11.4 National Test Lab Requirement .........................................................................................27
AUO Confidential For DATAMODUL Internal Use Only / 2012/12/12
document version 1.0
2
Product Specification
Data Modul AG - www.data-modul.com
3
AU OPTRONICS CORPORATION
G215HVN01.0
Record of Revision
Version and Date
0.1 2011/11/03
Page
Old description New Description Remark
All First Edition All
26
0.2 2012/02/03
1.0 2012/11/23
5, 15
6, 11
15
Operating Temp: 0 to +50C Operating Temp: 0 to +60C
AUO Confidential For DATAMODUL Internal Use Only / 2012/12/12
document version 1.0
3
Product Specification
Data Modul AG - www.data-modul.com
4
AU OPTRONICS CORPORATION
G215HVN01.0
1. Operating Precautions
1) Since front polarizer is easily damaged, pay attention not to scratch it.
2) Be sure to turn off power supply when inserting or disconnecting from input connector.
3) Wipe off water drop immediately. Long contact with water may cause discoloration or spots.
4) When the panel surface is soiled, wipe it with absorbent cotton or other soft cloth.
5) Since the panel is made of glass, it may break or crack if dropped or bumped on hard surface.
6) Since CMOS LSI is used in this module, take care of static electricity and insure human earth
when handling.
7) Do not open or modify the Module Assembly.
8) In case if a Module has to be put back into the packing container slot after once it was taken out
from the container, take it easily, or the TFT Module may be damaged.
9) At the insertion or removal of the Signal Interface Connector, be sure not to rotate nor tilt the
Interface Connector of the TFT Module.
10) After installation of the TFT Module into an enclosure, do not twist nor bend the TFT Module
even momentary. At designing the enclosure, it should be taken into consideration that no
bending/twisting forces are applied to the TFT Module from outside. Otherwise the TFT Module
may be damaged.
11) Small amount of materials having no flammability grade is used in the LCD module. The LCD
module should be supplied by power complied with requirements of Limited Power Source
(IEC60950 or UL1950), or be applied exemption.
12) Severe temperature condition may result in different luminance, response time and LED life
time.
13) The data on this specification sheet is applicable when LCD module is placed in landscape
position.
14) Continuous displaying fixed pattern may induce image sticking. It is recommended to use
screen saver or shuffle content periodically if fixed pattern is displayed on the screen.
AUO Confidential For DATAMODUL Internal Use Only / 2012/12/12
document version 1.0
4
Product Specification
Data Modul AG - www.data-modul.com
5
AU OPTRONICS CORPORATION
G215HVN01.0
2. General Description
This specification applies to the 21.5 inch-wide Color TFT-LCD Module G215HVN01.0. The
display supports the Full HD - 1920(H) x 1080(V) screen format and 16.7M colors (RGB 8-bits
data). All input signals are dual channel LVDS interface.
LED driver board is included. G215HVN01.0 is designed for industrial display applications.
2.1 Display Characteristics
The following items are characteristics summary on the table under 25℃ condition:
ITEMS Unit SPECIFICATIONS
Screen Diagonal [mm] 546.86(21.53”)
Active Area [mm] 476.64 (H) x 268.11 (V)
Pixels H x V 1920(x3) x 1080
Pixel Pitch [um] 248.25 (per one triad) ×248.25
Pixel Arrangement R.G.B. Vertical Stripe
Display Mode VA Mode, Normally Black
White Luminance ( Center ) [cd/m2] 300 (Typ.)
Contrast Ratio 5000 (Typ.)
Optical Response Time [msec] 16 ms (Typ., on/off)
Nominal Input Voltage [Volt] +5.0 V
Backlight Input Voltage [Volt] +12.0 V
Power Consumption [Watt] 23 W (Typ. Cell 3.5 + LED 19.2)
AUO Confidential For DATAMODUL Internal Use Only / 2012/12/12
document version 1.0
[oC]
[oC]
0 to +60
-20 to +60
5
Product Specification
Data Modul AG - www.data-modul.com
6
AU OPTRONICS CORPORATION
G215HVN01.0
2.2 Optical Characteristics
The optical characteristics are measured under stable conditions at 25℃:
Item Unit Conditions Min. Typ. Max. Note
Viewing Angle
[degree] Horizontal (Right)
CR = 10 (Left)
[degree]
Vertical (Upper)
CR = 10 (Lower)
75
75
75
75
89
89
89
89
-
-
1, 2
-
-
Contrast ratio Normal Direction 3000 5000 - 3
Raising Time (TrR) - 10 12
Response Time [msec]
Falling Time (TrF) - 6 7
4
Raising + Falling - 16 19
Red x 0.589 0.639 0.689
Red y 0.283 0.333 0.383
Color / Chromaticity
Coordinates (CIE)
Green x 0.284 0.334 0.384
Green y 0.573 0.623 0.673
5
Blue x 0.105 0.155 0.205
Blue y 0.000 0.048 0.098
Color Coordinates (CIE) White
White x 0.263 0.313 0.363
White y 0.279 0.329 0.379
Central Luminance [cd/m2] 240 300 - 6
Luminance Uniformity [%] 75 80 - 7
Crosstalk (in 60Hz) [%] 1.5 8
Flicker dB -20 9
AUO Confidential For DATAMODUL Internal Use Only / 2012/12/12
document version 1.0
6
Product Specification
Center of the screen
Data Modul AG - www.data-modul.com
7
AU OPTRONICS CORPORATION
G215HVN01.0
Note 1: Measurement method
Before measuring, the LCD module should be turn on 30 minutes at room temperature. In order to
stabilize the luminance, the measurement should be executed after lighting Backlight for 30
minutes in a stable, windless and dark room.
Photo detector
Measured distance
N
ote 2: Definition of viewing anglemeasured by ELDIM (EZContrast 88)
Viewing angle is the measurement of contrast ratio ≧10, at the screen center, over a 180°
horizontal and 180° vertical range (off-normal viewing angles). The 180° viewing angle range is
broken down as follows; 90° (θ) horizontal left and right and 90° (Φ) vertical, high (up) and low
(down). The measurement direction is typically perpendicular to the display surface with the screen
rotated about its center to develop the desired measurement viewing angle.
AUO Confidential For DATAMODUL Internal Use Only / 2012/12/12
document version 1.0
7
Product Specification
100
90
10
0
response
T
100
10
0
response
1 Frame
1 Frame
T
Data Modul AG - www.data-modul.com
8
AU OPTRONICS CORPORATION
G215HVN01.0
Note 3: Contrast ratio is measured by TOPCON SR-3
Note 4: Definition of Response time measured by Westar TRD-100A
The output signals of photo detector are measured when the input signals are changed from “Full
Black” to “Full White” (rising time, TrR), and from “Full White” to “Full Black” (falling time, TrF),
r
espectively. The response time is interval between the 10% and 90% (1 frame at 60 Hz) of
amplitudes.
%
Optical
Optical
%
White
rF
Black
Black
rR
White
TrR + TrF = 16 msec (typ.).
N
ote 5: Color chromaticity and coordinates (CIE) is measured by TOPCON SR-3
Note 6: Central luminance is measured by TOPCON SR-3
Note 7: Luminance uniformity of these 9 points is defined as below and measured by
TOPCON SR-3
AUO Confidential For DATAMODUL Internal Use Only / 2012/12/12
Uniformity =
document version 1.0
9)-(1 points 9in LuminanceMinimum
9)-(1 Points 9in LuminanceMaximum
8
Loading...
+ 20 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.