Datasheet E1205 Datasheet (Avery Weigh-Tronix)

Avery
Weigh-Tronix
Technical Specification
advanced multi-function indicator
Description
This specification describes the E1205 advanced multi-function weight indicator, capable of stand-alone operation, or of integration into a larger system via serial, FieldBus and Ethernet interfaces.
It is a microprocessor-based industrial weighing system with up to 100,000 displayed increments for analysing, displaying, storing and transmitting gross and net weight information.
E1205
E1205
Up to 12 load cells to be connected with the indicator (16 with second scale). Analogue load cells or Avery Weigh-Tronix digital load cells may be used.
This indicator can display weight data from two scales simultaneously. Both scales are active and are independently weighing at all times.
The E1205 can be matched to almost any load cell system to achieve optimum accuracy, stability and repeatability.
The indicator can control its surrounding process using fully configurable I/O. Alternatively, control can be executed from a central system using an extensive range of available interfaces.
Configurable Features
The E1205 features a dual purpose alpha-numeric keyboard which allows any of the following functions to be configured during commissioning:
Sensitivity to weight signal
Scale capacity
Number of divisions and
increment size
Weighing Unit
Zero/back balance
Decimal marker type - point or
comma
Position of decimal marker
Calibration site gravity factor
Customer site gravity factor
Filtering using FIR or
Harmonizer™ filtering systems
Ten points for linearity correction to ensure maximum accuracy
Tare availability and manner of operation
Time and date (two or four digit year, battery backed)
User-definable serial output strings
Subtotal and grand total information
Scale ID number
Alarm index operation
Recipe/filling I/O
configuration
1
E1205
Avery Weigh-Tronix Technical Specification
All these characteristics are stored in non-volatile memory so that once the ideal parameters for any given weighing system are established they can be retained with certainty for the future.
Once the scale is set up as required, a calibration report can be printed showing weighing details (useful for the installation engineer). This allows the state of the system to be monitored.
Up to 300 product look ups (PLUs) are available for instant recall of previously programmed product information.
Applications
Parts Counting
Sampling modes supported: fast; dribble; bulk
Static Checkweighing
Set limits, either absolute or relative to target. Set check­weigh bar step size.
In-Motion Checkweighing
The indicator can be used to control the in-motion process as required.
Peak Hold
Records maximum weight measured. Clear button resets memory
Weighbridge
A broad application, offering the following functions.
Three core operating modes -
Re-entered first weight
Stored and printed
Stored first weight
Additional modes:
Public weighing
Axle weighing (up to 10 axles)
Part loads
Two platform in/out operation
Simple stock control
Net weight adjustment (dirt
allowance)
Database supports:
Vehicles
Hauliers
Suppliers / Customers
Browsing
Outstanding vehicle report
Three Level Pack Run Monitoring
Set all parameters to monitor and manage the packing of components into boxes, and overpacking into cartons and onto pallets. Produce all labels as required for tracking.
Conversion Factor
Enter the factor required to convert to custom unit
Recipe/Filling
Control of complete process using fully configurable trips. In-flight compensation and dosing variables may be set to optimise the process. Batching mode allows repetition of the process for a defined quantity.
Totalising Against Dedicated Product Look Ups (PLUs)
Link weighings to PLUs for complete stock control.
Product List Description and Totalising
Create customised print-outs itemising customer transactions, with grand totals.
Type Through Mode
Allowing any text to be input on the E1210 and printed out in full on an attached printer or suitable computer system.
Terminal Mode
Giving enhanced PC control and power.
Remote Display Mode
Connect to, or use as a remote display.
Specification
Electrical
Display
Type
Blue back-lit LED. Graphics 64 x 240 pixels. Displays up to eight digits.
Decimal Points
Configurable to any of seven positions
Units Displayed
g, kg, lb(dec), lb oz, tons, tonnes, custom.
Annunciators
Balance (Gross Zero) Motion Pre-set Tare Semi-Automatic Tare Net lb or kg Print Three-off Trip Indicators Minus (below net zero) Scale 1 Scale 2
Keypad
28 keys, addressing: Alpha entry Numeric entry Five soft Function keys Dedicated Function Keys Zero, Tare, Select, Print, Units, Totals, Scale, PLU, Standby, Escape, Enter, Clear, Text
Remote IBM PS/2 keyboard input included (uses interface cable)
Load Cell Input
Analogue Input
Combined minimum load cell impedance must be greater than 22Ω.
Maximum Load Cells if 350 (One Scale)
12.
Total 350 Load Cells if 2nd Analogue Input Fitted
16.
2
Avery
Weigh-Tronix
Technical Specification
E1205
Connection of Input
Direct wired (Buccaneer if supplied stamped with scale).
Excitation
Direct current.
Voltage
10 V dc.
Current
Up to 460 mA
Remote Sense
Obtained from excitation, or Linked directly to reference input connectors at the indicator.
Input Impedance
1M paralleled with 2.2nF.
Signal
6-20 mV maximum.
uV/ per Division
0.6
Resolution
Approved 10,000 (OIML) Non- Approved 100,000
Calibration
Analogue to Digital
Convertor
Display Update Rate
1, 2, 5, 10 per second.
A to D Rate
120 per second.
A to D Type
Delta Sigma.
Filter
FIR & Dynamic Filtering
Seven programmable Options
Associated Filter Attributes
Filter Level Display Weight Noise Noise
Response Time Sample Rate Amplitude Frequency
(seconds) (Hz)
0 0.20 8.13 Lowest Highest
1 0.35 8.13
2 0.53 8.13
3 0.96 8.13
4 1.45 8.13
5 2.09 8.13
6 2.85 8.13 Highest Lowest
Full digital multi-point (ten point) calibration.
Theoretical calibration possible if parameters known.
Provides over load report.
Increment Multiplier
1, 2, 5,10, 20, 50, 100, 200, 500.
AVR
Three stage.
Gravity Compensation
Set gravity for calibration and installation site.
Dynamic Filter
Applied after the FIR filter. Set the filter window size in divisions (0 - 99). A high value will have a large damping effect on the weight display. This significantly slows the scale response to a legitimate change in weight.
Harmonizer™ Digital Filter
Three programmable parameters:
Samples to Average - sets number of A-D conversions which will be averaged to give a weight reading.
IIR Filter - sets how much damping the Harmonizer™ applies to the weight reading. Typically between 1 (low) - 8 (higher).
Balance/Zero
Setting
Keyboard push button.
Operation
Ignore or recall limit exceeded.
Size of Balance Range
Normally 4%, up to 100%.
Zero Indication
Within 4% of maximum capacity.
Under Range Indication
Displays ‘Under Range’.
Zero Tracking
Configurable
Motion Detection
Configurable.
Threshold Level - sets the minimum weight change (in calibration units) which the Harmonizer™ will not attempt to filter out as noise.
3
E1205
Avery Weigh-Tronix Technical Specification
Range/Span
Range of Adjustment
0 - 100,000 divisions.
Over Range Indication
Displays ‘Over Range’.
Tares
Three types of tares are available. Each is 100% subtractive.
Note: Interlocks between the tare types are configurable at time of commissioning.
Type A - Push-Button (Semi Auto) Tare
Push-button operated, semi­automatic, with selectable negative weight display. Cumulative taring is possible.
Initialisation and Operation
When the item to tare on is applied, press the ‘Tare’ push­button.
Indication
‘Net’ annunciator is illuminated.
Type B – Keyboard (Pre-set) Tare
Keyboard-entered tare operated with negative weight display.
Initialisation & Operation
Enter pre-set tare value using the 0-9 keypad and press ‘Tare’ push button. Multiple pre-set tares are possible.
Indication
‘Net’ annunciator is illuminated together with pre-set tare annunciator (PT).
Type C - Stored Tare
Stored tare operated with negative weight display allowing 40 separate stored tares. Will be retained when power is off.
Initialisation & Operation
Press ‘pre-set tare’ push button followed by the stored number ‘1’ to ‘40’ followed by ‘enter’ key. When two platforms are used, 20 stored tares are available for each platform.
Indication
‘Net’ icon is illuminated together with preset tare icon (PT).
Trips
The indicator has three internal trips as standard, and can support up to 16 external trips via external Trips Interface Units (see accessories). All trips (both internal and external) are rated at 240 V 10 A. Internal inputs are rated at TTL levels.
Two modes have independent control of the trip outputs, Alarm and Recipe. Alarm mode operates continuously. Recipe mode is dependant on the Recipe / Filling application being configured and in operation.
Alarm Mode
Alarm mode has 10 independent configurable indexes, and cannot be turned off. Each index can be programmed to operate any or all outputs based on a given target:
None - index inactive
Target Weight
Status of indicator, e.g. weight
steady, checkweigh accept
Input (single or specific pattern)
Output (single or specific pattern)
Time
Recipe /Filling Mode
Recipe/Filling mode has 20 configurable sequential steps, and is active only in Recipe/ Filling mode. Each recipe (maximum 100) can be configured independently to the others. Each index can be programmed to operate any or all outputs based on a given target:
None – index inactive
Target Weight (includes
tolerance, compensation and dosing parameters)
Status of indicator, e.g. weight steady, checkweigh accept
Input (single or specific pattern)
Output (single or specific pattern)
Time
Other variables that can be configured in Recipe / Filling mode are:
Outputs at start of step
Outputs at end of step
Target action (e.g. print)
PLU to accumulate totals data
All configuration information is retained when power is off.
Product Look Ups
(PLUs) & Totals
Information Stored per PLU
Sub-totals and grand totals. Application specific info stored per PLU. Memory protection of PLUs.
Maximum capacity of each PLU
999,999,999.
User Definable Text Fields per PLU
3, each 21 characters.
When a PLU is recalled, the indicator is automatically configured into the application programme of the PLU. All information on the PLU can be displayed as well as printed.
Real Time Clock
The E1205 is fitted with a real time clock which allows the user to display and print the time and date. This clock is battery-backed and will remain functional in the absence of mains power.
Communications
Serial Interface
Two bi-directional asynchronous serial interfaces (RS232/485/422 and RS232/20mA current loop) as standard. Two additional via optional digital interface card.
Networking
Ethernet 10/100 TCP/IP interface as standard.
Fieldbus interfaces – optional – see Kits.
4
Avery
Weigh-Tronix
Technical Specification
E1205
Electrical Power Input
Voltage
110 VAC - 230 VAC nominal, 50/60 Hz.
Tolerance
Voltage -15 to +10%. Frequency ±10%.
Power Consumption
30 VA maximum when used with full configuration of load cells.
Cable Length
2 m.
Power Supply
Internally fitted
Isolation Protection
None. Mains earth lead must be connected to safety earth.
Lightning protection external.
Mounting Options
The indicator will desk, wall or pole mount.
Pole mounting requires optional adapter.
Performance
Internal Resolution
16,777,216.
Repeatability
± 0.01% of full scale.
Span Drift Time
± 50 ppm/year max.
Span Drift Temperature
± 4 ppm/° C typical.
Zero Drift Time
± 10 ppm ±0.1% DL/year maximum.
Approvals
All data relating to the performance of the machine meets and exceeds requirements of EN 45501:1992 European Approval (‘E’ Approval) Accuracy Class III Machines and OIML 76-1. The type approval certificate numbers being:
EU - UK2694 South Africa ­New Zealand ­Australia -
Factory Options
Choice of mains power connector: UK, Euro, Australian, South African, American.
Environment
Resistance to Dirt and Moisture
Protected to IP54, in moulded plastic enclosure.
Electrical Disturbance
Immune to electrical disturbance, including RFI as detailed in EN 45501:1992
Operating Temperature
-10° C to + 40° C.
Service Temperature
-10° C to + 55° C.
Storage Temperature
-40° C to +70° C.
Finish
Enclosed in moulded ABS plastic case.
Zero Drift Temperature
± 2 ppm ± 40 ppm DL/ °C maximum.
Warm Up Time
Immediate self test complete.
Self Diagnostics
Graphics Display
Keys
PS/2 Keyboard
A2D (x 2)
Serial Test (4)
Network interface
Ethernet port
BCD Out
Analogue Out
Pulse In
Memory
Tally Roll
Internal I/O
External I/O
5
E1205
Avery Weigh-Tronix Technical Specification
Kits
The following kits are available to enable local configuration when required.
1. Analogue Card
Provides second analogue scale input and two analogue outputs 4-20 mA.
E11050F00000000
2. Digital Card
Provides two additional bi­directional asynchronous serial interfaces (RS232/485/422 and RS232). Also includes BCD output (range 1 - 100,000) and pulse input.
E11050G00000000
3. Electronic Tally Roll Card
Securely stores and prints up to 72,000 transactions, with details of scale ID, gross/tare/net weights, time, date and consecutive number. Also acts as carrier for FieldBus card.
E11050H00000000
8. ModBus TCP Interface Kit
Enables interfacing to ModBus TCP or Ethernet (over Modbus TCP) network. Includes Electronic Tally Roll card (
E11050H00000000
to provide interface.
) as standard
E11050N00000000
9. Load Cell Connector With
Internal Loom
When fitted, provides ability to disconnect load cell inputs from indicator without opening the unit.
70735-247
Accessories
1. External Lightning Protection Box
When fitted between the load cell/ junction box, and load cell input, provides protection from lightning.
E11050B00000000
2. Trips Interface Unit (TIU8)
Provides eight external I/O in place of three internal I/O included as standard. Inputs rated at 12 V, outputs rated at 240 V 10 A.
Two TIU8s may be connected to the E1210 to provide a total of 16 I/O.
E11100E00000000
3. 300 mm Pole
Stainless steel mounting pole with top mounting plate for indicator. E11100U00000000
4. 1000 mm Pole
Stainless steel mounting pole with top mounting plate for indicator
E11100V00000000
4. ProfiBus Interface Kit
Enables interfacing to ProfiBus network. Includes Electronic Tally Roll card ( standard to provide interface.
E11050H00000000
) as
E11050J00000000
5. ControlNet Interface Kit
Enables interfacing to ControlNet network. Includes Electronic Tally Roll card ( standard to provide interface.
E11050H00000000
) as
E11050K00000000
6. DeviceNet Interface Kit
Enables interfacing to DeviceNet network. Includes Electronic Tally Roll card ( standard to provide interface.
E11050H00000000
) as
E11050L00000000
7. Ethernet IP Interface Kit
Enables interfacing to Ethernet Industrial Protocol (IP) network. Includes Electronic Tally Roll card (
E11050H00000000
to provide interface.
) as standard
E11050M00000000
5. Interface Leads for Platform to Indicator
See price list.
6. Interface Leads for Indicator to Printer
See price list.
7. Y808
Large push button unit (up to four buttons).
6
Avery
Weigh-Tronix
Technical Specification
E1205
Weight
2.0 kg
Shipping Specification
Net
2.0 kg
Gross
4.6 kg
Measurement
345 mm x 270 mm x 335 mm
Harmonised Commodity Code
842390 00 0.
Dimensions
292
292
188
330
All dimensions in millimetres
7
E1205
Avery Weigh-Tronix Technical Specification
© Avery Berkel Limited 2004. All rights reserved. This publication is issued to provide outline information only which, unless agreed by Avery Berkel Limited in writing, may not be regarded as a representation relating
8
to the products or services concerned. Avery Berkel Limited reserves the right to alter without notice the specification, design, price or conditions of supply of any product or service.
E1205/4.04/Issue 1
Loading...