One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
k
www.panelook.com
Version and
Date
0.1
2008/03/10
0.2
2008/06/02
Product Specification
AU OPTRONICS CORPORATION
Record of Revision
Pag
e
All
First Edition for CustomerN/A
All
old formatnew format
5
2.1 Display Characteristics
1. No screen diagnoal description
2. weight 1900(max) TDB
3. No temperature range
6
View angel
Old descriptionNew DescriptionRemar
2.1 Display Characteristics
1.add screen diagnoal :
470.1 mm (18.51”)
2.weight 2000 (max)
3.add temperature range
operating 0~+50 [
o
storage (shipping) -20 to +60 [
M185XW01 V0
C]
o
C]
10
1. I/F PCB interface
FI-XB30SSRL-HF16 (JAE) / MSCKT2407P30B
()
2. Lamp connector
CVILUX CP0502SL090 / YEON HO
35001HS-02L
Mating Type: 35001WR-02LP
14
5.1.2 Signal Electrical
Characteristics
15
5.2 BL unit
(1)
1. I/F PCB Interface:
FI-XB30SSRL-HF16(JAE)/MSCKT2407P30HB(
)
2. Lamp connector
Deleted
(1)
(2) Note 8: The CCFL can work normally if the
PWM Dimming ratio range is from 20% to 100%
and the lamp current is 7.5mA
(2) Deleted Notes 8
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
q
www.panelook.com
Product Specification
AU OPTRONICS CORPORATION
21
6.4.1 Timing Characteristics
7.1 TFT LCD Module
24
25
7.2 Backlight Unit
Connector Name / Designation Lamp Connector / Backlight lamp
Manufacturer
Type Part Number
Mating Type Part Number
27
9.0 Shipping Label
CVILUX or YEON HO
CP0502SL090/35001HS-02L
CP0502P1ML0/35001W R-02LP
Connector Name / Designation Lamp Connector / Backlight lamp
Manufacturer
Type Part Number35001HS-02L
Mating Type Part Number35001WR-02LP
YEON HO
M185XW01 V0
0.3
2008/6/13
28,2
2D drawing –PCBA2D drawing –change PCBA size
9
216.4.1 Timing Characteristics
SignalItemSymbolMinTypMaxUnit
H-section
Note2 : Clock Fre
uency 90MHz(Max.)= 1416(H)*847(V)*75Hz
PeriodTh14 1616062047
ActiveTdisp(h)136613661366
BlankingTblk(h)50240681
Tclk
Tclk
Tclk
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Product Specification
AU OPTRONICS CORPORATION
1.0 Handling Precautions
1)Since front polarizer is easily damaged, pay attention not to scratch it.
2)Be sure to turn off power supply when inserting or disconnecting from input connector.
3)Wipe off water drop immediately. Long contact with water may cause discoloration or spots.
4)When the panel surface is soiled, wipe it with absorbent cotton or other soft cloth.
5)Since the panel is made of glass, it may break or crack if dropped or bumped on hard
surface.
6)Since CMOS LSI is used in this module, take care of static electricity and insure human earth
when handling.
7)Do not open or modify the Module Assembly.
8)Do not press the reflector sheet at the back of the module to any directions.
9)In case if a Module has to be put back into the packing container slot after once it was taken
M185XW01 V0
out from the container, do not press the center of the CCFL reflector edge. Instead, press at
the far ends of the CCFL Reflector edge softly. Otherwise the TFT Module may be damaged.
10) At the insertion or removal of the Signal Interface Connector, be sure not to rotate nor tilt the
Interface Connector of the TFT Module.
11) After installation of the TFT Module into an enclosure, do not twist nor bend the TFT Module
even momentary. At designing the enclosure, it should be taken into consideration that no
bending/twisting forces are applied to the TFT Module from outside. Otherwise the TFT
Module may be damaged.
12) Cold cathode fluorescent lamp in LCD contains a small amount of mercury. Please follow
local ordinances or regulations for disposal.
13) Small amount of materials having no flammability grade is used in the LCD module. The LCD
module should be supplied by power complied with requirements of Limited Power Source
(IEC60950 or UL1950), or be applied exemption.
14) The LCD module is designed so that the CCFL in it is supplied by Limited Current Circuit
(IEC60950 or UL1950). Do not connect the CCFL in Hazardous Voltage Circuit.
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Product Specification
AU OPTRONICS CORPORATION
M185XW01 V0
2.0 General Description
This specification applies to the 18.5 inch-wide Color a-Si TFT-LCD Module M185XW01.The
display supports the WXGA - 1366(H) x 768(V) screen format and 16.7M colors (RGB 6-bits +
Hi-FRC data). All input signals are 1-channel LVDS interface and this module doesn ’t contain an
inverter board for backlight.
2.1 Display Characteristics
The following items are characteristics summary on the table under 25 condition:
ITEMSUnitSPECIFICATIONS
Screen Diagonal[mm]
Active Area[mm]409.8 (H) x 230.4 (V)
Pixels H x V1366(x3) x 768
Pixel Pitch[um]300 (per one triad) × 300
Pixel ArrangementR.G.B. Vertical Stripe
Display ModeTN Mode, Normally White
White Luminance ( Center )[cd/m2]
Contrast Ratio1000 (Typ.)
Optical Response Time[msec]5ms (Typ., on/off)
470.1(18.51”)
2
300 cd/m
(@ 7.5mA(Typ.)
Nominal Input Voltage VDD[Volt]+5.0 V (Typ)
Power Consumption
(VDD line + CCFL line)
[Watt]17 W (Typ.)
(without inverter, all black pattern)
Weight[Grams]2000 (Max)
Physical Size[mm]430.37 (W) x 254.6 (H) Typ. x 16.5 (D) Max
Electrical InterfaceOne channel LVDS
Support Color16.7M colors (RGB 6-bit + Hi_FRC )
Surface TreatmentAnti-Glare, 3H
Temperature Range
Operating
Storage (Shipping)
o
C]
[
o
C]
[
0 to +50
-20 to +60
RoHS ComplianceRoHS Compliance
document version 0.36
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Product Specification
AU OPTRONICS CORPORATION
M185XW01 V0
2.2 Optical Characteristics
The optical characteristics are measured under stable conditions at 25 :
ItemUnitConditionsMin.Typ.Max.Note
Horizontal(Right)
Viewing Angle[degree]
Contrast ratioNormal Direction6001000-
Response Time[msec]
Color / Chromaticity
Coordinates (CIE)
Color Coordinates (CIE) White
Central Luminance[cd/m2]240300-
Luminance Uniformity
Crosstalk (in 60Hz)
Flicker
[%]
[%]
dB
CR = 10(Left)
Vertical(Up)
CR = 10(Down)
Raising Time (TrR)
Falling Time (TrF)
Raising + Falling
Red x
Red y
Green x
Green y
Blue x
Blue y
White x
White y
150170
140160
-
-
-
0.6180.6480.678
0.3090.3390.369
0.2620.2920.322
0.5730.6030.633
0.1130.1430.173
0.0400.0700.100
0.2830.3130.343
0.2990.3290.359
7580
3.65.7
1.42.3
58
-
-
-
-
-
1.5
-20
2
3
4
5
6
7
8
9
document version 0.37
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Product Specification
AU OPTRONICS CORPORATION
M185XW01 V0
Note 1: Measurement method
The LCD module should be stabilized at given temperature for 30 minutes to avoid abrupt
temperature change during measuring (at surface 35) . In order to stabilize the luminance, the
measurement should be executed after lighting Backlight for 30 minutes in a stable, windless and
dark room.
Photo detector
Measured distance
LCD Panel
Center of the screen
TFT-LCD
Note 2: Definition of viewing angle measured by ELDIM (EZContrast 88)
Viewing angle is the measurement of contrast ratio 10, at the screen center, over a 180 °
horizontal and 180° vertical range (off-normal viewing angles). The 180 ° viewing angle range is
broken down as follows; 90° (θ) horizontal left and right and 90° (Φ) vertical, high (up) and low
(down). The measurement direction is typically perpendicular to the display surface with the
screen rotated about its center to develop the desired measurement viewing angle.
documentversion0.38
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Product Specification
AU OPTRONICS CORPORATION
M185XW01 V0
Note 3: Contrast ratio is measured by TOPCON SR-3
Note 4: Definition of Response time measured by Westar TRD-100A
The output signals of photo detector are measured when the input signals are changed from “Full
Black” to “Full White” (rising time, Tr
), and from “Full White” to “Full Black” (falling time, TfF),
R
respectively. The response time is interval between the 10% and 90% (1 frame at 60 Hz) of
amplitudes.
%
Optical
Optical
response
response
100
100
90
10
10
%
W hiteBla ck
0
0
Tr
Tr
F
F
Black
1 Frame1 Frame
Tr
Tr
R
R
White
+ TfF = 5 msec (typ.).
Tr
R
Note 5: Color chromaticity and coordinates (CIE) is measured by TOPCON SR-3
Note 6: Central luminance is measured by TOPCON SR-3
Note 7: Luminance uniformity of these 9 points is defined as below and measured by
TOPCON SR-3
Uniformity =
9)-(1points9inLuminanceMinimum
9)-(1Points9inLuminanceMaximum
Note 8: Crosstalk is defined as below and measured by TOPCON SR-3
document version 0.39
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
l
www.panelook.com
Product Specification
AU OPTRONICS CORPORATION
CT = | YB – YA | / YA 100 (%)
Where
YA = Luminance of measured location without gray level 0 pattern (cd/m2)
YB = Luminance of measured location with gray level 0 pattern (cd/m2)
M185XW01 V0
Note 9: Test Patern: Subchecker Pattern measured by TOPCON SR-3
RGBRGB
Gray Level = L127
R GBRGB
RGBRGB
Gray Level = L0
Method: Record dBV & DC value with TRD-100
Amplitude
DC
log20(dB)Flicker=
DC
AC
Time
Hz)30Level(atAC
Leve
document version 0.310
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Product Specification
AU OPTRONICS CORPORATION
M185XW01 V0
3.0 Functional Block Diagram
The following diagram shows the functional block of the 18.5 inch Color TFT-LCD Module:
LVD
+5V
Connector
LVDS
Receiver
AUO
Timing
Controller
RSDS
Transmitter
G1
G768
Y-Driver IC
TFT-LCD
1366(x3) x 768
Pixels
-Driv
r I
DC/DC
Converter
Gamma
Correction
I/F + X-PCB
DC
I/F PCB Interface:
FI-XB30SSRL-HF16(JAE)/MSCKT2407P30HB()
Mating Type:
FI-X30HL (JAE)(Locked Type)
D1D4098
2 CCFL
Inverter
document version 0.311
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Product Specification
AU OPTRONICS CORPORATION
4.0 Absolute Maximum Ratings
Absolute maximum ratings of the module are as following:
4.1 TFT LCD Module
ItemSymbolMinMaxUnitConditions
Logic/LCD Drive
Voltage
4.2 Backlight Unit
ItemSymbolMinMaxUnitConditions
CCFL CurrentICFL
4.3 Absolute Ratings of Environment
VDD4.5+5.5[Volt]Note 1,2
3.08
M185XW01 V0
[mA] rmsNote 1,2
ItemSymbolMin.Max.UnitConditions
Operating TemperatureTOP0+50 [oC]
Operation HumidityHOP590[%RH]
Storage TemperatureTST-20+60 [oC]
Storage HumidityHST
590
[%RH]
Note 1: With in Ta (25)
Note 2: Permanent damage to the device may occur if exceeding maximum values
Note 3: For quality perfermance, please refer to AUO IIS(Incoming Inspection Standard).
Note 3
Operating RangeStorage Range
document version 0.312
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Product Specification
M185XW01 V0
AU OPTRONICS CORPORATION
5.0 Electrical characteristics
5.1 TFT LCD Module
5.1.1 Power Specification
Input power specifications are as following:
SymbolParameterMinTypMaxUnitConditions
VDD
IDDInput Current
PDDVDD Power
IRushInrush Current
Logic/LCD Drive
Voltage
4.5
-
-
-
5.0
1.2
5.5
1.5
68.25[Watt]
[Volt]+/-10%
[A]
VDD= 5.0V, All Black Pattern
At 60Hz,
VDD= 5.0V, All Black Pattern
At 60Hz
-3[A]Note 1
VDDrp
Allowable Logic/LCD
Drive Ripple Voltage
-
-200[mV] p-p
Note 1: Measurement conditions:
The duration of rising time of power input is 470us.
(High to Low)
Control
Signal
SW1
SW MAG-SPST
12
+12.0V
+5.0V
C2
1uF/25V
R1
47K
R2
1K
VR1
47K
D6
D5
D2S
D1
G
C3
0.01uF/25V
Q3
AO6402
D2SD1D5
G
D6
Q3
AO6402
VDD= 5.0V, All Black Pattern
At 60Hz
F1
VCC
C1
1uF/16V
(LCD Module Input)
document version 0.313
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Product Specification
AU OPTRONICS CORPORATION
M185XW01 V0
5.1.2 Signal Electrical Characteristics
Input signals shall be low or Hi-Z state when VDD is off. Please refer to specifications of
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Product Specification
AU OPTRONICS CORPORATION
M185XW01 V0
5.2 Backlight Unit
Parameter guideline for CCFL Inverter is under stable conditions at 25 (Room Temperature):
ParameterMin.Typ.Max.UnitNote
CCFL Standard Current (ISCFL) 7.0
CCFL Operation Current (IRCFL)
CCFL Frequency (FCFL)405080[KHz]
CCFL Ignition Voltage (ViCFL, Ta= 0 )1650--[Volt] rms
CCFL Ignition Voltage (ViCF, Ta= 25)1250- -[Volt] rms
CCFL Operation Voltage (VCFL)-
CCFL Power Consumption (PCFL)-1112.1[Watt]
3.07.5
7.58.0
700
(@7.5mA)
[mA] rms
8.0
880[Volt] rms
[mA] rms
2
3, 4
5
6
CCFL Life Time (LTCFL)
40,00050,000
-[Hour]
7
Note 1: Typ. values are AUO recommended design values.
*1 All of characteristics listed are measured under the condition using the AUO test inverter.
*2 It is recommended to check the inverter carefully. Sometimes, interfering noise stripes appear
on the screen, and substandard luminance or flicker at low power may happen.
*3 While designing an inverter, it is suggested to check safety circuit very carefully. Impedance of
CCFL, for instance, becomes more than 1 [M ohm] when CCFL is damaged.
*4 Generally, CCFL has certain delay time after applying kick-off voltage. It is recommended to
keep on applying kick-off voltage for 1 [Sec] until discharge.
*5 Reducing CCFL current will increase CCFL discharge voltage and generally increases CCFL
discharge frequency. So all the parameters of the inverter should be carefully designed so the
inverter will not produce too much leakage current from high-voltage output.
*6 For designing CCFL current, it is highly recommanded to use symmetric and consistent
sinusoidal wave for each CCFL input current with asymmetric ration of 10% or less in both
postive area and negative area (ie. 0.9*2*I
< I1& I2< 1.1*2*I
rms
) as refer to the following
rms
diagram, otherwise proper CCFL functionality cannot be guarantied.
document version 0.315
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Product Specification
AU OPTRONICS CORPORATION
M185XW01 V0
Note 2: CCFL standard current is measured by continue mode inverter at 25 2.
Note 3: CCFL discharge frequency should be carefully determined to avoid interference between
inverter and TFT LCD.
Note 4: The frequency range will not affect lamp life and reliability characteristics.
Note 5: CCFL inverter should be able to release power that has generating capacity exceeding
1650 volt. Lamp units need minimum voltage, 1650 Volt, for ignition.
Note 6: The variance of CCFL power consumption is ±10%. (IRCFL × VCFL × 2 = PCFL)
Note 7: Definition of life time: brightness becomes 50%. The minimum life time of CCFL unit is on
the condition of 7.5mA CCFL current and 252.
document version 0.316
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Product Specification
AU OPTRONICS CORPORATION
M185XW01 V0
6.0 Signal Characteristic
6.1 Pixel Format Image
Following figure shows the relationship of the input signals and LCD pixel format.
121365 1366
1st Line
R G B R G B
R G B R G B
768 Line
R G B R G B
R G B R G B
document version 0.317
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
6.2 The input data format
Product Specification
AU OPTRONICS CORPORATION
LVDS Data Mapping of NS Format
M185XW01 V0
LVDS Data Mapping of JEIDA Format
Note1: Normally, DE, VS, HS on EVEN channel are not used.
Note2: 8-bits signal input.
document version 0.318
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Product Specification
AU OPTRONICS CORPORATION
M185XW01 V0
6.3 Signal Description
The module using one LVDS receiver SN75LVDS82(Texas Instruments). LVDS is a
differential signal technology for LCD interface and high speed data transfer device. LVDS
transmitters shall be SN75LVDS83(negative edge sampling). The first LVDS port(RxOxxx)
transmits odd pixels while the second LVDS port(RxExxx) transmits even pixels.
15RXCLKIN+Positive LVDS differential data input (clock)
16GNDPower Ground
17RXIN3-Negative LVDS differential data input (3)
18RXIN3+Positive LVDS differential data input (3)
19GNDPower Ground
20NCNo contact (For AUO internal use)
21NCNo contact (For AUO internal use)
22NCNo contact (For AUO internal use)
23GNDPower Ground
24GNDPower Ground
25GNDPower Ground
26VCC+5V power supply
27VCC+5V power supply
28VCC+5V power supply
29VCC+5V power supply
30VCC+5V power supply
Note1: Start from left side
document version 0.319
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Product Specification
AU OPTRONICS CORPORATION
M185XW01 V0
1
NC
Note2: Input signals of clock shall be the same timing.
Note3: Please follow TV VESA Pin Assignment.
30
VCC
document version 0.320
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Product Specification
AU OPTRONICS CORPORATION
M185XW01 V0
6.4 Timing Characteristics
Basically, interface timing described here is not actual input timing of LCD module but close to
output timing of SN75LVDS82DGG (Texas Instruments) or equivalent.
Signal
Item
SymbolMinTypMaxUnit
PeriodTv7768081023Th
V-section
H-section
ActiveT disp(v)768768768
BlankingTblk(v)840255
PeriodTh141616062047
ActiveTdisp(h)136613661366
BlankingTblk(h)50240681
Th
Th
Tclk
Tclk
Tclk
PeriodTclk-12.8-ns
Clock
Frame Rate
Frequency
Frame Rate
Freq
F
-7890MHz
506075Hz
Note1 : DE mode only
Note2 : Clock Frequency 90MHz(Max.)= 1416(H)*847(V)*75Hz
document version 0.321
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
6.5 Timing diagram
Product Specification
AU OPTRONICS CORPORATION
M185XW01 V0
document version 0.322
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Product Specification
AU OPTRONICS CORPORATION
M185XW01 V0
6.6 Power ON/OFF Sequence
VDD power and lamp on/off sequence are as follows. Interface signals are also shown in the
chart. Signals from any system shall be Hi-Z state or low level when VDD is off.
Parameter
Value
Min.Typ.Max.
T10.5-10[msec]
T204050[msec]
T3200--[msec]
T4200--[msec]
T50.51650[msec]
T6--100[msec]
T71000--[msec]
document version 0.323
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
Unit
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Product Specification
AU OPTRONICS CORPORATION
M185XW01 V0
7.0 Connector & Pin Assignment
Physical interface is described as for the connector on module. These connectors are capable of
accommodating the following signals and will be following components.
7.1 TFT LCD Module
Connector Name / DesignationInterface Connector/ Interface card
ManufacturerJAE or STM
Type Part NumberFI-XB30SSRL-HF16(JAE)/MSCKT2407P30HB(STM)
Mating Housing Part Number
FI-X30HL(JAE) (Locked Type)
FI-X30H (JAE)(Unlocked Type)
7.1.1 Pin Assignment
Pin#Signal NamePin#Signal Name
1NC2NC
3NC4GND
5
7
9
11
13
15
17
19
RXIN0-
GND
RXIN1+
RXIN2-
GND
RXCLKIN+
RXIN3-
GND
6
8
10
12
14
16
18
20NC
21NC22NC
23
25
GND
GND
24
26VCC
27VCC28VCC
RXIN0+
RXIN1-
GND
RXIN2+
RXCLKIN-
GND
RXIN3+
GND
29VCC30VCC
document version 0.324
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Product Specification
AU OPTRONICS CORPORATION
M185XW01 V0
7.2 Backlight Unit
Physical interface is described as for the connector on module. These connectors are capable of
accommodating the following signals and will be following components.
Connector Name / DesignationLamp Connector / Backlight lamp
Manufacturer
Type Part Number
Mating Type Part Number
YEON HO
35001HS-02L
35001WR-02LP
7.2.1 Signal for Lamp connector
Upper
Lower
Connector No.Pin No.InputColorFunction
CN1
Connector No.Pin No.InputColorFunction
CN2
1Hot1PinkHigh Voltage (Lamp1)
2Cold1WhiteLow Voltage(Lamp1)
1Hot1PinkHigh Voltage(Lamp2)
2Cold1WhiteLow Voltage (Lamp2)
document version 0.325
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Product Specification
AU OPTRONICS CORPORATION
8.0 Reliability Test
Environment test conditions are listed as following table.
ItemsRequired Condition
Temperature Humidity Bias (THB)Ta= 50, 80%RH, 300hours
High Temperature Operation (HTO)Ta= 50, 50%RH, 300hours
Low Temperature Operation (LTO)Ta= 0, 300hours
High Temperature Storage (HTS)Ta= 60, 300hours
Low Temperature Storage (LTS)Ta= -20, 300hours
Acceleration: 1.5 Grms
Vibration Test
(Non-operation)
Wave: Random
Frequency: 10 - 200 Hz
Sweep: 30 Minutes each Axis (X, Y, Z)
M185XW01 V0
Note
Acceleration: 50 G
Shock Test
(Non-operation)
Drop TestHeight: 60 cm, package test
Thermal Shock Test (TST)-20/30min, 60/30min, 100 cycles
On/Off TestOn/10sec, Off/10sec, 30,000 cycles
ESD (Electro Static Discharge)
Altitude Test
Wave: Half-sine
Active Time: 20 ms
Direction: X, Y, Z (one time for each Axis)
1
Contact Discharge: ± 8KV, 150pF(330Ω ) 1sec,
8 points, 25 times/ point.
2
Air Discharge: ± 15KV, 150pF(330Ω ) 1sec
8 points, 25 times/ point.
Operation:10,000 ft
Non-Operation:30,000 ft
Note 1: The TFT-LCD module will not sustain damage after being subjected to 100 cycles of rapid
temperature change. A cycle of rapid temperature change consists of varying the temperature from
0
-2
to 60, and back again. Power is not applied during the test. After temperature cycling, the
unit is placed in normal room ambient for at least 4 hours before power on.
Note 2: EN61000-4-2, ESD class B: Certain performance degradation allowed
No data lost
Self-recoverable
No hardware failures.
document version 0.326
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Product Specification
AU OPTRONICS CORPORATION
9.0 Shipping Label
The label is on the panel as shown below:
Note 1: For Pb Free products, AUO will add for identification.
M185XW01 V0
Note 2: For RoHS compatible products, AUO will add
Note 3: For China RoHS compatible products, AUO will add
for identification.
for identification.
Note 4: The Green Mark will be presented only when the green documents have been ready by
AUO Internal Green Team.
document version 0.327
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Ver 0.1
10.0 Mechanical Characteristics
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Global LCD Panel Exchange Center
www.panelook.com
Ver 0.1
One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory!
www.panelook.com
Loading...
+ hidden pages