Avaya Serial Adapter Module Supplement User Manual

Part No. 303124-D Rev 00 December 2000
600 Technology Park Drive Billerica, MA 01821-4130
Serial Adapter Module
Supplement
Copyright © 2000 Nortel Networks
All rights reserved. December 2000. The information in this document is subject to change without notice. The statements, configurations, technical data,
and recommendations in this document are believed to be accurate and reliable, but are presented without express or implied warranty. Users must t ak e full re spo nsibility fo r th eir a pplic a tio ns of any products specif i ed in th is d ocume nt . The information in this document is proprietary to Nortel Networks NA Inc.
Trademarks
NORTEL NETWORKS is a trademark of Nortel Networks. AN and Passport are registered trademarks and Advanced Remote Node, ANH, ARN, BayRS, and BCC are
trademarks of Nortel Networks. Microsoft, MS, MS-DOS, Windows, and Windows NT are registered trademarks of Microsoft Corporation. All other trademarks and registered trademarks are t he property of their respective owners.
Statement of Conditions
In the interest of improvi ng internal design, operational fun c tion , an d/o r re liability , No rte l Networks NA Inc . rese rv e s the right to make changes to the products described in this document without notice.
Nortel Networks NA Inc. does not assume any liability that may occur due to the use or application of the product(s) or circuit layout(s) described herein.
USA Requirements Only
Federal Communications Commission (FCC) Compliance Notice: Radio Frequency Notice
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reaso nable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy. If it is not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required to take whatever measures may be necessary to correct the interference at their own expense.
European Requirements Only
EN 55 022 Statement
This is to certify that the Nortel Networks Serial Adapter Module is shielded against the generation of radio interference in accordance with the application of Council Directive 89/336/EEC, Article 4a. Conformity is declared by the application of EN 55 022 Class A (CISPR 22).
Warning: This is a Class A product. In a domestic environment, thi s produ c t may cau se radio in terf ere n ce, in whic h case, the user may be required to take appropriate measures.
Achtung: Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können be i B e trieb dieses Gerätes Rundfunkstörungen auftreten, in welchen Fällen der Benutzer für entsprechende Gegenmaßnahmen verantwortlich ist.
Attention: Ceci est un produit de Classe A. Dans un environnement domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à l’utilisateur de prendre les mesures spécifiques appropriées.
EC Declaration of Conformity
This product conforms (or these produc ts conform) to the provisions of Council Directive 89/336/EEC and 73/23/EEC.
303124-D Rev 00
Japan/Nippon Requirements Only
Voluntary Control Council for Interference (VCCI) Statement
Taiwan Requirements
Bureau of Standards, Metrology and Inspection (BSMI) Statement
Canada Requirements Only
Canadian Department of Communications Radio Interference Regulations
This digital apparatus (Serial Adapter Module) does not exceed the Class A limits for radio-noise emissions from digital apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications.
Règlement sur le brouillage radioélectrique du ministère des Communications
Cet appareil numérique (Serial Adapter Module) respecte les limites de bruits radioélectriques visant les appareils numériques de classe A prescrites dans le Règlement sur le brouillag e radioélectrique du m inistère des Communications du Canada.
Canada CS-03 Rules and Regulations
Notice: The Industry Canada label identifies certified equipment. This certification means that the equipment meets telecommunications netw ork prote cti ve, opera tional and safety re quirements as pres cribed in the app ropriate Term inal Equipment Technical Requirements document(s). The Department does not guarantee the equipment will operate to the user’s satisfaction.
Before installing this equipment, u sers shou ld e nsure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an a cceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent the degradation of service in some situations.
303124-D Rev 00
iii
Canada Requirements Only
Repairs to certified equipment should be coo rdinated by a representative designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.
Users should ensure for their own protection tha t the electrical gro und connecti ons of the po wer utility, tele phone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.
Caution: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electric ia n, as appro p ria te.
Notice: For equipment using loopstart lines, please note that the Ringer Equivalence Number (REN) assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed 5. The REN is located on the “FCC Rules Part 68” label located on the bracket of the module, or on the back of the unit.
Canada CS-03 -- Règles et règlements
Avis: L'étiquette d'Industrie Canada identifie le matériel homologué. Cette étiquette certifie que le matériel est conforme aux normes de protection, d'exploitation et de sécurité des réseaux de télécommunications, comme le prescrivent les documents concernant les exigences techniques relatives au matériel terminal. Le Ministère n'assure toutefois pas que le matériel fonctionnera à la satisfaction de l'utilisateur.
Avant d'installer ce matériel, l'utilisateur doit s'assurer qu'il est permis de le raccorder aux installations de l'entreprise locale de télécommunication. Le matériel doit également être installé en suivant une méthode acceptée de raccordement. L'abonné ne doi t pas oublier qu'il est possible que l a conformité aux conditions énoncées ci-dessus n'empêche pas la dégradation du service dans certaines situations.
Les réparations de matériel homologué doivent être coordonnées par un représentant désigné par le fournisseur. L'entreprise de télécomm unication s pe ut d emande r à l' utilisat eur de débra ncher u n app areil à la su ite de rép arations o u de modifications effectuées par l'utilisateur ou à cause de mauvais fonctionnement.
Pour sa propre protectio n, l 'utilisateur doit s'assurer que tous les f ils d e mise à la te rre de la sou rce d 'éner gie électriqu e, des lignes téléphoniques et des canalisations d'eau métalliques, s'il y en a, sont raccordés ensemble. Cette précaution est particulièrement importante dans les régions rurales.
Avertissement: L'utilisateur ne d oi t p as ten ter d e f a ire c es racco rde m ents lu i-m ême; i l do it avoir recour s à un se rvice d'inspection des installati ons électriques, ou à un électricien , selon le cas.
Avis: Veuillez prendre note que pour tout appareillage supportant des lignes de type “loopstart,” l'indice d'équivalence de la sonnerie (IES) assigné à chaque dispositif terminal indique le nombre maximal de terminaux qui peuvent être raccordés à une interface. La terminaison d'une interface téléphonique peut consister en une combinaison de quelques dispositifs, à la seule condition q ue la somme d'indi ces d'équi v alence de la sonnerie de to us les dispositifs n' excède p as
5. Le REN figure sur l’étiquette “FCC Rules Part 68” située sur le support du module ou à l’arrière de l’unité.
(continued)
iv
303124-D Rev 00
FCC Part 68 Compliance Statement
This equipment complies with Pa rt 68 of FCC Ru les. All dire ct c onnec tio ns to telep hone ne tw o r k line s mu st be mad e using standard plugs and jacks compliant with FCC Part 68. Please note the following:
1. You are required to request service from the telephone company before you connect the unit to a network. When you request service, you must pro vide the teleph on e compa ny with the following data:
When you request T1 Service, you must provide the telephone company with
-- The Facility Interface Code Provide the telephone company with all the codes below:
- 04DU9-BN (1.544 MB, D4 framing format)
- 04DU9-DN (1.544 MB, D4 framing format with B8ZF coding)
- 04DU9-1KN (1.544 MB, ESF framing format)
- 04DU9-1SN (1.544 MB, ESF framing format with B8ZF coding)
- 04DU9-1ZN (1.544 MB, ANSI ESF and ZBTSI without line power) The telephone company will select the code it has available.
-- The Service Order Code(s) (SOC): 6.0F
-- The req uired Universal Service Order Code (USOC) jack: RJ48C
When you request Primary Rate ISDN Service, you must provide the telephone company with
-- The Facility Interface Code: 04DU9-1SN (1.544 MB, ESF framing format with B8ZF coding)
-- The Service Order Code(s) (SOC): 6.0F
-- The req uired Universal Service Order Code (USOC) jack: RJ48C
2. Your telephone company may make changes to its facilities, equipment, operations, or procedures that could affect the proper function in g of yo ur equip m ent. The teleph on e com pany will notify you in advan ce of suc h changes to give you an opportunity to maintain uninterrupted telephone service.
3. If the unit causes harm to the telephone network, the telephone company may temporarily discontinue your service. If possible, they will notify you in advance, but if advance notice is not practical, you will be notified as soon as possible and will be informed of your right to file a complaint with the FCC.
4. If you experience trouble with the unit, pl ease contact the Nortel Networks Technical Solutions Center in your area for service or rep a irs. Repairs should be per f or med only by service person nel authorized by Nortel Networks.
United States 1-800-2LANWAN Valbonne, France 33-4-92-96-69-68 Sydney, Australia 61-2-9927-8800 Tokyo, Japan 81-3-5740-1700
5. You are required to notify the telephone company when you disconnect the unit from the network.
303124-D Rev 00
v
Nortel Networks NA Inc. Software License Agreement
NOTICE: Please carefully read this license agre ement before copying or using the accompanying software or installing the hardware unit with pre-enabled software (each of which is referred to as “Software” in this Agreement). BY COPYING OR USING THE SOFTWARE, YOU ACCEPT ALL OF THE TERMS AND CONDITIONS OF THIS LICENSE AGREEMENT. THE TERMS EXPRESSED IN THIS AGREEMENT ARE THE ONLY TERMS UNDER WHICH NORTEL NETWORKS WILL PERMIT YOU TO USE THE SOFTWARE. If you do not accept these terms and conditions, return the product, unused and in the original shipping container, within 30 days of purchase to obtain a credit for the full purchase price.
1. License grant. Nortel Networks NA Inc. (“Nortel Networks”) grants the end user of the Software (“Licensee”) a
personal, nonex clusive, nontransfera ble lic ense: a) to use the Softw are eit her on a sing le compu ter or, if applicab le, o n a single authorized device identified by host ID, for which it was originally acqui red; b) to copy the Software solely for backup purposes in support of authorized use of the Software; and c) to use and copy the associated user manual solely in support of autho rized us e of the So ftw are by Licensee. Th is license a pplies to th e Softwa re only a nd does not extend to Nortel Networks Agent software or other Nortel Networks software products. Nortel Networks Agent software or other Nortel Networks software products are licensed for use under the terms of the applicable Nortel Networks NA Inc. Software License Agreement that accompanies such software and upon payment by the end user of the applicable license fees for such software.
2. Restrictions on use; reservation of rights. The Software and user manuals are protected under copyright laws.
Nortel Networks and/or its licensors retain all title and ownership in both the Software and user manuals, including any revisions made by Nortel Networks or its licensors. The copyright notice must be reproduced and included with any copy of any portion of the Software or user manuals. Licensee may not modify, translate, decompile, disassemble, use for any competitive analysis, reverse engineer, distribute, or create derivative works from the Software or user manuals or any copy, in whole or in part. Except as expressly provided in this Agreement, Licensee may not copy or transfer the Software or user manuals, in whole or in part. The Software and user manuals embody Nortel Networks’ and its licensors’ confidential and propriet ary in te llec tu al pro p erty. Licensee shall not sublicense, assign, or otherwise disclose to any third party the Software, or any information about the operation, design, performance, or implementation of the Software and user manuals that is confidential to Nortel Networks and its licensors; however, Licensee may grant permission to its consultants, subcontractors, a nd agents to use the Softw are at Licensee’s facility, provided they have agreed to use the Software only in accordance with the terms of this license.
3. Limited warranty . Nortel Networks warrants each item of Software, as delivered by Nortel Networks and properly
installed and operated on Nortel Networks hardware or other equipment it is originally licensed for, to function substantially as described in its accompanying user manual during its warranty period, which begins on the date Software is first shipped to Licensee. If an y item of S oftware f ails to so function d uring its w arranty period, as the sole remedy Nortel Networks will at its discretion provide a suitable fix, patch, or workaround for the problem that may be included in a future Software release. Nortel Networks further warrants to Licensee that the media on which the Software is provided will be free from defec ts in materials and wo rkman ship under no rmal use for a peri od of 90 da ys from the date Software is first shipped to Licensee. Nortel Networks will replace defective media at no charge if it is returned to Nortel Netw orks during the warranty period along with pro of of the date of shipment. This warranty does not apply if the media has been damaged as a result of accident, misuse, or abuse. The Licensee assumes all responsibility for selection of the Software to achieve Licensee’s intended results and for the installation, use, and results obtained from the Software. Nortel Networks does not warrant a) that the functions contained in the software will meet the Licensee’s requirements, b) that the Software will operate in the hardware or software combinations that the Licensee may select, c) that the operation of the Software will be uninterrupted or error free, or d) that all defects in the operation of the Softw are will be corrected . Nortel Network s is not obligated to remedy any Software de fect that cannot be reproduced with the latest Software release. These warranties do not apply to the Software if it has been (i) altered, except by Nortel Networks or in accordance with its instructions; (ii) used in conjunction with another vendor’s product, resulting in the de fect; or (iii) damaged by improper environment, abuse, misu se, accident, or negligence. THE FOREGOING WARRANTIES AND LIMITATIONS ARE EXCLUSIVE REMEDIES AND ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITAT ION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Licensee is responsible
vi
303124-D Rev 00
for the security of its own data and information and for maintaining adequate procedures apart from the Software to reconstruct lost or altered files, data, or programs.
4. Limitation of liability. IN NO EVENT WILL NORTEL NETWORKS OR ITS LICENSORS BE LIABLE FOR
ANY COST OF SUBSTITUTE PROCUREMENT; SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES; OR ANY DAMAGES RESULTING FROM INACCURATE OR LOST DATA OR LOSS OF USE OR PROFITS ARISING OUT OF OR IN CONNECTION WITH THE PERFORMANCE OF THE SOFTWARE, EVEN IF NORTEL NETWORKS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. IN NO EVENT SHALL THE LIABILITY OF NORTEL NETWORKS RELATING TO THE SOFTWARE OR THIS AGREEMENT EXCEED THE PRICE PAID TO NORTEL NETWORKS FOR THE SOFTWARE LICENSE.
5. Government licensees. This provision applies to all Software and documenta tion acqu ired direc tly or indi rectly by
or on behalf of the United States Government. The Software and documentation are commercial products, licensed on the open market at market prices, and were developed entirely at private expense and without th e use of any U.S. Government funds. The license to the U.S. Government is granted only with restricted rights, and use, duplication, or disclosure by the U.S. Government is subject to the restrictions set forth in subparagraph (c)(1) of the Commercial Computer Software––Restricte d Rig hts cla u se o f FAR 52.227-19 and the limitations set out in thi s license for civilian agencies, and subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause of DFARS
252.227-7013, for agencies of t he Department of Defense or their successors, whichever is applicable.
6. Use of software in the European Community. This provision applies to all Software acquired for use within the
European Community. If Licensee uses the Software within a country in the European Community, the Software Directive enacted by the Council of European Commun ities Directive dated 14 May, 1991, will apply to the examination of the Software to facilitate interoperability. Licensee agrees to notify Nortel Networks of any such intended examination of the Software an d may procure support and assistance from Nortel Networks.
7. Term and termination. This license is effective until terminated; however, all of the restrictions with respect to
Nortel Networks’ copyright in the Software and user manuals will cease being effective at the date of expiration of the Nortel Networks copyright; those restrictions relating to use and disclosure of Nortel Networks’ confidential information shall continue in effect. Licensee may terminate this license at any time. The license will automatically terminate if Licensee fails to comply with any of the terms and conditions of the license. Upon termination for any reason, Licensee will immediat ely destroy or return to Nortel Networks the Software, user manuals, and all copies. Nortel Networks is not liable to Licensee for damages in any form solely by reason of the termination of this license.
8. Export and re-export. Licensee agrees not to export, directly or in directly, the Software or related technical data or
information without f irst obtain ing a n y required e xport lice nses or oth er go v ernme ntal ap pro v als. W i thout limiting the foregoing, Lice n see, on behalf of itse lf an d its subsidiaries and affiliate s, a gr ees t hat it will not, without first obtaining all export licenses and approvals required by the U.S. Government: (i) export, re-export, transfer, or divert any such Software or technical data, or any direct product thereof, to any country to which such exports or re-exp orts are restricted or embargoed under United States export control laws and regulations, or to any national or resident of such restricted or embargoed countries; or (ii) provide the Software or related technical data or information to any military end user or for any military end use, including the design, development, or production of any chemical, nuclear, or biological weapons.
9. General. If any provision of this Agreement is held to be invalid or unenforceable by a court of competent
jurisdiction, the remainder of the provisions of this Agreement shall remain in full force and effect. This Agreement will be governed by the laws of the state of California.
Should you have any questions concerning this Agreement, contact Nortel Networks, 4401 Great America Parkway, P.O. Box 58185, Santa Clara, California 95054-8185.
LICENSEE ACKNOWLEDGES THAT LICENSEE HAS READ THIS AGREEMENT, UNDERSTANDS IT, AND AGREES TO BE BOUND BY ITS TERMS AND CONDITIONS. LICENSEE FURTHER AGREES THAT THIS AGREEMENT IS THE ENTIRE AND EXCLUSIVE AGREEMENT BETWEEN NORTEL NETWORKS AND LICENSEE, WHICH SUPERSEDES ALL PRIOR ORAL AND WRITTEN AGREEMENTS AND COMMUNICATIONS BETWEEN THE PARTIES PERTAINING TO THE SUBJECT MATTER OF THIS AGREEMENT. NO DIFFERENT OR ADDITIONAL TERMS WILL BE ENFORCEABLE AGAINST NORTEL NETWORKS UNLESS NORTEL NETWORKS GIVES ITS EXPRESS WRITTEN CONSENT, INCLUDING AN EXPRESS WAIVER OF THE TERMS OF THIS AGREEMENT.
303124-D Rev 00
vii

Contents

Preface
Before You Begin ............................................................................................................. xv
How to Use This Supplement .......................................................................................... xv
Text Conventions .............................................................................................................xvi
Acronyms ........................... .......................... .......................... ......................... .................x vi
Hard-Copy Technical Manuals .................................................................. ...... ....... ...... ...xvii
How to Get Help .............................................................................................................xvii
Chapter 1 Using the Serial Adapter Module in an AN or an ANH Router
Verifying AN/ANH Router Requirements ..................................... ...... ....... ...... ....... ...... ...1-1
Attaching Cables ............................................................................................................1-2
Completing Software Configuration ................................................................................1-3
Interpreting LEDs ...........................................................................................................1-4
Chapter 2 Using the Serial Adapter Module in a Passport ARN Router
Verifying ARN Router Requirements ..............................................................................2-1
Attaching Cables ............................................................................................................2-2
Completing Software Configuration ................................................................................2-3
Interpreting LEDs ...........................................................................................................2-4
Chapter 3 Using the Serial Adapter Module in a Passport 5430 Multiservice Access Switch
WAN Adapter Module Placement Considerations ..........................................................3-1
Attaching Cables ............................................................................................................3-3
Completing Software Configuration ................................................................................3-4
Interpreting LEDs ...........................................................................................................3-5
303124-D Rev 00
ix
Chapter 4 Using the Serial Adapter Module in a Passport 2430 Multiservice Access Switch
Attaching Cables ............................................................................................................4-1
Completing Software Configuration ................................................................................4-3
Interpreting LEDs ...........................................................................................................4-4
x
303124-D Rev 00

Figures

Figure 1-1. Serial Adapter Module Connector on an AN or 12-Port ANH ..................1-2
Figure 1-2. Serial Adapter Module Connector on an 8-Port ANH ..............................1-2
Figure 1-3. Serial Adapter Module RLSD LED ...........................................................1-4
Figure 2-1. ARN Serial Adapter Module Connector (Slot 2) ......................................2-2
Figure 2-2. Serial Adapter Module RLSD LED ...........................................................2-4
Figure 3-1. Passport 5430 Serial Adapter Module Connector ...................................3-4
Figure 3-2. Serial Adapter Module RLSD LED ...........................................................3-5
Figure 4-1. Passport 2430 Serial Adapter Module Connector ...................................4-2
Figure 4-2. Serial Adapter Module RLSD LED ...........................................................4-4
303124-D Rev 00
xi

Tables

Table 1-1. PROM Diagnostic and Boot Code for AN/ANH Routers ..........................1-1
Table 2-1. PROM Diagnostic and Boot Code for ARN Routers ................................2-1
Table 3-1. Example WAN Adapter Module Combinations ........................................3-2
303124-D Rev 00
xiii
The Serial Adapter Module provides connectivity for V.35, RS-232, RS-449/422 balanced, RS-530, and X.21 devices.

Before You Begin

This guide is inten ded f or qual ifie d se rvice personn el who are ins tall ing th e Ser ial Adapter Module in an AN 2430 for the first time or who need to install or replace any customer-replaceable unit (CRU). A qualified s er vic e pe rs on should have appropriat e t ec hni cal tr ai ni ng and experience and be aware of the hazards involved in installing and replacing CRUs.

Preface

®
/ANH™, Passport® ARN™, Passport 5430, or Passport

How to Use This Supplement

This WAN adapter module can be used with several different platforms. Refer to the table belo w to find the chapter th at contains th e information a ppropriate for t he platform you are using.
Platform Refer to
AN or ANH Chapter 1 Passport ARN Chapter 2 Passport 5430 Chapter 3 Passport 2430 Chapter 4
303124-D Rev 00
xv
Serial Adapter Module
Supplement

Text Conventions

This guide uses the following text conventions:

Acronyms

bold text
italic text Indicates new terms, book titles, and variables in
This guide uses the following acronyms:
BRI basic rate interface CRU customer-replaceable unit ESD electrostatic discharge IP Internet Pr otocol ISDN Integrated Services Digital Network LED light-emitting diode PROM programmable read-only memory
Indicates command names and options and text that you need to enter.
diags
Example: Enter the
command syntax descriptions.
command.
xvi
RSL received line signal detection WAN wide area network
303124-D Rev 00

Hard-Copy Technical Manuals

You can print selected technical manuals and release notes free, directly from the Internet. Go to the support.baynetworks. com/library/ tpubs/ URL. Find the p roduct for which you need documentation. Then locate the specific category and model or version for your hardware or software product. Use Adobe Acrobat Reader to open the manuals and release notes, search for the sections you need, and print them on most standard printers. Go to Adobe Systems at www.adobe.com to download a free copy of Acrobat Reader.
You can purchase selected documentation sets, CDs, and technical publications through the Internet at the www1.fatbrain.com/documentation/nortel/ URL.

How to Get Help

If you purchased a service contract for your Nortel Networks product from a distributor or authorized reseller, contact the technical support staff for that distributor or reseller for assistance.
Preface
If you purchased a Nort el Net w orks s ervic e program, c ontact on e of th e fol lo win g Nortel Networks Technical Solutions Centers:
Technical Solutions Center Telephone
EMEA (33) (4) 92-966-968 North America (800) 2LANWAN or (800) 252-6926 Asia Pacific (61) (2) 9927-8800 China (800) 810-5000
An Express Routing Code (ERC) is available for many Nortel Networks products and services. When you use an ERC, your call is routed to a technical support person who specializes in supp orting that product or service. To locate an ERC for your product or service, go to the www12.nortelnetworks.com/ URL and click ERC at the bottom of the page.
303124-D Rev 00
xvii
Using the Serial Adapter Module in an
AN or an ANH Router
This chapter supplements Installing an Adapter Module in an AN or ANH Router. Follow the hardware installation steps in that manual, then refer to this document for information specific to the serial adapter module.

Verifying AN/ANH Router Requirements

Chapter 1
Table 1-1 shows the minimum versions of boot and diagnostic programmable
read-only memory (PROM) code required for a serial adapter module.
Table 1-1. PROM Diagnostic and Boot Code for AN/ANH Routers
Code Type Minimum Version Directory File Name
Boot 8.12 Diagnostic 5.31
For information on upgrading PROM, see the BayRS
an_proms anboot.exe an_proms andiag.exe
Upgrading Routers guide.
303124-D Rev 00
1-1
Serial Adapter Module
Supplement

Attaching Cables

Connect the communicatio ns cable to th e 44-pin DSUB connector on the insta lled adapter module.
You install the serial adapter module in an ope n adapter module slot on the router, as follows:
AN or 12-port ANH -- the back-panel adapter module slot (Figure 1-1 See Installing an Adapter Module in an AN or ANH Router.
8-port ANH -- the back-panel COM3 slot (Figure 1-2
).
See Installing an Adapter Module in an AN or ANH Router.
XCVR
UTP
CONSOLE
TX RX CL
RST
RLSD2
Third synchronous
interface
Figure 1-1. Serial Adapter Module Connector on an AN or 12-Port ANH
COM 2
COM 1
RLSD1
U
L
U
L
100-240V
50-60 Hz
1.0-0.5A
AN0133A
).
COM 2
COM 3/Expansion
Third synchronous
interface
Figure 1-2. Serial Adapter Module Connector on an 8-Port ANH
1-2
COM 1
ANH137A
303124-D Rev 00
Using the Serial Adapter Module in an AN or an ANH Router

Completing Software Configurat ion

Once you have successfully installed the serial adapter module, complete the following software configuration tasks using instructions found in your BayRS documentation:
Configuration Task Location of Instructions
Connect the AN or ANH to the network.
Modify the configuration file to add the serial adapter module and enable default software services.
Configure line services. Configure WAN protocol services. Any of the BayRS WAN or System Suite
Installing and Operating AN and ANH Routers
Any of the following:
Configuring and Managing Rou ters with Site Manager
Using the Bay Command Console (BCC)
Configuring WAN Line Services
guides, including:
Configuring IP Services
Configuring Frame Relay Services
Configuring X.25 Servi c es
Configuring PPP Services
For the latest information, be sure to review the release notes and documentation change notice for your version of BayRS software.
303124-D Rev 00
1-3
Serial Adapter Module
Supplement

Interpreting LEDs

The serial adapter module
(Figure 1-3)
RLSD
Figure 1-3. Serial Adapter Module RLSD LED
Note:
lights when the serial interface detects data transfer.
The LED will blink on and off during diagnostic testing, but does not
RLSD (Received Line Signal Detection) LED
COM
Serial
ARN0108A
indicate data transfer until you have configured and enabled the software services.
1-4
303124-D Rev 00
Using the Serial Adapter Module in a
Passport ARN Router
This chapter supplements Installing and Operating Passport ARN Routers (Chapter 4, “Installing a WAN Adapter Module”). Follow the hardware installation steps in that manual, then refe r to this docume nt for informat ion specific to the serial adapter module.

Verifying ARN Router Requirements

Chapter 2
303124-D Rev 00
Table 2-1 shows the minimum versions of boot and diagnostic programmable
read-only memory (PROM) code required for a serial adapter module.
Table 2-1. PROM Diagnostic and Boot Code for ARN Routers
Code Type Minimum Version Directory File Name
Boot 1.17 Diagnostic 1.30
For information on upgrading PROM, see the BayRS
arn_proms arnboot.exe arn_proms arndiag.exe
Upgrading Routers guide.
2-1
Serial Adapter Module
Supplement

Attaching Cables

Connect the communicatio ns cable to th e 44-pin DSUB connector on the insta lled adapter module.
You install the serial adapter module in one of the two front-panel WAN adapter module slots (Figure 2-1)
1
2
RLSD
U
ISDN BRI
with NT1
.
ARN front panel
10BaseT
D
B1
DD
B2
COM
Tx
Rx
Cl
Ethernet 2
10BaseT
Tx
Rx
Cl
Ethernet 1
2-2
To RS-232, RS-422, RS-530, V.28, V.35, or X.21 interface
ARN0066A
Figure 2-1. ARN Serial Adapter Module Connector (Slot 2)
303124-D Rev 00
Using the Serial Adapter Module in a Passport ARN Router

Completing Software Configurat ion

Once you have successfully installed the serial adapter module, complete the following software configuration tasks using instructions found in your BayRS documentation:
Configuration Task Location of Instructions
Connect the ARN to the network. One of the following:
Modify the configuration file to add the serial adapter module and enable default software services.
Configure line services. Configure WAN protocol services. Any of the BayRS WAN or System Suite
Installing and Operating Passport ARN Routers
Configuring Remote Access for AN and ANH Routers
Any of the following:
Configuring and Managing Rou ters with Site Manager
Using the Bay Command Console (BCC)
Configuring WAN Line Services
guides, including:
Configuring IP Services
Configuring Frame Relay Services
Configuring X.25 Servi c es
Configuring PPP Services
303124-D Rev 00
For the latest information, be sure to review the release notes and documentation change notice for your version of BayRS software.
2-3
Serial Adapter Module
Supplement

Interpreting LEDs

The serial adapter module
(Figure 2-2)
RLSD
Figure 2-2. Serial Adapter Module RLSD LED
Note:
lights when the serial interface detects data transfer.
The LED will blink on and off during diagnostic testing, but does not
RLSD (Received Line Signal Detection) LED
COM
Serial
ARN0108A
indicate data transfer until you have configured and enabled the software services.
2-4
303124-D Rev 00
Using the Serial Adapter Module in a
Passport 5430 Multiservice Access Switch
This chapter supplements Installing and Operating the Passport 5430 Multiservice Access Switch (Chapter 10, “Installing a WAN Adapter Module”).
Follow the hardware installation steps in that manual, then refer to this document for information specific to the serial adapter module.

WAN Adapter Module Placement Considerations

Chapter 3
303124-D Rev 00
When installing WAN adapter modules in the Passport 5430 Module slots, note the following:
Each WAN adapter module you install is automatically assigned a circuit, even if the WAN adapter module has not been configured. This prevents disruption of active circuits if you reconfigure the the module at a later time.
ISDN BRI adapter modules can use two circuits (one for each of the 2 B channels).
You can configure a total of 4 circuits.
Circuit allocations are prioritized according to which Module slot is being used by the WAN adapter modules. Module slot 3 has priority over Module slot 4, and Module slot 4 has priority over Module slot 5.
When there are more than the 4 possible circuits to be configured, for example if there are 2 ISDN BRI adapter modules and a serial adapter module (5 circuits in all), circuit allocation becomes an issue.
3-1
Serial Adapter Module
In the example above, the first ISDN BRI module (in Module slot 3) has the resources to bring up a second B channel ( thus usin g 2 circui ts). The s erial adapt er in Module slot 4 uses a third circuit. The second ISDN BRI adapter module (in Module slot 5), can have only 1 B channel configured because the serial adapter module (in Module slot 4) has priority and is allocated a circuit over anything in Module slot 5. In this case, there are not enough circuits left to utilize the second B channel on the ISDN BRI adapter in Module slot 5. In this example, if you wanted to have both B channels on both ISDN BRI adapters configured, you would have to remove the serial card from Modu le slot 4.
Supplement
Table 3-1
lists examples of valid WAN adapter module combinations.
Table 3-1. Example WAN Adapter Module Combinations
Module 3 Module 4 Module 5
T1/FT1 or E1/FE1 T1/FT1 or E1/FE1 T1/FT1 or E1/FE1 T1/FT1 or E1/FE1 T1/FT1 or E1/FE1 Serial or V.34 modem T1/FT1 or E1/FE1 Serial or V.34 modem Serial or V.34 modem T1/FT1 or E1/FE1 T1/FT1 or E1/FE1 ISDN 2 B-channels plus 1
D-channel
T1/FT1 or E1/FE1 ISDN BRI 1 B-channel plus 1
D-channel T1/FT1 or E1/FE1 Serial or V.34 modem Serial or V.34 modem Serial or V.34 modem Serial or V.34 modem Serial or V.34 modem Serial or V.34 modem Serial or V.34 modem ISDN BRI 1 B-channel plus 1
Serial or V.34 modem Serial or V.34 modem ISDN BRI 2 B-channels plus 1
Serial or V.34 modem ISDN BRI 2 B-channels plus 1
D-channel ISDN BRI
2 B-channels plus 1 D-channel
ISDN BRI 2 B-channels plus 1 D-channel
ISDN BRI 2 B-channels p lus 1
D-channel
ISDN BRI 1 B-channel pl us 1
D-channel
Serial or V.34 modem
D-channel
D-channel ISDN BRI 1 B-channel plus 1
D-channel Empty
Serial or V.34 modem
(continued)
3-2
303124-D Rev 00
Using the Serial Adapter Module in a Passport 5430 Multiservice Access Switch
Table 3-1. Example WAN Adapter Module Combinations (continued)
Module 3 Module 4 Module 5
ISDN BRI 2 B-channels plus 1 D-channel
ISDN BRI 2 B-channels plus 1 D-channel
ISDN BRI 2 B-channels plus 1 D-channel

Attaching Cables

Connect the communicatio ns cable to th e 44-pin DSUB connector on the insta lled adapter module.
You install the serial adapter module in one of the three front-panel Module slots on the Passport 5430 (Figure 3-1)
Note:
The slot labeled Remote Console is reserved for the V.34 modem adapter module. Do not install the serial adapter module in the Remote Console slot.
ISDN BRI 1 B-channel pl us 1 D-channel
Serial or V.34 modem ISDN BRI 1 B-channel plus 1
T1/FT1 or E1/FE1 ISDN BRI 1 B-channel plus 1
T1/FT1 or E1/FE1
D-channel
D-channel
.
303124-D Rev 00
3-3
Serial Adapter Module
Supplement
Module 3
Module 4
Module 5
Remote Console
U
ISDN BRI
with NT1
Telco
V.34 Modem
Telco
V.34 Modem
COM
To RS-232,RS-422,RS-530, V.28,V.35,or X.21interface
Figure 3-1. Passport 5430 Serial Adapter Module Connector

Completing Software Configurat ion

Once you have successfully installed the serial adapter module, complete the following software configuration tasks using instructions found in your BayRS documentation:
FBR0022A
3-4
Configuration Task Location of Instructions
Modify the Passport 5430 configuration file to add the serial adapter module and enable default software services.
Any of the following:
Configuring and Managing Rou ters with Site Manager
Using the Bay Command Console (BCC)
Configure line services.
Configuring WAN Line Services
Configure WAN protocol services. Any of the BayRS WAN or System Suite
guides, including:
Configuring IP Services
Configuring Frame Relay Services
Configuring X.25 Servi c es
Configuring PPP Services
303124-D Rev 00
Using the Serial Adapter Module in a Passport 5430 Multiservice Access Switch
For the latest information, be sure to review the release notes and documentation change notice for your version of BayRS software.

Interpreting LEDs

The serial adapter module
(Figure 3-2)
RLSD
Figure 3-2. Serial Adapter Module RLSD LED
Note:
lights when the serial interface detects data transfer.
The LED will blink on and off during diagnostic testing, but does not
RLSD (Received Line Signal Detection) LED
COM
Serial
ARN0108A
indicate data transfer until you have configured and enabled the software services.
303124-D Rev 00
3-5
Passport 2430 Multiservice Access Switch
This chapter supplements Installing and Operating the Passport 2430 Multiservice Access Switc h . F ollow the hardw are insta llat ion steps in that ma nual,
then refer to this document for information specific to the serial adapter module.

Attaching Cables

Chapter 4
Using the Serial Adapter Module in a
Connect the communicatio ns cable to th e 44-pin DSUB connector on the insta lled adapter module.
You install the serial adapter module in one of the WAN adapter module slots on the Passport 2430 (Figure 4-1)
.
303124-D Rev 00
4-1
Serial Adapter Module
Supplement
1
COM
To RS-232,RS-422,RS-530, V.28,V.35,or X.21interface
VLK0029A
4-2
Figure 4-1. Passport 2430 Serial Adapter Module Connector
303124-D Rev 00
Using the Serial Adapter Module in a Passport 2430 Multiservice Access Switch

Completing Software Configurat ion

Once you have successfully installed the serial adapter module, complete the following software configuration tasks using instructions found in your BayRS documentation:
Configuration Task Location of Instructions
Connect the Passport 2430 to the network.
Modify the configuration file to add the serial adapter module and enable default software services.
Configure line services. Configure WAN protocol services. Any of the BayRS WAN or System Suite
Installing and Operating the Passport 2430 Multis ervice Ac cess Switch
One of the following:
Configuring and Managing Rou ters with Site Manager
Using the Bay Command Console (BCC)
Configuring WAN Line Services
guides, including:
Configuring IP Services
Configuring Frame Relay Services
Configuring X.25 Servi c es
Configuring PPP Services
For the latest information, be sure to review the release notes and documentation change notice for your version of BayRS software.
303124-D Rev 00
4-3
Serial Adapter Module
Supplement

Interpreting LEDs

The serial adapter module
(Figure 4-2)
RLSD
Figure 4-2. Serial Adapter Module RLSD LED
Note:
lights when the serial interface detects data transfer.
The LED will blink on and off during diagnostic testing, but does not
RLSD (Received Line Signal Detection) LED
COM
Serial
ARN0108A
indicate data transfer until you have configured and enabled the software services.
4-4
303124-D Rev 00
Loading...