Autonics M4N Series Catalog Page

M4N Series
DIN W48×H24mm Small Size Digital Panel Meter
Features
● Max. display: 1999
● 7-segment LED display
● Power supply: 5VDC, 12-24VDC
Please read “Safety Considerations” in the instruction manual before using.
Ordering Information
00
M 4 N 0DV1
Item
1: 1-5VDC mearsurement input is option.
Specifications
00
Model M4N-DV-
Measurement input DC voltage DC current DC4-20mA
Power supply 5VDCᜡ, 12-24VDC
Allowable voltage range 90 to 110% of rated voltage
Power consumption 2W
Display method 7-segment LED display (red) (character height: 10mm)
Max. display range 1999
Display accuracy F.S. ±0.2% rdg ±1-digit
Sampling period 300ms
A/D switching method Dual integral method
Response ime Approx. 2 sec (0 to 1999)
Max. allowable input 150% of measurement input range
Sampling time 2.5 times/sec
Insulation resistance Over 100MΩ (at 500VDC megger)
Dielectric strength 2000VAC 50/60Hz for 1 min
Noise immunity ±100V the square wave noise (pulse width: 1㎲) by the noise simulator
Vibration
Shock
Environment
Unit weight Approx. 44g
Environment resistance is rated at no freezing or condensation.
- -
Measurement input
Power supply
Measurement function (input)
Size
Digit
□□
DC voltage input F.S. DC current input F.S.
1 199.9mV 199.9μA
2 1.999V 1.999mA
3 19.99V 19.99mA
4 199.9V 199.9mA
X Option Option
0 5VDC
1 12-24VDC
DV DC Voltage
DA DC Current
DI DC4-20mA (scaling meter)
-I
N DIN W48×H24mm
-
4 1999 (3½-digit)
-
M Meter
l J
M4N-DA- M4N-DI-
l
□□
1
J
J J
Mechanical 0.75mm amplitude at frequency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 1 hour
Malfunction 0.5mm amplitude at frquency of 10 to 55Hz (for 1 min) in each X, Y, Z direction for 10 min
Mechanical 300m/s² (approx. 30G) in each X, Y, Z direction for 3 times
Malfunction 100m/s² (approx. 10G) in each X, Y, Z direction for 3 times
Ambient temperature -10 to 50
Ambient humidity 35 to 85%RH, storage: 35 to 95%RH
℃, storage: -20 to 60℃
□□
O-46
Autonics
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J) Temperature Controllers
(K) SSRs
(L) Power Controllers
(M) Counters
(N) Timers
(O) Digital Panel Meters
(P) Indicators
(Q) Converters
(R) Digital Display Units
(S) Sensor Controllers
(T) Switching Mode Power Supplies
(U) Recorders
(V) HMIs
(W) Panel PC
(X) Field Network Devices
Compact Panel Meter
Dimensions
= =
58
44
(unit: mm)
48
24
~111
● Bracket ● Panel cut-out
Ln
I n
~99911~
I
23
jJ
48.6
45.2
p
22
36.3
~ ~
0
4 37 22
~
11.6
1F
Min. 37
10
21.1
I
Min. 60
+ 0.6
45
0
+ 0.3
0
22.2
Mounting
Panel
Max. 10mm
H
Panel boad tickness should be less than 10mm.
Autonics
O-47
Loading...