CONTENT
8200T
1.
Introduction
2.
Specification
3.
Assembly Sketch
4.
Schematic Diagram
5.
6.
7.
8.
9.
ia
Wir ng Di gram
screen of Bottom
Silk Top
Maintenance Alignment Procedure
Assembly Parts List
Electronic Parts List
/
1
2-4
5
6-8
9
10-13
14
15-16
17-22
INTRODUCTION
No part of this document may be reproduced or transmitted in any form or by any means,electronic or
mechanical, for any purpose, without the express written permission of International Audio Group
Limited (IAG)
This manual is for the exclusive use of IAG, its approved distributors and approved UK service agents.
No part of this manual shall be transferred to any other party without the express written permission of
IAG.
It is the responsibility of the user to ensure that all the information contained in this manual is current.
Notification for new issues of this manual and minor updates will be given via the IAG web-site or on
request.
This manual has been prepared with the greatest care, it is intended for information only and no liability
shall be accepted for errors or changes to specification.
For further service information, parts lists and updates, please contact our web-site at
www.international audio group.com .
C
2011 International Audio Group Limited. All rights reserved.
8200T
1
SPECIFICATION
Test conditions
1): Power supply voltage & Frequency (need to same as the product code)
CCCType 220V/50Hz .+/-10%
CEType 230V/50Hz .+/-10%
2): Temperature & Humidity
Temperature 5 ~45
Humidity 50 ~90 % RH
3):a. Set Volume at max
b.take on the EQ model
c. set the bass ,balance filter at no use model
d.take off the EQ model
4):testbyatuotestsystem
1.FM Section
Frequency Range
CE&UL 87.5-108MHz Step 50KHz
°C
Measurement item FREQ Unit Limit Remarks
1 Usable sensitivity MONO IHF(3% THD) 98MHz dBu ≤18
2 S/N RATIO MONO (60dBU IHF A wtd) 98MHz dB ≥72
3 S/N RATIO STEREO (60dBU IHF A wtd) 98MHz dB ≥66
4
5
6
7
8
9 Channel Separation (60dBu IHF A wtd) 98MHz dB ≥32
10
11 FM output Level 98MHz V 1.8 to 2.2
12 Output DC offset 98MHz mV ≤3
MONO THD (60dBu IHF wtd)
L=R,C=40KHz Dev
STEREO THD (60dBu IHF wtd)
L=R,C=40KHz Dev
IF Rejection
(10.7MHz) (ref to item1)
Image Rejection
(119.4MHz) (refer to item1)
Frequency response 20Hz-15KHz (1KHz
Ref, UL=75uS,CE=50uS)
Alternate channel selectivity
(+/400KHz,IHF)
RDS dec ode s ensitivity , 4%
DEVIATION
98MHz % 0.4
98MHz % 0.6
98MHz dB
98MHz dB
98MHz dB
98MHz dB ≥60
57KHz dBu
≥70
≥40
≤-3
≤3213
8200T
2
2.AM Section
Frequency Range
UL 530-1710KHz Step 10KHz
Me asureme nt item FREQ(KHz) Unit Limit Re marks
SPECIFICATION
Usablesensitivity(400Hz,20
1
2 S/N RATIO (5mV input) 999/1000 dB ≥38
3 THD (5mV input) 999/1000 % ≤3
4 Selectivity 999/1000 dB ≥17
5 Output (30%,10mV) 999/1000 V
dB,direct input)
Frequency response
100-2.3KHz(400Hz,5mV)
999/1000 dBuV ≤32
999/1000 dB
3.DAB Section
Mea surement item Measurement condition Unit Limit Remarks
1
2THD(1KHz)
Frequency
response(42-20KHz)
Play G06P01T1.PLY 42HZ20KHZ signal
Play G06P01T1.PLY, 1KHZ
signal
1-1.5
+/-36
dB -3
%0.2
8200T
3 Output Level
4S/N
5 sensitivity
6 Channel Separation
Play G06P01T1.PLY, 1KHZ
signal
Play G06P01T1.PLY,1KHZ
signal(OFF RF)
Play G06P01T1.PLY, 1KHZ
signal
Play G06P01T1.PLY,
1KHZ signal (OFF RF)
V 1.4±0.2
dB ≥65
dB ≥80
dB ≥60
3
Functional
Measurement item Measurement condition Unit Limit Remarks
1 Remote control distance 30℃ M ≥5
Operating voltage in range
2
3
4 Operating Temperature ℃ 0to+45
5 IR output voltage Level V 2.8V to 3.5V
6
from AC voltage CE
Operating voltage in range
from AC voltage UL
IR accept input volaget
Range
AC230V % ±10
AC120V % ±10
V3to12
SPECIFICATION
7 COAXIAL output Level 75 OHM loading V 0.5 to 1
8 COAXIAL THD 1KHz % ≤0.2
8200T
4