Thank you for purchasing an Autonics product.
This user manual contains information about the product and its proper use,
and should be kept in a place where it will be easy to access.
Please familiarize yourself with the information in this manual before using the product.
This manual provides detailed information on the product's features. It does not offer any
guarantee concerning matters beyond the scope of this manual.
This manual may not be edited or reproduced in either part or whole without permission.
This programming manual is not provided as part of the product package. Please visit our
home-page (www.autonics.com) to download a copy.
The manual's content may vary depending on changes to the product's software and other
unforeseen developments within Autonics, and is subject to change without prior notice.
Upgrade notice is provided through our homepage.
We contrived to describe this manual more easily and correctly. However, if there are any
corrections or questions, please notify us these on our homepage.
Following these safety considerations will ensure the safe and proper use of the product
and help prevent accidents, as well as minimizing possible hazards.
Safety considerations are categorized as Warnings and Cautions, as defined below:
Warning
Caution
Failure to follow the instructions may lead to a serious injury
or accident.
Failure to follow the instructions may lead to a minor injury
or accident.
Fail-safe device must be installed when using the unit with machinery that may cause
serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment,
ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster
prevention devices, etc.)
Failure to follow this instruction may result in personal injury, fire, or economic loss.
Do not use this product for protecting human body or part of body.
Do not see light LED directly or direct beam at person.
Failure to follow this instruction may result in damage on eyes.
Do not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in fire.
Check connections and connect cables.
Failure to follow this instruction may result in fire.
Do not disassemble or modify the unit.
Failure to follow this instruction may result in fire.
Use the unit within the rated specifications.
Failure to follow this instruction may result in fire or product damage.
Use dry cloth to clean the unit. Do not use water or organic solvent when cleaning the unit.
Failure to follow this instruction may result in fire.
Do not use the unit where flammable/explosive/corrosive gas, humidity, direct sunlight,
radiant heat, vibration, impact or salt may be present.
Failure to follow this instruction may result in fire or explosion.
Keep metal chip, dust and wire residue from flowing into the unit.
Failure to follow this instruction may result in fire or product damage.
The above specifications are subject to change and some models may be discontinued
without notice.
Be sure to follow cautions written in the instruction manual, user manual and the
technical descriptions (catalog, homepage).
Follow instructions in Cautions during Use. Otherwise, it may cause unexpected accidents.
24VDC power supply should be insulated and limited voltage/current or Class 2, SELV
power supply device.
In order to avoid malfunction from static electricity or noise, ground shield wire of the power
I/O cable.
Do not disconnect the power supply while setting operation or saving set information.
It may cause data loss.
Do not disconnect the power supply while updating firmware.
It may cause product damage.
Keep optical section of the sensor away from the contact with water, dust and oil.
It may cause malfunction.
When changing the light or filter, use the assembly tool and observe installation instruction.
When the sensor is not used for a long time, separate the power cable to store.
When connecting network, connection must be operated by technical expert.
In the following case, disconnect the power supply immediately. It may cause fire or product
damage.
① When water or foreign substance is detected in the product
② When the product is dropped or case is damaged
③ When smoke or smell is detected from the product
Do not use the product in the place where strong magnetic field or electric noise is
generated.
This unit may be used in the following environments.
① Indoor (in the environment conditions in specifications)
VG series, vision sensor, is the light and sensor integrated type which has 13 types of inspection
functions, so that it can be applied and utilized for various environment and condition. Before
applying to actual environment to utilize, using simulator can realize inspection.
Since it is available to set 32 work groups and 64 inspection items for each work group, vision
sensor can flexibly response to the change of work environment.
Furthermore, parameter setting and monitoring from PC is simple through Ethernet
communication.
Light integrated vision sensor
Minimized image distortion with global shutter method
Proprietary technology to block optical interference to improve optical performance (patent)
Stronger in environment of vibration or impact with lens cover detachment prevention
length, angle, diameter, object counting, color identification, area of color, object of color
counting
Flexible response to changing work environment by setting 32 work groups (64 inspection
items for each work group)
Easy work group managing and parameter setting
: Through vision sensor program (Vision Master), it is available to copy or save work group
saved in vision sensor to PC or work group saved in PC to vision sensor.
Real-time monitoring of inspection result
: Through vision sensor program (Vision Master), it is available to monitor the Pass/Fail
inspection result of inspection items in real-time. Furthermore, statistics data of the
inspection result can be generated, and it can be also initialized during inspection.
Realization of inspection by simulator
: Through vision sensor program (Vision Master), it is available to register work group with
an image saved in PC to test inspection, without vision sensor.
Saving data to FTP server
: According to the settings, an inspection result image can be transmitted and saved in FTP
server. Furthermore, setting the file naming rule can help to manage file.
Applicable to various environment with various light and filter
- 4 types of light (white/red/green/blue)
- 4 types of color filter (red/green/blue/infrared blocking)
Visit our homepage (www.autonics.com) to download vision sensor program (Vision Master).
Before using the product, please check whether all accessories above are included.
If there is a damaged or missing accessory, please contact Autonics sales team or retailer.
Please refer to the model name below, when purchasing the lost accessory.
2nd Place the sensing target at the center of the vision sensor lens.
5 Installation
5.3Focus Adjustment
After installing and running Vision Master, use the focusing guide function to adjust the focus.
Using (-) screwdriver, turn focus adjuster to right and left to adjust the focus.
※Please refer to '6.3 Installation of Vision Master' for the installation of Vision Master and
network setting.
※Please refer to '6.6.2 Camera (6) Focusing guide ' for the focusing guide.
1st Put and fix the assembly tool into the groove on the side of the vision sensor.
2nd While fixing the vision sensor with the assembly tool, hold the lens cover and disassemble it
in a counter clock wise direction.
3rd Disassemble the light cover using the (+) screwdriver, and disassemble the inner LED light.
5 Installation
4th Place the connection pin of PCB of the inner LED light to face the direction of 6 o’clock and
Compares features of the registered image and input image to search for a similar
pattern position, and inspects the input image with information of the searched pattern
position and rotation angle.
Alignment
Brightness
Contrast
<Template>
<Pass>
<Fail>
Inspects brightness of the ROI in the input image based on the mean brightness value of
the ROI (Region of Interest) in the registered image.
<Template>
<Pass>
<Fail>
Inspects contrast of the ROI in the input image based on contrast of the ROI in the
registered image.
<Template>
<Pass>
<Fail>
Area
.
Edge
Inspects the ROI area of the input image based on the ROI area of the image registered
by user.
<Template>
<Pass>
<Fail>
Inspects the direction of the edge in the input image based on the edge registered by
user in the same area.
You can check whole part of license agreement article by rolling mouse scroll downward,
clicking downward arrow or press “Page Down(PgDn)” Key of the keyboard.
Please read the articles thoroughly before click [I Agree] button.
6th Choose Install Location window appears.
Default installation path is as follows.
C:\Program Files (x86)\Autonics\Vision Master\
Click [OK] button to install the program in the default installation path.
7th Click [Install] button to install the program in the default installation path.
If you want to install the program in another installation path, click [Browse..] button to
designate a folder you want to install in and click [OK] button.
8th Installation progress is displayed in the status window as follows.
9th Installation Complete window appears after installation is completed.
If the check box in the Installation Complete window is checked, Vision Master runs upon
completion of installation.
You can run Vision Master by double-clicking the Vision Master icon on the desktop.
This section explains the folder structure created when you installed Vision Master.
The Vision Master folder is created in [C:\Program Files (x86)\Autonics\] as a subfolder unless
you select a new destination to change location of Vision Master folder.
After Vision Master is installed completely, Vision Master installation folder and related folders
are created as follows in [C:\Users\(Account name)\Documents\Autonics\] as subfolders and
work groups and documents are saved in. The program and all relevant documents are stored in
these folders.
6 Vision Sensor Program [Vision Master]
(1)Image folder
If Save Result Image inspection parameter of Vision Master is set to ON, inspection result
images are saved in the designated location. Saving location is fixed, so that is cannot be
changed by user.
Inspection result images are saved in [C:\Users\(Account name)\Documents\Autonics\Vision
Master\Image\ResultImage].
(2)Sample folder
This folder contains work groups for samples. Load sample files from this folder to Vision
Master to test inspection.
(3)Work folder
When saving work groups from Vision Master to PC, the work groups are saved in this folder.
When copying work groups from a device to PC using work group manager, the work
groups are saved in this folder.
If the saving location is changed when saving work groups in PC, work groups are saved in
the changed folder.
(4)Log folder
Log files of connection/disconnection with a device or inspection result are saved.
6.3.4Removal of the program
There are procedures to uninstall Vision Master, Start > Program > Vision Master > Uninstall or
Start > Setting > Control Panel > Add/Remove a Program > Vision Master.
When a confirmation window appears after selecting Remove, click [Ye s] button to remove
Vision Master from the computer.
Change the network settings in Vision Master to connect with a device (vision sensor).
When executing Vision Master, Select Device window appears. Simulator or connected devices
are displayed in the window. You can check connectable devices and connected devices using
Refresh icon () on the top of the window.
Factory default of the device (vision sensor) is as follows.
You can change IP address of the device to connect.
1st Select the device to connect, and click “After IP change, connect” button.
2nd Change IP address in Change Network Setting window.
If changed IP address is same with another IP address which is used in another PC of device,
network error can occurs due to IP address conflicts.
(2)Manual search of IP address
If a device is not recognized while it is connected, click “Manual IP Address Searching” and
search IP address of the device to connect.
(This is usable only when Gateway of the device and PC are same.)
The program screen is divided into sections as shown in the preceding screenshot and each
section is composed of the following items.
2 Tool bar
Setting
3
menu
Image
4
window
Inspection
5
result
Displays icons of frequently used menu, settings of image window, camera
snap, or etc.
Displays vision sensor setting parameter menu.
If none of device of connected, it is available to connect simulator to
register work group and inspection test.
Activation of the setting menu depends on the type of the connected device
(simulator or device)
Displayed image is different according to the mode and settings.
- Setting mode: displays a taken image by vision sensor or selected image
between master image to register work group and loaded image to preview
window.
- Operation mode: displays taken images according to the “View Result
Image” settings. Please refer to '6.6.6 Inspection'.
Displays inspection result (Pass/Fail) of work group.
If the ‘Add Taken Image to Preview Window’ icon () is activated,
preview window displays images taken by the vision sensor, which are
different according to the mode and settings.
- Setting mode: displays all images taken by the vision sensor.
- Operation mode: while inspecting, displays taken images according to the
‘View Result Image’ settings. Please refer to '6.6.6 Inspection'.
Preview
6
window
Right click in the preview window to display setting menu as follows.
Displays status information of the device and work group.
- Device status
: displays information of simulator or device (vision sensor) connected to
Vision Master. It is available to connect or disconnect device. Indicator on
the top right side enables to check the communication status between
Vision Master and the device, when the device is connected. The indicator
flashes while data communication.
Status
7
information
- Work group status: displays status of currently registered work group.
8 Parameter Displays specific parameters in the setting menu.
9
Image
information
Displays brightness value and pixel coordinate of the point where the
mouse cursor is pointing on the image window.
Open Image: Opens the image to inspect.
Open All Images from Folder: Opens the folder of images to inspect.
Save Image: Saves the image displayed in Image window.
Work Group Manager: Displays a list of work group saved in the PC or device to copy,
delete, or save. It is available to set work group to use when the device turns on.
1
2
3
4
Deletes selected work group.
Selects a folder in the PC to load work group from.
Copies work group from the device to the PC.
Copies work group from the PC to the device.
5
Selects work group to operate when the device turns on.
New Work Group: Registers new work group.
Load Work Group from PC: Loads work group from the local disk of PC.
Work groups are saved in the default folder [C:\Users\ (Account name)
\Documents\Autonics\Vision Master\Work] or the folder designated by user.
Save Work Group to PC: Saves work groups registered and set in Vision Master to the
local disk of PC.
Work groups are saved in the default folder [C:\Users\ (Account name)
\Documents\Autonics\Vision Master\Work] or the folder designated by user.
Load Work Group from Device: Loads work group from the device (vision sensor).
Save Work Group to Device: Saves work groups registered and set in Vision Master to
the device (vision sensor). Click number of work group to save to set the name of work
group. At that moment, selected work group can be set as operating work group when
the device turns on. Work group can be registered and saved up to 32.
I/O Te s t: Displays input status with the indicators (no input: / input:). Also it is
available to set control output type (NPN/PNP) and whether use each output or not.
I/O test is only for testing output, so that it is not associated with settings of output
parameter
Firmware Update: Updates firmware version of the device (vision sensor).
Device reset: Resets the device, deleting saved work group and set parameters from
the device.
(3)Help
User Manual: Loads user manual.
Language: Changes program language.
Vision Master Update: Updates version of Vision Master.
Vision Master Information: Displays information about version of Vision Master and
It is available to set vision sensor and PC network.
Device: Displays currently connected vision sensor to Vision Master.
IP / MAC Address: Displays IP / MAC address of the connected device.
Setting: Changes IP address setting of the currently connected device.
[Current Network Setting] is network information of the currently connected device. To
change network setting, enter new information in [New Network Setting].
Image file naming rule is as flows.
Item can be set up to 5, and you can customize the order of the items.
Image Number: It is number of taken image. It is necessary for image file naming.
Image Name: User can set image name using only Korean, English alphabet, number, and
some of special characters (except “ < > ? * / \ |)
Inspection Result: Displays inspection result of Pass/Fail.
Work Group Number / Work Group Name: Displays number and name of inspecting
work group.
Image format filename extension: It is image format filename extension. It displays
Exposure time is the time span for which the vision sensor is exposed to the light.
The longer exposure time is, the brighter the taken image is, and the shorter exposure time
is, the darker the taken image is.
Setting range is from 20 to 10,000us.
(2)Exposure delay time
Exposure delay time delays the light receiving point of vision sensor.
Setting range is from 30 to 10,000us.
(3)Frame per second
Frame per second is Frame rate which is the number of images taken per 1 second.
It is settable only when the trigger mode is set to “internal trigger”.
Setting range is from 1 to 60fps.
※In the external trigger mode, the vision sensor takes images with external input signal, so
that you cannot set the frame per second.
※In the free-run trigger mode, the vision sensor takes images at the fastest speed which the
vision sensor can.
(The shorter exposure time is, the faster the vision sensor can take.)
(4)Gain
It is adjusting gain of CMOS image sensor.
As higher gain level makes image brighter, increased noises makes resolution low.
Setting range is from the level 1 to 16.
You can set whether to use inner LED light or not. (Use: /not use: )
Light is synchronized with trigger signal and exposure time.
Setting range is from the level 1 to 16.
(6)Focusing guide
Focusing guide makes adjusting image focus with the focus adjuster convenient.
After setting ROI of the sensing target and checking the focusing guide value, rotate the
focus adjuster to the point where the focusing guide value is the highest and fix it at the
point to use.
How to adjust focus with focusing guide.
1st Click focusing guide button.
Focusing guide ON() /OFF ()
2nd In the image window, the focusing guide value and area is displayed on the master image.
Adjust the area to focus on. The higher the focusing guide value is, the clearer focus on the
image is.
3rd Click continuous snap () on the toolbar on the top.
4th Checking consecutively taken images, rotate the focus adjuster to the FAR or NEAR
direction. Since initial setting is unknown, rotate the focus adjuster to both FAR and NEAR
directions and fix the adjuster at the point where the focusing guide value is the highest.
When sensing target is in near
→ rotate to the NEAR
direction.
Focus adjusting is finished. When sensing object is far
Calibration has two method of ‘actual measurement’ and ‘approximate measurement’. Since
those methods cannot be set at the same time, you have to select one method of them.
Claibration calulates ㎛ per 1 pixel to register.
Since the vision sensor measures distance in unit of pixel, use calibration function for calculating
in unit of ㎛.
(1)Actual measurement
Pixel Distance: It displays distance between edge A and edge B in pixel.
Edge Threshold A/B: It is for setting edge threshold to detect edge.
With the higher edge threshold value, edge of high contrast is detected, and with the
lower edge threshold value, edge of low contrast can be also detected.
Actual Distance: It is for entering actual distance between two edges in unit of ㎛.
After setting the edge threshold value and entering the actual distance, click ‘OK’
()
the right bottom corner to register values after calculating distance per 1 pixel into unit of ㎛
based on the set values in ‘Actual Measurement’ tab.
(2)Approximate measurement
Focal Length: It is for selecting effective focal length of the connected device (vision
sensor).
Working Distance: It is for entering distance between sensing target and the vision
sensor.
After selecting focal length and entering the working distance, click ‘OK’
()
in the right
bottom corner to register values after calculating distance per 1 pixel into unit of ㎛ based
on the working distance and FOV by effective focal length.
Trigger input (TRIG): The selected trigger mode which set in the camera menu is the
image taking signal.
Work group change (IN0 to IN3)
- Serial input (IN0, IN1): Input 0 and input 1 are set to work group change – Clock or
work group change – Data, and work group is changed according to the serial input.
- Parallel input (IN0 to IN3): From input 0 to input 3 are set to each of work group
change bit 0 to 3, and work group is changed according to the parallel input.
Encoder input (IN2, IN3): After input of trigger signal, the vision sensor takes image
after waiting for a while according to the number of encoder pulse. The types of
encoder input consist of Up counter/Down counter, and Quadrature. Encoder input is
used for the trigger delay mode. Maximum 100kHz input can be recognized.
(2)Active level
According to the active level, trigger is applied at High or Low. To avoid chattering of trigger
signal, the vision sensor starts taking an image when the signal is maintained for 1ms.
(1)Work group change – parallel input (IN0 to IN3)
According to the parallel input, work group is changed.
With parallel input, work group from 1 to 16 can be changed to.
(Following table is based on the High active level.)
According to the serial input, work group is changed.
Although data is 8-bit, 5 less significant bits are used, because the maximum number of
work group is 32.
With serial input, work group from 1 to 32 can be changed to.
Input
Bit 0 Bit 1 Bit 2 Bit 3 Bit 4 Bit 5 Bit 6 Bit 7
Work group
Work group 1 0 0 0 0 0 0 0 0
Work group 2 1 0 0 0 0 0 0 0
Work group 3 0 1 0 0 0 0 0 0
Work group 4 1 1 0 0 0 0 0 0
Work group 5 0 0 1 0 0 0 0 0
… … … … … … … … …
Work group 32 1 1 1 1 1 0 0 0
- Start bit: Start bit holds the data signal at Low (Falling edge) for 20ms.
- Clock bit: Clock bit is pulse of 20ms interval which acquires data at the Rising edge.
- Data bit: Data bit is synchronized with Falling edge of the clock signal and holds Low or
High for 20ms.
- End bit: After 8
When changing work group of the vision sensor to work group 6 with the serial input signal, input
the data signal as follows.
You can use encoder input when you want to use the trigger delay mode of external trigger
input on encoder pulse.
Camera trigger occurs after calculating moving distance according to the number of input
pulse.
Up counter/Down counter (IN2, IN3)
Input 2 and input 3 are used as each of encoder input up counter and down counter.
The number of pulse is counted up or down according to the active level. If you use only one
encoder input, connect unusing input terminal to COMMON. Rising edge is counted in the
high active level, and falling edge is counted in the low active level.
Quadrature A/Quadrature B (IN2, IN3)
Input 2 and input 3 are operated in encoder Quadrature. Both rising edge and falling edge of
two encoders are counted.
You can use the alarm cleared input to cleare alarm which is set in the output menu, when
alarm is ON. Although alarm is cleared, alarm occures again in the status at alarm condition
which is set in the output menu,
You can select pulse type for output.
You can select pulse type only when the output mode is set to ‘Inspection complete’,
‘Inspection result’, or ‘Alarm’.
Pulse: Output signal is output during set output duration.
Latch: Output signal is kept outputting before next output signal.
(4)Duration
Duration is the time period of maintaining inspection result output signal for.
You can set duration by setting output mode to “Inspection result” and pulse type to “Pulse”.
Setting range is from 1 to 60,000ms.
Timing diagram of output duration (ms).
(5)Delay type
Delay type is the moment of applying output delay time to. You can set whether to delay
output after inspection completed or to delay output after trigger input.
Delay time is the time period of delaying inspection result output for, after starting of output
delay operation.
Setting range when delay type is “After inspection completed”: 0 to 60,000ms
Setting range when delay type is “After trigger input”: 17 to 60,000ms
Edit: Select the registered work in the list and click Edit to edit the work.
Delete / Delete All: Select the registered work in the list and delete a work or delete all
works.
Change master image: You can change image template of the work to register. The currently
displayed image in the image window is registered as master image.
You can copy and paste registered works in the work list by using Ctrl+C and Ct rl +V.
It is except for Alignment 1 work.
1st Select a work to copy, and press Ctrl+C key to copy.
e.g.) Brightness 1
2nd Press Ctrl+V key to open the message pop-up as below, and click ‘OK’.
3rd The work is copied.
4th Select the copy of the work and click ‘Edit’ to change specific settings of the work.
When setting output with logic combination, set output condition using logical operator for each
output.
AND/OR: You can select logic operator.
Invert none: You can set logical option of all work to NONE(-).
Invert all: You can set logical option of all work to NOT.
Delete all/Delete logical operator: You can delete all registered settings of with Delete all
and registered logic operator with Delete logical operator.
Add logical operator: You can add logical operator (AND/OR).
Add work/Delete work: You can add registered work to logical output or delete work from
Work name: Displays work name of inspection items.
Result value: Displays measured result value of each work ROI.
Result: Displays pass/fail for inspection result.
Pass/Fail: Displays counting of the number of pass/fail and pass rate.
Operation time: Displays operation time of each inspection item.
Reset statistics: Resets all statistics about inspection result including pass () /
fail () status and operation time.
Input trigger: Displays statistics of input trigger. It helps you to check input is operating
in normal status by counting the number of pass/fail status of input trigger.
Work: Displays statistics of work. It displays the number of inspection result of All pass,
One or more failure, the number of total work, and inspection time.
When operating device inspection with calibration function, result value of the ‘edge’, ‘length’,
and ‘diameter’ inspections are displayed as actual value in the unit of mm, not pixel.
Inspection result value without calibration function
Inspection result value with calibration function
You can use the alignment function to align position and orientation of the target based on the
registered target.
Alignment compares features of the registered target and features of the input image to figure
out location of similar pattern, and then inspects the input image based on location and rotation
angle of the target. It is used to check the presence of inspection target to rotate, to inspect
pattern, or to align position of the target.
6 Vision Sensor Program [Vision Master]
1 Similarity It is the similarity between registered template and detected template.
Similarity
2
threshold
3 Edge threshold
4 Edge type
5 Edge contrast
Rotation angle
6
range (±°)
Automatic
7
teaching
8 ROI type
※1
It is discrimination value of the similarity for deciding pass/fail.
It is threshold to detect edge.
Only edges with high contrast can be detected in high edge threshold,
while edges with low contrast also can be detected in low edge
threshold.
It limits amount of information according to the edge direction.
- Curve: It leads pixels from all edges.
- Straight: It leads pixels only from straight edge.
It limits amount of edge information according to the contrast value.
- High: It uses edges of high contrast.
- Medium: It uses edges of high and medium contrast.
- Low: It uses edges of high, medium, and low contrast.
It limits detecting area to the set angle range, by setting angle range of
the rotated image to detect.
It operates teaching automatically, when user changes parameter or
adjust ROI.
When inspecting inspection items including alignment, alignment is prior to any other inspection
items, so that rotating inspection target by alignment also rotates position of other inspection
items.
If you want to apply alignment to each inspection, check ‘Apply alignment’ in the right bottom.
X: moving X axis coordinate / Y: moving Y axis coordinate / R: angle
Examples of pass/fail when inspecting multiple work including alignment
Registering template of the inspection target (registering alignment)
You can use the brightness function to inspect average brightness of the target.
Brightness compares mean brightness of the registered ROI and that of input image ROI. It sets
pass range based on the mean brightness value of the registered ROI. The mean brightness
value of the inspection target within the pass range is regarded as Pass, while the mean
brightness value of the inspection target out of the pass range is regarded as Fail.
6 Vision Sensor Program [Vision Master]
It sets the pass/fail range of brightness.
1 Pass range
2 Automatic teaching
3 ROI type
4 OK/Cancel It registers work to work group or cancel to register.
Lower limit ROI mean Upper limit
for pass brightness value for pass
Even if user set the pass range, it teaches pass range based on mean
brightness of ROI.
You can use contrast function to inspect average contrast of the target.
Contrast is amount of gap between bright part and dark part in the image.
Contrast compares registered ROI contrast and ROI contrast of the input image to figure out
changes in contrast. It sets pass range based on the registered contrast value of ROI. The
contrast value of the inspection target within the pass range is regarded as Pass, while the
contrast value of the inspection target out of the pass range is regarded as Fail. The contrast
value is displayed in the percentage.
6 Vision Sensor Program [Vision Master]
It sets the pass/fail range of contrast.
2 Pass range
Automatic
3
teaching
4 ROI type
5 OK/Cancel It registers work to work group or cancel to register.
Lower limit ROI Upper limit
for pass average contrast for pass
Even if user set the pass range, it teaches pass range based on the
average contrast value of ROI.
You can use the area function to inspect area of the target.
Area compares difference between registered ROI area and ROI area in the input image. It sets
the pass range based on the registered ROI area. The area of the inspection target within the
pass range is regarded as Pass, while the area of the inspection target without the pass range is
regarded as Fail.
6 Vision Sensor Program [Vision Master]
1 Pass range
2 Binary threshold
3 Extraction mode
It sets the pass/fail range of area.
Lower limit Measured ROI Upper limit
for pass area value for pass
It sets the threshold value to detect area.
It is to process inspection with the binary coded threshold value.
After converting each pixel of the image under the threshold value to 0
and each pixel of the image over the threshold value to 1, 0 passes the
area inspection, while 1 fails to pass the area inspection.
It sets method of detecting area.
Item
Descrip
tion
Dark object on the bright
background
Extracting darker area
compared to the brightness
standard
Bright object on the dark
background
Extracting brighter area
compared to the brightness
standard
You can use the edge function to inspect the presence of the edge.
Edge compares directions of the registered edge and edges in the same area of the input image
to detect the presence of the edge. It sets the pass range based on the direction of the
registered edge. The edge of the inspection target in the pass range is regarded as Pass, while
the edge of the inspection target out of the pass range is regarded as Fail.
6 Vision Sensor Program [Vision Master]
1
Edge angle(°)
2 Edge threshold
3
Pass range(±°)
4 Position threshold
It is the measured angle value of edge grade.
It sets threshold to detect edge.
Only edges with high contrast can be detected in high edge threshold,
while edges with low contrast also can be detected in low edge
threshold.
It sets the pass/fail range of edge.
Setting range: ±0 to ±10°
It is range of the distance between edge at ROI teaching and edge
detected from inspection target.
If the distance between edge at ROI teaching (0) and edge detected
from inspection target is within the range of position threshold, it is
processed as pass.
You can use the shape comparison function to inspect the shape of the object.
Shape comparison compares features and patterns of the terget object in the ROI of the input
image and that of the registered image.
It sets pass range based on the similarity of the ROI in the registered image and the ROI in the
input image.
Similarity of the two images over the threshold is regarded as Pass, while similarity of the two
images under the threshold is regarded as Fail.
1 Similarity It is similarity of the registered template and the detected template.
Similarity
2
threshold
3 Edge threshold
Automatic
4
teaching
5 ROI type
6 OK/Cancel It registers work to work group or cancel to register.
※1
It is similarity discrimination value for determining pass/fail.
It sets threshold to detect edge.
Only edges with high contrast can be detected in high edge threshold,
while edges with low contrast also can be detected in low edge
threshold.
Even if user set the pass range, it teaches pass range based on the
pixel of ROI.
You can use the length function to inspect the length between two edges. The length unit is pixel.
Base points of measuring length are two edges on each of two arrows. Length sets the pass
range based on the length between two registered edges. The measured length of the inspection
target within the pass range is regarded as Pass, while the measured length of the inspection
target out of the pass range is regarded as Fail.
It sets the pass/fail range of length.
1 Pass range
2 Edge threshold A/B
3 Automatic teaching
4 ROI type
5 OK/Cancel It registers work to work group or cancel to register.
Lower limit Measured ROI Upper limit
for pass length value for pass
It sets threshold to detect edge.
Only edges with high contrast can be detected in high edge
threshold, while edges with low contrast also can be detected in low
edge threshold.
Even if user set the pass range, it teaches pass range based on the
pixel of ROI.
It sets type of ROI to inspect.
In the ROI area, the program scans the edge in the arrow direction
and firstly detected edge becomes standard for inspection.
(two arrows)
※Threshold is the boundary value when a value is discontinuously changed.
You can use the angle function to inspect the angle between two edges. The unit of angle is º
(degree).
Angle measures angle of crossing point which is between two edges of registered arrows.
It sets the pass range based on the angle between two registered edges. The measured angle of
the inspection target within the pass range is regarded as Pass, while the measured angle of the
inspection target out of the pass range is regarded as Fail.
It sets the pass/fail range of angle.
1 Pass range
2 Edge threshold A/B
3 Automatic teaching
4 ROI type
5 OK/Cancel It registers work to work group or cancel to register.
Lower limit Measured ROI Upper limit
for pass angle value for pass
It sets threshold to detect edge.
Only edges with high contrast can be detected in high edge threshold,
while edges with low contrast also can be detected in low edge
threshold.
Even if user set the pass range, it teaches pass range based on the
pixel of ROI.
It sets type of ROI to inspect.
In the ROI area, the program scans the edge in the arrow direction
and firstly detected edge becomes standard for inspection.
(two arrows)
※Threshold is the boundary value when a value is discontinuously changed.