LSI SAS 9300-16e PCI Express to 12Gb/s SAS Host Bus Adapter User Guide
May 2013
Revision History
Version and DateDescription of Changes
Version 2.0, May 2013Updated Section 5.5, Electrical Characteristics.
Version 1.0, March 2013Initial release of this document.
LSI, the LSI & Design logo, Storage.Networking.Accelerated., and Fusion-MPT are trademarks or registered trademarks of LSI Corporation in the United States and/or other countries. All other brand and
product names may be trademarks of their respective companies.
PCI Express and PCIe are registered trademarks of PCI-SIG.
LSI Corporation reserves the right to make changes to the product(s) or information disclosed herein at any time without notice. LSI Corporation does not assume any responsibility or liability arising out of
the application or use of any prod uct or ser vice de scribed her ein, except a s expressly a greed to in writin g by LSI Corporat ion; no r does th e purchase , lease, or use of a product or servic e from LS I Corpora tion
convey a license under any patent right s, cop yri ght s, tr adem ark righ ts, or any other of the intellectual property right s of LSI Corporation or of third pa rties. LS I pro duct s are not intended for use in life-support
appliances, devices, or systems. Use of any LSI product in such applications without written consent of the appropriate LSI officer is prohibited.
Corporate HeadquartersEmailWebsite
San Jose, CAglobalsupport@lsi.comwww.lsi.com
800-372-2447
LSI SAS 9300-16e PCI Express to 12Gb/s SAS Host Bus Adapter User Guide
May 2013
PCI Express Interface
Overview
LSI® SAS 9300-16e PCI Express® to 12Gb/s Serial Attached SCSI (SAS)
Host Bus Adapter User Guide
1Overview
The LSI® PCI Express® (PCIe®)-to-Serial Attached SCSI (SAS) host bus adapter (HBA), referred to as the LSI 12Gb/s SAS
HBA, provides high-performance external storage connectivity for servers and workstations. The LSI 12Gb/s SAS HBA
provides sixteen lanes of 12Gb/s SAS connectivity and is matched with eight lanes of PCIe 3.0 8Gb/s performance. The
LSI 12Gb/s SAS HBA is based on the Fusion-MPT™-architected LSI SAS 3008 controller that integrates the latest
enhancements in PCIe 3.0 technology and 12Gb/s SAS technology.
The LSI 12Gb/s SAS HBA has onboard Flash memory for the firmware.
2Features
This section lists the LSI 12Gb/s SAS HBA features.
Implements two LSI SAS 3008 eight-port 12Gb/s SAS to PCIe 3.0 controllers
Supports eight-lane, full-duplex PCIe 3.0 performance
Supports sixteen external 12Gb/s SATA+SAS ports
Supports SATA link rates of 3Gb/s and 6Gb/s
Supports SAS link rates of 3Gb/s, 6Gb/s, and 12Gb/s
Provides four x4 external mini-SAS HD connectors (SFF-8644)
Supports passive copper cable, active copper cable, and optical cable
Supports up to 1024 SATA or SAS end devices
Offered with a full-height bracket
Provides two heartbeat LEDs
3Functional Descriptions
3.1PCI Express Interface
The LSI SAS 9300-16e HBA uses two LSI SAS 3008 controller chips and one PCI Express switch to provide
high-bandwidth interconnection ability. PCIe is a high-speed standard local bus for point-to-point interfacing of I/O
components to the processor and the memory subsystems in high-end computers and servers.
The LSI 12Gb/s SAS HBA supports eight-lane PCIe performance up to 64Gb/s single direction and 128Gb/s
dual direction.
3.2SAS-3 Interface
The LSI SAS 3008 controller chip contains the SATA+SAS functionality for the LSI 12Gb/s SAS HBA. The following table
shows the LSI SAS 12Gb/s SAS performance.
LSI Corporation
- 4 -
Page 5
LSI SAS 9300-16e PCI Express to 12Gb/s SAS Host Bus Adapter User Guide
May 2013
Half DuplexFull Duplex
Narrow port (one lane), 1200 MB/s Narrow port (one lane), 2400 MB/s
Wide port (four lanes), 4800 MB/sWide port (four lanes), 9600 MB/s
4Operating System Support
Operating System Support
Memory
The LSI 12Gb/s SAS HBA supports all major operating systems: Windows®, Linux® Red Hat®, Linux SuSE® Enterprise
Server (SLES), Solaris
®
, and VMware®. Refer to http://www.lsi.com/support/products/Pages/default.aspx for details on
the software versions and device driver support. For Solaris support, contact the LSI Technical Support team.
NOTEThe LSI 12Gb/s SAS HBA supports the Solaris 10 operating system, and
®
Oracle
provides a built-in driver; installation of an LSI driver is not
required. For more information on the Oracle Solaris 10 driver and
installation, sign in at the following Oracle link.
https://support.oracle.com/
Contact Oracle support for Oracle driver or software support.
5LSI SAS 9300-16e HBA Characteristics
5.1Memory
The LSI 12Gb/s SAS HBA provides two 4-M × 16-bit Flash ROMs to store the firmware and the BIOS.
5.2LED
The LSI 12Gb/s SAS HBA Heartbeat LEDs, CR3 and CR4, blink green to indicate the HBA is capable of general activity.
5.3Connectors
PCIe Connector (EC1). The LSI 12Gb/s SAS HBA supports a x8 interface. The PCIe host interface connection is through
the edge connector, EC1, which provides connections on both the top (EC1 B) and bottom (EC1 A) of the board. The
signal definitions and pin numbers conform to the PCIe specification.
SATA+SAS Connectors (J6, J7). The LSI 12Gb/s SAS HBA supports SATA and SAS connectors through connectors that
are SFF-8644 mini-SAS HD, external connectors.
Auxiliary Power Connector (J5). The LSI 12Gb/s SAS HBA provides a 6-pin PCIe power connector.
5.4Physical Characteristics
The LSI 12Gb/s SAS HBA is a 6.6-in. × 4.4-in board. The component height on the top and bottom of the LSI 12Gb/s
SAS HBA is in accordance with the PCIe specification. The following figure shows the HBA board layout.
LSI Corporation
- 5 -
Page 6
LSI SAS 9300-16e PCI Express to 12Gb/s SAS Host Bus Adapter User Guide
The maximum power requirements for the LSI SAS 9300-16e HBA under normal operation are as follows:
PCIe 12.0 V = 2.35 A
PCIe 3.3 V = 0.13 A
Passive cable, nominal = 28.6 W
5.6Thermal and Atmospheric Limits
The atmospheric limits for the LSI 12Gb/s SAS HBA are as follows:
Temperature range: 0 °C to 55 °C (32 °F to 131 °F) (dry bulb)
Relative humidity range: 5% to 90% noncondensing
Maximum dew point temperature: 32 °C (89.6 °F)
Minimum airflow for the LSI SAS 9300-16e HBA:
— 220 LFPM at 35 °C inlet temperature
— 270 LFPM at 45 °C inlet temperature
— 350 LFPM at 55 °C inlet temperature
The following limits define the storage and transit environment for the LSI 12Gb/s SAS HBA:
Temperature range: –45 °C to +105 °C (–49 °F to +221 °F) (dry bulb)
Relative humidity range: 5% to 90% noncondensing
LSI Corporation
- 6 -
Page 7
LSI SAS 9300-16e PCI Express to 12Gb/s SAS Host Bus Adapter User Guide
May 2013
LSI 12Gb/s SAS HBA Certifications and Safety Characteristics
6LSI 12Gb/s SAS HBA Certifications and Safety Characteristics
All LSI 12Gb/s SAS HBAs meet or exceed the requirements of UL flammability rating 94V-0. Each bare board is marked
with the supplier’s name or trademark, type, and UL flammability rating. Because these boards are installed in a PCIe
bus slot, all voltages are less than the SELV 42.4-V limit.
The design and implementation of the LSI 12Gb/s SAS HBA minimizes electromagnetic emissions, susceptibility to
radio frequency energy, and the effects of electrostatic discharge.
The LSI 12Gb/s SAS HBA meets the following integrated electromagnetic interference (EMI) compliance labels:
CE mark
CISPR Class B
C-Tick mark
Canadian Compliance Statement
FCC Class B, marked with the FCC Self-Certification logo
Japan VCCI
Korean KCC
Tai wan BSMI
The LSI 12Gb/s SAS HBA meets the following environmental directives:
Thermal and Atmospheric Limits
RoHS
WEEE
7Hardware Detailed Installation Instructions
To install the LSI 12Gb/s SAS HBA, follow these steps:
1.Unpack the HBA, and inspect it for damage. Unpack the HBA in a static-free environment. Remove the HBA
from the antistatic bag, and carefully inspect the device for damage. If you notice any damage, contact LSI or your
reseller support representative.
AT TE N TI O NTo avoid the risk of data loss, make a backup of your data before
changing your system configuration.
2.Prepare the computer. Turn off the computer, and disconnect the power cord from the rear of the power supply.
CAUTIONDisconnect the computer from the power supply and from any
networks to which you will install the HBA, or you risk damaging the
system or experiencing electrical shock.
3.Remove the cover from the chassis.
4.Check the mounting bracket on the HBA (system-dependent). If required for your system, replace the
full-height mounting bracket that ships on the HBA with the low-profile bracket supplied.
5.Insert the HBA into an available PCIe slot. Locate an empty x8 PCIe slot. Remove the blank bracket panel on the
rear of the computer that aligns with the empty PCIe slot. Save this bracket screw, if applicable. Align the HBA to a
PCIe slot. Press down gently, but firmly, to seat the HBA correctly in the slot. The following figure shows how to
insert the HBA into a PCIe slot.
NOTEThe shape, size, and locations of the components on your HBA and its
bracket might vary from this illustration. The HBA requires a x8
PCIe slot.
LSI Corporation
- 7 -
Page 8
LSI SAS 9300-16e PCI Express to 12Gb/s SAS Host Bus Adapter User Guide
?
%DGEOF(OST"OARD
0#)%XPRESSX3LOT
"RACKET
3CREW
0RESS
(ERE
0RESS
(ERE
4O$RIVE
%NCLOSURES
-INI3!3($
%XTERNAL
#ONNECTORS
May 2013
Figure 2 Install an LSI 12Gb/s x8 HBA in a PCIe Slot
Thermal and Atmospheric Limits
Technical Support
6.Secure the HBA bracket to the system’s chassis. Install the bracket screw, if applicable, or engage the system
retention mechanism to secure the HBA to the system’s chassis.
7.Replace the cover of the chassis.
8.Connect SAS cables between the HBA and the SAS enclosure that contains SATA or SAS devices. The LSI
12Gb/s SAS HBA has four SFF-8644, external x4 mini-SAS HD connectors. Use a cable with an external mini-SAS
HD connector (SFF-8644) on one end (to connect to the HBA) and the appropriate connector to attach to the
enclosure that contains SAS or SATA devices on the other end.
9.Replace the cover and any power cords, and power up the system. Replace the chassis’s cover, reconnect any
power cords, and reconnect any network cables. Turn on the power.
The hardware installation of your LSI 12Gb/s SAS HBA is complete.
8Technical Support
For assistance installing, configuring, or running the LSI 12Gb/s SAS HBA, contact LSI Technical Support:
E-mail:support@lsi.com
Phone: 1-800-633-4545 (North America)
00-800-5745-6442 (International)
Website: www.lsi.com/support
LSI Corporation
- 8 -
Page 9
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.