the electrical wire of the equipment and can be used flexible in all kind of electrical equipment.
NOTICE: Use a test pencil or scr ewdriver with volta ge te ster to i dentify the li ve wire between the two wires of ele ctric al wire an d make sure of c onnecting the live wire to the port of IP Power 9212.
3. You an control multi power by use the power extension cord
IP POWER 9212 USER MANUAL
- 13 -
NOTICE: Do not connect too much e nergy inte nsive electr ical equi pment suc h as air
conditioner, electrical heater, microwave over or over in the same electrical outlet. Too much electri cal curr ency may cau se fir e. This produc t not guaranty the possible damage caused from too much electrical currency.

Software inst allation

Please follow the steps below to install the software.
1. Insert the RED CD in the package and windows will auto-run. If not please browse for the
Autorun.html file in CD.
.
2. Click IP KamVid 1070 in driver of CD and click OPEN top install the driver procedure.
3. Please follow the installation wizard and install all the recommended programs.
4. After installation is complete, a shortcut of “IPEDIT” & “INFINITY Cam” wi ll be created on the
Desktop and in program list of start of your computer
NOTE: * For NEW function – TO Record in “WMV” format, install IP KamVid 1070 .
VER. 1.10
- 14 -
5. Initialization

1. Initia l Ethern et setu p IPEDIT

1.) Click “ipEdit.exe”. (Please check the 9212A-SL for power and Ethernet connection.)
A. LOCAL Devices area:
IPEDIT will search for all IP Products 9XXX series in the same local Ethernet. The default name of the 9212Delux is “IP Power
1. Double click the IP address, it will highlight the device name, and IP information will be displayed to the right of the screen.
The IP address of 9212Delux should be in the same subnet with your PC, subnet mask, and default gateway must be the same as 9212Delux also.
For example, the IP address of 9212Delux is 192.168.10.9, so your computer needs to add an IP address looks like 192.168.10.XXX to get connection to 9212Delux.
2. User can change the device name (please use numbers or letter) or IP (please set in the same subnet as your PC) in the text window to the right. Then click Submit after setting finish. After about 20 seconds, the new setting will work. Click Update, the new setting of equipment will display in text window.
3. You can also cli ck “REF” in IPEDIT to check your PC to get the subnet information. And directly press “APPLY to“ update the new IP settings of selected 9212A-SL
IP POWER 9212 USER MANUAL
- 15 -
NOTICE:
1. Make sure the power and Ethernet connection of the 9212 are connect properly.
2. It can automatically obtain the virtual IP address after you run the ipeditv3.exe but only if your Ethernet supports DHCP. Click the IP address to enter the web page.
If your Ethernet does not support DHCP, IP92XX you will change its IP address to fixed IP address. Please follow the steps below to change the subnet of your PC:
3. If can not get in the 92XX web page, please set the segment of IP 9212Delux to be same as your PC.
* You can get your PC network information – IP Addres, Subnet Mask and Default Gateway by step: start  execute  key “cmd” in dialog key “ipconfig” in MS-DOS mode
The last digit of IP address can be any number between 1~254, but can not be same as your PC. If using in any PC, just use HUB and type the 192.168.0.100 in Browser or use
“ipedit.exe “ then you can get in the webpage. * Note: The first 3 segments of IP address of your device needs to be the same as your default
gateway. For Example: The IP address of the Gateway is 192.168.1.100, then the first 3 segments of the
IP address of your device will be 192.168.1.123.
4. The default username and password of IP Power 9212 are:
Username: admin Password: 12345678
If forget the new password:
Login: super user (There is a space between super and user Password: 1234568
VER. 1.10
- 16 -
Note : If the webpage does not load properly, and you see a error message which states“ Cookie time out “ Please delete your temporary internet files and cookies.
To do this go to IE: “ Tools “ “Internet Options”, please click “Delete Cookies“ and “Delete
files“ in “Temporary Internet file“.
B. Internet online devices:
By setting the server address in IP server of advanced setup page, the user can easily search for his/her IP Power 9212Delux on internet just by searching for the name of the device. The default
IP address of IP server is 220.135.169.136.
Step1: Click the green “connect” button Step2: In the device name section: Type in the name of your device (Min of 3 letters)
IP Server
IP Server gives the user the ability to easily search for the name of the device other than searching for a long IP number. This flexibility allows the user to easily just remember the name of their device so they can access it with ease.
To Enable IP Server: Go to Setup on the Left hand side of the Webpage and then make sure you have enabled Transmit IP Address to IP Server. The default IP server IP Address is provided but the user can also setup his/her own IPServer system and use that address as well.
IP POWER 9212 USER MANUAL
- 17 -

6. Control and settings through the Internet

Double click the IP address in IPEDIT and you can enter the login web page. Input the default password 12345678 (you can change the password after log in), click the OK and then you can enter the Web Control page.
Username: admin / Password: 12345678

Sensor of IP Power 9212: Read IO

Source mode (Voltage input):
IN1-IN4 contacts are active signal sensors. If the voltage difference between the two contacts in one set within 0V~3V, 9212 shows ON. It the voltage difference within 4V~24V, 9212 shows OFF. So user can detect the change of equipment. Such as smoke detector, light detector and gas detector.
Sink mode (Resista nce Input) :
IN5-IN8 contacts are short circuit sensors. If the resistance between the two contacts in one set within 0Ω~200Ω, 9212 shows ON. If the resistance within 500Ω~ can detect the movement of equipment through the magnetic reed switch or other kind of reactive sensors.
NOTE:
1. The data in this figure is the average measure value. To ensure the correct detection, we suggest user set the voltage lower than 200Ω when it shows ON and higher than 500Ω when it shows OFF.
, 9212 shows OFF. So user
VER. 1.10
- 18 -
2. When measuring the resistance of wet contacts, the maximum voltage is 5V and the maximum currency is no more than 10mA
Click the refresh button and you will see the similar figure like this. It represents the state of the four sets of input signals (there may be some delay, it up to your network).

Control of IP Power 9212: SET IO

IP Power 9212 now can control 8 outputs at the same time. * Out1 - Out4 are normally closed switches. When it is on, the corresponding LED lights up, the
circuit between the two connects is turn off. When it is off, the corresponding LED light off, the circuit between the two connects is turn on. * Out5 - Out8 are normally open switches. When it is on, the corresponding LED lights up, the
circuit between the two connects is turn on. When it is off, the corresponding LED light off, the circuit between the two connects is turn off.
IP POWER 9212 USER MANUAL
- 19 -
1. Control
Set the output’s state to ON/OFF Select the output you want to change and set it to ON or OFF state then click the apply
button.
2. Timer
Use the timer to set of f or on the out put after a s peci fic amou nt of ti me. Once y ou hit the apply button the timer st arts countin g down.
Example shows in the fig ure above means the OUT 3 will be in ON state when it starts and will c hanges t he state t o OFF a fter 30 sec onds.
3. Reset the ON/OFF setti ngs
Click the reset button you can cancel the previously output settings.

System configuration:

* Se tting the IP address for IP Power 9212Delux: Click the “Setup“ button on the left side under system.
Fill in the proper IP address, Subnet Mask, Default Gateway, and DNS. If you choose to use DHCP, please make sure that your network supports DHCP service so the IP Power 9212 will automatically find an IP address when it starts. You can also control the Beeper sound in system configuration..
IP Server: Register 9212Delux in our IP Server then user can easily get onl ine IP addre ss by “Name “search. Please refer page16 for this function.
VER. 1.10
- 20 -
* Http Command Verification: setup the control possibility from HTTP command or
SDK (VB & VC)
1. Select “ Cookie +Base64 “: enable Http command & SDK control
2. Select “ Cookie “: disable Http command & SDK control
2-1 IP address Settings: Ethernet (LAN) and Internet (WAN) 2-1-1 Local Area Network (LAN):
In LAN, you can set a fixed IP address or gain it from a DHCP server automatically. We suggest to use a fixed IP address in order to let the other computers can visit the 9212 Delux.
Now type the new IP address in the address field of IE, you can visit the 9212 Delux. You also can use the ipedit.exe to find the IP Power 9212 and modify its IP address.
2-1-2 Works on Internet (WAN): User can set the IP provided by your ISP. If the 9212 Delux has a public IP address, you can control it through the Internet. 9212 Delux supports fixed IP, DHCP.
* IP Address: please type in the IP address provided by your ISP. If IP Power 9212 Deluxe is
working with a Router, please refer to the network settings of the Router. * Subnet Mask: please type in the Subnet Mask provided by your ISP. If IP Power 9212 Delux is
working with a Router, please refer to the network settings of the Router. * Default gateway: please type in the Default Gateway provided by your ISP. If IP Power 9212
Delux is working with a Router, please refer to the network settings of the Router. * DNS Server: please fill in the IP address of DNS server. If you are in Taiwan, you can set it to
168.95.1.1.
* DHCP Clients: Enable– activate DHCP service. DHCP will assign IP address for each PC. Disable – shut down the DHCP service. You can set the IP address by yourself. * Beeper: Enable – activate the beeper. Disable – turn off the beeper. If you control the IP Power 9212 Delux through the web page, the beeper will
beep once when the operation work.
Note:
1) IP address format is: xxx.xxx.xxx.xxx: yyyyy. yyyyy represents the port number which ranges from 1 to 32767.
2) Subnet Mask: from 0 to 254 (xxx.xxx.xxx.0 ~ xxx.xxx.xxx.254)
3) If DHCP is disabled, user must set the TCP Port and default Gateway .If DHCP is
enabled, then the TCP port will be preset to 80( xxx.xxx.xxx.xxx: 80) and the The DHCP server will set default gateway, too.
4) If the TCP port you set is not 80, your should type in the whole IP address and port in IE or Netscape, such as to login into the virtual IP of IP Power 9212 Delux.
http://xxx.xxx.xxx.xxx:yyyyy, or you can use the ipedit.exe
Loading...