Autec CRXNH022 User Manual

Original instructions
DYNAMIC SERIES
Part D: CRX receiving unit
INDEX
1 Description ............................................................................................................ 2
1.1 Safety functions of the CRX receiving unit ....................................................... 3
2 Technical data ....................................................................................................... 3
3 Technical data sheet ............................................................................................. 3
4 Plates ..................................................................................................................... 4
5 Light signals .......................................................................................................... 4
5.1 POWER LED (green) ....................................................................................... 4
5.2 ALARM LED (red) ............................................................................................ 5
5.3 RUN LED (green) ............................................................................................. 5
5.4 ERR LED (red) ................................................................................................. 5
6 Malfunction signalled by the receiving unit ........................................................ 6
AUTEC LICRXE00-01
1 Description
Description
A mounting holes
B LED
C IDK connector (for address key)
D DIP switches
E DTK connector (for memory board)
LICRXE00-01
F Connector for cable control
G Plug or cable gland
BNC connector for external antenna kit
H
(optional)
J Fuse F1
K Technical data plate
L Radio remote control identi󰘰cation plate
AUTEC - Dynamic Series
Technical data 3
The receiving unit is interfaced with the machine through the outputs and their wiring and/or through a CAN network (of which it is a slave node). The CAN communication of the CRX receiving unit can be enabled or disabled. The machine manufacturer or who install the radio remote control on the machine determines whether the CAN communication is enabled or disabled. The STOP and SAFETY outputs are some of the receiving unit's outputs.
1.1 Safety functions of the CRX receiving unit
The SO1 and SO2 outputs may be either STOP (stop function) or SAFETY outputs (UMFS
function), according to the con󰘰guration of the receiving unit (see technical data sheet). If they are con󰘰gured as STOP outputs the UMFS safety function is not available. If they are con󰘰gured as SAFETY outputs both the UMFS and stop safety functions are
available.
2 Technical data
Power supply ........................................................................................................ 8-30V
Antenna ............................................................................................. internal or dedicated
Rated current of SO_1 and SO_2 outputs ........................................................ 2A (30V )
Rated current of digital outputs ........................................................................ 2A (30V )
Protection of power supply (resettable fuse) ............................................................... 1.3A
Protection of outputs (fuse F1) ....................................................... 10A (32V , autofuse)
Housing material .......................................................................................... PA6 (20% fg)
Protection degree ....................................................................................... IP66 (NEMA 4)
Dimensions ................................................................ 128x143x63mm (5.04x5.63x2.48In)
Weight ....................................................................................................... 0.65kg (1.43Lb)
3 Technical data sheet
The technical data sheet contains the wiring diagram showing the connection between the
receiving unit and the machine. It also contains the transmitting unit con󰘰guration and shows
the matching between commands sent and machine functions/movements.
Each technical data sheet must be 󰘰lled in, checked and signed by the installer, who is
responsible for a correct wiring. A technical data sheet must always be kept toghether with this manual (always keep a copy of the technical data sheet when it is used for administrative purposes).
The wiring of the receiving unit outputs must always re󰄉ect the wiring
indicated in the technical data sheet.