STEP ATTENUATION
10 0dB
9 -3dB 8 -6dB 7 -9dB 6-12dB 5-15dB 4-18dB 3-21dB 2 -27dB 1 -33dB 0 Speaker Off
Red
Black
Green
This 10-step plus “off ” speaker attenuator allows the volume of a network of 70-volt speakers to be controlled from a remote loca­tion.The attenuator can handle speaker loads of up to 35W (max.) and fits into a double gang electrical box. Volume reduction takes place in 3dB increments except for the 2 lowest settings,which provide 6dB reduction increments.A speaker “off ” position is also provided.

Speaker Installation

Attenuator Wiring

70-volt Hot
lead
70-volt COM
Cable Shields
Cable to speakers
Speaker “+”
positive lead
Cable from amp or zone output
Wire Nuts (4)
Note: Cable shield is not connected to the speaker ­the shield simply “floats.”
Speaker “-”
(negative) lead
35W Attenuator
(for 70-volt speakers)
Speaker Load Maximum
35 Watts
Note: Use 22AWG shielded, twisted pair on all wire runs.
COM CODE: 401882956
PEC CODE: 2734-SPK

Attenuator Settings

PEC Code: 5335-005 COM Code: 408187169 Model: LU35W70VAT
35-W att Attenuator For 70V Speaker Line
Figure 1
Page 1 of 2
Issue 1,October 1999 54-2005-01 Printed in Korea 9910 © 1999 Bogen Communications Inc. All rights reserved. Specifications subject to change without notice. Select Code:701-000-102
_
+

Attenuator Installation

1) Cut a rectangular hole 4-1/16” wide and 3-3/4” high in the sheetrock where the attenuator is to be mounted.
2) Pull approximately 12” of the amplifier and speaker cables through the hole.
3) Push each of the separate cables through the elec­trical box entry holes and pull about 6” of cable out of the front of the box (see Figure 2).
4) Rotate the two screw-mounted tabs down against the box and slide the electrical box into the open­ing until it stops against the wall.
5) Begin to tighten both of the electrical box screws until the box is held firmly into the wall.The clips on the screws will rotate into place and clamp the box against the wall.
6) Make all the necessary electrical connections as shown in the “Attenuator Wiring” section on the front of this sheet (see Figure 1).
7) Remove the protective plastic film covering from the attenuator face plate.
8) Mount the attenuator to the electrical box using the 4 screws provided. Using a Phillips head screwdriver,screw the attenuator into place (see Figure 3).
4 1/16"4 1/16"
3 3/4"3 3/4"
Figure 2
Figure 3
Screw-mounted tab
(down)
Rotated screw-
mounted tab
Entry holes