Series 1500™
Intercom Systems
Patent D/528,534
Installer’s Reference Guide
Contents
Introduction |
2 |
Component Overview |
2 |
Cable Fabrication |
2 |
Installation Overview |
|
One-On-One System |
3 |
Small Audio System |
3 |
Audio/Video System |
4 |
Installing Components |
|
The Hub |
5 |
The Counter Station |
6 |
The Lane Station |
7 |
Testing Your Installation |
8 |
Troubleshooting Tips and |
|
Common Issues |
8 |
Hub Diagrams |
|
Audio Hub (1509) |
9 |
Audio/Video Hub (1510) |
10 |
Expanding Capacity |
11 |
Operator Instructions |
12 |
1550 Field Setup Tool |
|
System Calibration & Setup |
13 |
Setup Menu Map |
13 |
Example Configuration |
15 |
The Memory Card
Memory Card Notes 16
Firmware Upgrade Procedure 16
Tools and Supplies
•Cat 5 network cable tester
•RJ-45 plug crimping tool (Audio Authority recommends EZ-RJpro crimp tool)
•Category 5e or 6 UTP cable and RJ-45 terminations (Audio Authority recommends EZ-RJ-45 connectors)
•18mm open-end wrench (for boom mic)
•Model 1550 Field Setup LCD Display Tool
Installing and Using the
Series 1500™ Intercom Systems
Series 1500™ Intercoms enable clear two-way communications in retail service businesses. Two-way video is integrated with highperformance audio to provide a complete intercommunication solution over a single Category 5e or 6 UTP cable. The versatile Model 1500 Counter Station, which can access up to 16 lanes, and the Model 1520 Lane Station can be connected directly to each other in a one-on-one system, or multiples of each can be networked using a Model 1509 Hub for up to two-on-four audio performance or Series 1510 Hub for multi-lane systems (See example diagrams on the following pages). Series 1510 Hubs can support up to 8 Counter Stations on 16 lanes.
Series 1500 System Components
CounterAudio Station |
1500 |
Counter VideoAdd-on |
1502 |
2-on-4Audio Hub |
1509 |
4-on-4Audio/Video Hub |
1510 |
4-on-8Audio/Video Hub |
1511 |
8-on-12Audio/Video Hub |
1512 |
8-on-16Audio/Video Hub |
1513 |
(See page 11 for Hub configurations)
4-counter plug-in card |
1515 |
4-lane plug-in card |
1516 |
System plug-in card |
1517 |
Lane Station |
1520 |
CompleteA/V Station |
1522 |
Customer VideoAdd-On |
1523 |
Surface-mount handset |
1540 |
Flush-mount handset |
1541 |
Wireless headset |
1542 |
Wired headset |
1543 |
Field Setup LCD |
1550 |
Universal 1APower Supply |
571-013 |
Boom Microphone 631-026 |
|
External microphone kit |
631-029 |
External 3”, 4 ohm speaker |
631-030 |
3Amp UL DC power supply |
805-016 |
Cable Fabrication
Terminate the ends of each cable with RJ-45 modular plugs using the EIA 568B pinout (paired 1- 2, 3-6, 4-5, and 7-8). Pre-made network cables may also be used for shorter runs. Test all cables with a network cable tester. Note: Cat 5e and Cat 6 are also acceptable cable types.
Pin 1 |
RJ-45 Plug |
|
|
|
Pins facing up, |
|
clip pointing away. |
WHITE / ORANGE ORANGE WHITE / GREEN BLUE WHITE / BLUE GREEN |
WHITE / BROWN BROWN |
WHITE / ORANGE ORANGE WHITE / GREEN BLUE WHITE / BLUE GREEN |
WHITE / BROWN BROWN |
||||||||||||||||||||||||||||||||
1 2 3 4 5 6 7 8 |
1 2 3 4 5 6 7 8 |
||||||||||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Cat 5
2 Audio Authority® Series 1500 Installer’s Reference Guide
1x1 Installation
The simplest system configuration involves only one counter station connected directly to one lane station (no hub). This configuration can be audio-only or audio/video. Run a length of Cat 5 cable from the counter location to the lane location; the cable can be up to 1,000 feet long. See “Installing Components” for detailed instructions.
|
|
POWER |
AUDIO/VIDEO |
|
|
COUNTER STATION |
|
|
|
MIC |
CUSTOMER |
|
VIDEO ADD-ON |
|
|
|
|
|
SPEAKER |
LANE STATION |
|
CALL BUTTON |
LOCATED IN |
|
DRIVE UP UNIT |
|
|
|
|
POWER |
TRAFFIC SENSING |
|
|
REMOTE CONTROL RELAY |
|
|
ARMORED HANDSET |
MODEL 1523 |
|
|
|
MODEL 1500 |
|
|
WITH 1502 |
|
MODEL |
HEADSET |
|
1520 |
2x4 Audio Installation
The Model 1509 Audio Hub allows one or two Model 1500 Audio Counter Stations to serve up to four 1520 Lane Stations. 1509 Hub configurations must be audio-only. Run a length of Cat 5 cable from each Counter Station to the Hub. Run a length of Cat 5 cable from the Hub to each Lane Station. The total cable length from Counter Station to Lane Station can be up to 1,000 feet. See “Installing Components” for detailed instructions.
POWER
|
|
MIC |
|
|
|
SPEAKER |
LANE STATION |
|
|
CALL BUTTON |
LOCATED IN |
|
|
DRIVE UP UNIT |
|
|
|
|
|
|
|
TRAFFIC SENSING |
|
|
AUDIO |
REMOTE CONTROL RELAY |
|
|
|
|
|
POWER |
COUNTER |
ARMORED HANDSET |
|
|
STATION |
|
|
|
|
|
MODEL |
|
|
|
1520 |
|
MODEL 1500 |
|
|
|
|
HEADSET |
|
POWER |
AUDIO HUB |
|
MODEL 1509 |
HEADSET
Audio Authority® Series 1500 Installer’s Reference Guide 3
2x4 Audio/Video Installation
The Audio/Video Hub configurations allow from one to as many as eight Counter Stations to serve up to 16 Lane Stations. These configurations (1510, 1511, 1512 and 1513) may be audio-only or audio/video. Run a length of Cat 5 cable from each Counter Station to the Hub. Run a length of Cat 5 cable from the Hub to each Lane Station. The total cable length from Counter Station to Lane Station can be up to 1,000 feet. See “Installing Components” for detailed instructions.
|
|
|
POWER |
|
|
|
MIC |
CUSTOMER |
|
|
|
VIDEO ADD-ON |
||
|
|
|
||
|
|
SPEAKER |
LANE STATION |
|
|
|
CALL BUTTON |
LOCATED IN |
|
|
|
DRIVE UP UNIT |
||
|
|
|
||
|
|
TRAFFIC SENSING |
|
|
|
REMOTE CTRL RELAY |
|
||
POWER |
ARMORED HANDSET |
MODEL 1523 |
||
|
||||
|
|
|
MODEL |
|
|
|
|
1520 |
|
|
|
|
EXISTING |
|
AUDIO/VIDEO |
|
|
CAMERA |
|
COUNTER |
HEADSET |
AUDIO/VIDEO HUB |
EXISTING |
|
STATION |
||||
|
TYPICALLY LOCATED IN |
|||
|
|
VIDEO |
||
|
|
TELEPHONE CLOSET OR |
||
|
|
DISPLAY |
||
|
|
UNDER A COUNTER |
||
|
|
|
||
|
|
MODEL 1510 |
|
HEADSET
POWER
SINGLE CAT 5 CABLE
COAX (RG59)
AUDIO OR OTHER WIRE
FROM HUB CAMERA OUTPUTS TO SECURITY VIDEO RECORDER
FROM DVD or PC* AUDIO/VIDEO TO HUB PROGRAM INPUTS
SURVEILLANCE CAMERA OUTPUT TO HUB WIDEANGLE CAMERA INPUT
Illustration: Two Counter Stations serve Four Lane Stations. Counter Stations and Lane Stations may have video capability, or be audio-only. One Lane Station is shown with a Model 1523 Video Add-On; alternatively, any 1520 may be connected to existing camera and video display.
If desired, any 1520 could be replaced by a 1522 Customer Video Station, which has all the capability and connections of a 1520 plus a camera, video display and call button mounted in one enclosure.
* PC video output signals may need to be modified for viewing on intercom video displays. Call Audio Authority for details.
4 Audio Authority® Series 1500 Installer’s Reference Guide
Installing a 1509 Hub
1.Position and install the Hub under the counter or in a secure indoor location such as a telephone closet. Ground the hub to a nearby electrical device cover using the green grounding wire attached to the hub.
2.Run a length of Cat 5 cable from each counter and lane station to the hub. Observe the wiring guide on page 2, and use a cable tester to verify the terminations.
3.Connect audio source to Program Audio jacks if desired, and adjust volume level during system testing.
Illustration: Shown is Model 1509 Audio Intercom Hub. Minimum connections for Audio/ Video Hubs are shown. For more information on Memory and Diagnostics functionality, see page 9.
LEVEL |
CAT 5 CABLE TO |
|
COUNTER STATION #1 |
||
|
COUNTER
STATION 1
PROGRAM AUDIO
|
COUNTER |
|
|
STATION 2 |
CAT 5 CABLE TO |
|
|
|
|
LANE |
LANE STATION #1 |
|
|
|
|
STATION 1 |
|
|
LANE |
|
|
STATION 2 |
|
|
LANE |
|
|
STATION 3 |
|
|
LANE |
|
|
STATION 4 |
|
|
|
1 AMP POWER SUPPLY |
|
12 VOLT |
(MODEL 571-013) |
|
|
|
|
DC POWER |
|
MEMORY |
DIAGNOSTICS |
GROUND WIRE TO ELECTRICAL |
|
|
|
|
|
DEVICE COVER |
Installing a 1510 Hub (1511, 1512, 1513 are similar)
1.Position and install the Hub under the counter or in a secure indoor location such as a telephone closet. Ground the hub to a nearby electrical device cover using the green grounding wire attached to the hub.
2.If the installation requires additional capacity, install a Counter Card or Lane Card(s) as needed (see page 11).
3.Run a length of Cat 5 cable from each counter and lane station to the hub. Observe the wiring guide on page 2, and use a cable tester to verify the terminations.
4.Connect other equipment as needed (see page 11).
FOUR-UNIT COUNTER STATION
CARD (MODEL 1515)
CAT 5 CABLE TO COUNTER STATION #1
FOUR-UNIT LANE STATION
CARD (MODEL 1516)
CAT 5 CABLE TO LANE STATION #1
GROUND WIRE
SYSTEM CARD (MODEL 1517)
SEE PAGE 10 FOR INSTRUCTIONS
1 AMP POWER SUPPLY (MODEL 571-013)
POWER CONNECTION
Illustration: Model 1510, the minimum capacity AV Hub configuration. Minimum connections for Audio/Video Hubs are shown. For more configurations, system card functions, and other connections, see page 11.