BCM200/400 Installation and Maintenance Guide

Page 87, Analog media bay modules

The GASM8 is designated as an ONS (on-premise station) port.

Page 87, Analog media bay modules

The information on regional availability is modified:
The ASM8 is available in North America only; the ASM8+ and GASM8 are available in North America, the United Kingdom, Australia, and Poland.

Page 95, 7406 digital phone system components

The second bullet, "Portable handsets: based on T316 functionality, including six line buttons and a two-line display,"
should be, "Portable handsets: based on T7316 functionality, including six line buttons and a two-line display."
Business Communications Manager
2

Page 164, Connect the media bay modules to service providers

In Figure 80, the pinout diagram is changed.
Figure 80 BRIM S/T RJ45 wiring array
BRIM S/T connector
Pin #/connection System side
1 not used 2 not used 3 +Rx 4 +Tx 5 -Tx 6 -Rx 7 not used 8 not used
1 2 3 4 5 6 7 8
8 7 6 5 4 3 2 1
RJ45 jacks
+Tx +Rx
-Rx
-Tx

Page 327, Analog media bay modules

The sentence, "The ATA2 provides on-premise service only (unexposed plant only),"
should be, "The ATA2 is designated as either an ONS (on-premise station) or an OPS (off-premise station) port."

Page 329, Connecting an analog telephone

In Figure 183, the label "BCM1000" is changed to "BCM200/400".
Figure 183 Analog telephone installation overview
ATA 2 power cord
BCM200/400 Central Office
ATA 2
Line loop resistance: 135 ohms maximum
Analog telephone
Terminal loop resistance: 1300 ohms maximum