STEP 1 - If there are Zone Paging Modules to add to the PCMADD, please do so before you mount it.
STEP 2 - Mount the LUPCMADD approximately 4” below the existing LUPCMALL or any additional LUPCMADDs.
STEP 3 - Disconnect power from the entire PCM system.
STEP 4 - Follow the wiring diagram (see Figure 2) to connect the
CPU modules together.
STEP 5 - Use the chart on the right (Figure 1) to set the CPU
module switches.
STEP 6 - Verify connections and settings, then power up the system.
NO
TE: Refer to the LUPCMALL manual for speaker connections and
operation of system.
Physical
Zones
10-18
19-27
28-36
37-45
46-54
55-63
64-72
73-81
82-90
91-99
Installation
1
2
3
4
5
6
7
8
9
10
Before You Start...
Paging Control System Expansion
Assembly Model PCMADD
PEC CODE: 5323-107
COM CODE: 408186021
MODEL: LUPCMADD
Issue 1, October 1999
Specifications subject to change without notice.
© 1999 Bogen Communications Inc. All rights reserved.
Part No. 54-2010-01 Printed in Korea 9910
Select Code: 701-000-110
Description
The LUPCMADD Paging Control System Expansion Assembly can only be used with a LUPCMALL Paging Control System or
another LUPCMADD to add more paging zones to your paging system.The LUPCMADD will add three additional paging zones
to your system when the LUPCMALL or LUPCMADD already includes three zone paging modules.
Verify that there is a standard electrical outlet available for the power supply (not controlled by a wall switch).
Verify that there is at least 12” of open wall or rack space below the existing LUPCMALL or LUPCMADD.
LUPCMADD
Module
* All of the switches are off left.
Page 1 of 2
1
2
2, 1
3
3, 1
3, 2
3, 2, 1
4
4, 1
4, 2
Switch
Set to On
Your carton contains:
* LUPCMADD Paging Control System Assembly
* Pair of Rack Brackets
* Power Supply
* Installation Manual
* Male-to-Male RCA Cable
* Male-to-Female “Y” Adapter
* Mounting Screws
Package Contents
Figure 1: CPU Module Switches