Avaya Bogen Multi-Tone Generator Installation and Use Manual

Multi-Tone Generator
Installation and Use Manual
© 1999 Bogen Communications, Inc. All rights reserved. 54-2020-01 9910
Model: LUMUTGEN PEC Code: 5335-500
COM Code: 408184240 Select Code: 701-000-104
© 1999 Bogen Communications, Inc.
All Rights Reserved. Printed in U.S.A.
Notice
Every effort was made to ensure that the information in this guide was complete and accurate at the time of print­ing. However, information is subject to change.
Important Safety Information
Always follow these basic safety precautions when installing and using the unit.
1. Read and understand all instructions.
2. Follow all warnings and instructions marked on the prod­uct.
3. DO NOT block or cover the ventilation slots and open­ings.They prevent the product from overheating. DO NOT place the product in a separate enclosure or cabinet, unless proper ventilation is provided.
4. Never spill liquid on the product or drop objects into the ventilation slots and openings. Doing so may result in seri­ous damage to the components.
5. Repair or service must be performed by a factory authorized repair facility.
6.The product is provided with a UL-CSA approved, 3-wire ground type plug.This is a safety feature. DO NOT defeat the safety purpose of the grounding type plug. DO NOT staple or otherwise attach the AC power supply cord to building surfaces.
7. DO NOT use the product near water or in a wet or damp place (such as a wet basement).
8. DO NOT use extension cords.The product must be installed within 6 feet of a grounded outlet receptacle.
9. DO NOT install telephone wiring during a lightning storm.
10. DO NOT install telephone jacks in a wet location
unless the jack is specifically designed for wet locations.
11. Never touch uninsulated wires or terminals, unless the
line has been disconnected at the paging or controller interface.
12. Use caution when installing or modifying paging or con-
trol lines.
Support Information
Paging systems integrated with small phone systems such as Merlin Legend and Partner are supported by the National Service Assistance Center (NSAC).The main number for the NSAC is 800-628-2888. Paging systems integrated with large switches such as the DEFINITY G3 are supported by the Technical Service Center (TSC).The main number for
the TSC is 800-242-2121.
Page 2 of 4

Installation

CAUTION: To reduce the risk of fire or electric shock, do not expose this unit to rain or excessive moisture.
Mounting - The Multi-Tone Generator is designed for wall mount applications. To wall mount this unit, use the four
5/8” pan head screws with nylon washers (screws and washers not provided). Place the unit flush with the wall and screw it in place.
Wiring - The Multi-Tone Generator can be installed in a variety of configurations, dependent upon specific application
criteria. Figure 1 (on page 4) illustrates a common method of generating a tone signal over program (i.e., tape player,
tuner) input.When the contacts of an external switching device are closed, program input is interrupted by a burst of one of the tone signals. For longer signal duration, connect the CONTINUOUS and TRIGGER terminals (dotted line). The tone signal will be continuously generated until the external switch contacts (ALARM CLOSURE) are reopened.
Power Supply - The Multi-Tone Generator requires a power source of between 12 and 48V DC, either positive or
negative ground.
1. Connect the grounding lead from the chassis to the positive (+) terminal if a positive grounding system is used. Be
certain that the Multi-Tone Generator chassis does not come into contact with any other equipment with a negative ground.
2. If a negative-ground system is used, connect the grounding lead to the negative (-) terminal.
The Multi-Tone Generator is capable of generating four distinct signals: pulsed tone, slow whoop, repeating chime, and steady tone. Each of these four signals may be applied continuously or limited to a double burst (single burst only of the steady tone) for alarm signalling or pre-announcement. Signals are triggered by an external device that provides a contact closure. Both tone level and pitch are adjustable.
The Multi-Tone Generator will accept a high-level (max. 1.5V RMS) input from a program source, such as a tuner or
tape deck.Tone signal precedence over program input is built-in.

Description

Your carton contains: * Multi-Tone Generator Unit * Power Supply * Male RCA to Wires Connector * Female RCA to Wires Connector * Installation and Use Manual

Package Contents

Multi-Tone Generator
Page 3 of 4
-CHIME
-CONTINUOUS
-PULSED TONE
-SLO WHOOP
TONE LEVEL
-RESET
-STEADY TONE
PITCH
-TRIGGER
+ 12-48 -
VDC
AUDIO INREM STATUS
TBA
SIG OUTCOM

Operation

Tone Level - Tone level can be regulated by the front-panel screwdriver-adjustable TONE LEVEL control.Clockwise
rotation increases the level of the tone signal.
Pitch Control - A recessed, screwdriver-adjustable, PITCH control is located on the side-panel and is used to adjust the frequency of the tone signal.The signal can be varied to suit the individual application requirement.
Figure 2 shows how the Multi-Tone Generator may be used for emergency alarm signalling in an unattended system. Program input is interrupted by a continuous alarm tone when an external sensing and switching device (i.e., a bi-metal sensor) momentarily closes the contact at the TRIGGER terminal (“START”).A second external momentary switch con­nected to the RESET terminal (“STOP”) restores the circuit when the switch is momentarily closed.
+
Figure 1 - Tone Signalling Over a Program Source
Figure 2 - Generating a Continuous Emergency Alarm
Page 4 of 4
+
-
-
12-48
VDC
REM STATUS
AUDIO IN
COM
SIG OUT
TBA
AMPLIFIER
AUX
TO POWER
TUNER
SUPPLY
CONT
CHIME
SLO WHOOP
PULSED TONE
STEADY TONE
RESET
TRIGGER
C 74-6220-01
FOR LONGER SIGNAL DURATION, CONNECT CONTINUOUS AND TRIGGER TERMINALS (DOTTED LINE). SIGNAL WILL GENERATE TILL EXTERNAL CONTACTS REOPEN.
AS REQUIRED
CONNECT ONE
TO CONTACT
CLOSURE
CONT
CHIME
SLO WHOOP
PULSED TONE
STEADY TONE
RESET
TRIGGER
CONNECT
AS REQUIRED
STOP
START
AMPLIFIER
AUX
TO POWER
TUNER
C 74-2723-01
SUPPLY
+
+
-
-
12-48
VDC
REM STATUS
AUDIO IN
COM
SIG OUT
TBA
Loading...