Avaya Bogen PCMAAD User Manual

STEP 1 - If there are Zone Paging Modules to add to the PCMADD, please do so before you mount it.
STEP 2 - Mount the LUPCMADD approximately 4” below the existing LUPCMALL or any additional LUPCMADDs.
STEP 3 - Disconnect power from the entire PCM system.
STEP 4 - Follow the wiring diagram (see Figure 2) to connect the
CPU modules together.
STEP 5 - Use the chart on the right (Figure 1) to set the CPU
module switches.
STEP 6 - Verify connections and settings, then power up the system.
TE: Refer to the LUPCMALL manual for speaker connections and
operation of system.
Physical
Zones
10-18 19-27 28-36 37-45 46-54 55-63 64-72 73-81 82-90 91-99

Installation

1 2 3 4 5 6 7 8 9
10
Before You Start...
Paging Control System Expansion Assembly Model PCMADD
PEC CODE: 5323-107 COM CODE: 408186021 MODEL: LUPCMADD
Issue 1, October 1999 Specifications subject to change without notice. © 1999 Bogen Communications Inc. All rights reserved. Part No. 54-2010-01 Printed in Korea 9910 Select Code: 701-000-110

Description

The LUPCMADD Paging Control System Expansion Assembly can only be used with a LUPCMALL Paging Control System or another LUPCMADD to add more paging zones to your paging system.The LUPCMADD will add three additional paging zones to your system when the LUPCMALL or LUPCMADD already includes three zone paging modules.
Verify that there is a standard electrical outlet available for the power supply (not controlled by a wall switch).
Verify that there is at least 12” of open wall or rack space below the existing LUPCMALL or LUPCMADD.
LUPCMADD
Module
* All of the switches are off left.
Page 1 of 2
1 2 2, 1 3 3, 1 3, 2 3, 2, 1 4 4, 1 4, 2
Switch
Set to On
Your carton contains: * LUPCMADD Paging Control System Assembly * Pair of Rack Brackets * Power Supply * Installation Manual * Male-to-Male RCA Cable * Male-to-Female “Y” Adapter * Mounting Screws

Package Contents

Figure 1: CPU Module Switches
X1 X2 X3 X4
Figure 2: Wire Connections
Page 2 of 2
RCA JACK
USE PROVIDED “Y”
ADAPTER FOR MULTIPLE
LUPCMADDs
Wiring Connections
FROM
PCMALL
TO
PCMADD
X1 X2 X3 X4

IMPORTANT

-If using Hi-Power background music, also connect HPBGM (IN & RT) terminals of the units together.
-If using Lo-Power background music, also connect LPBGM (IN & RT) terminals of the units together.
PCM
TIM
PCM
CPU
X1 X2 IN RT
X3 X4 IN
RT
EM/SC GND AUX GND
LPBGM
HPBGM
+ 12 VDC
- 1.5A
PCM
TBM
PCM
ZPM
PCM
ZPM
PCM
ZPM
PCM
CPU
X1 X2 IN RT X3 X4 IN RT EM/SC GND AUX GND
+ 12 VDC
- 1.5A
LPBGM
HPBGM
PCM
ZPM