WaveDynamics™ Class D power amplifiers
The SMA & SMQ series are Class D Power Amplifiers featuring WaveDynamics™ audio processing technology.
They come in different output configurations with two or four channels and are available in output powers of 350
Watt, 500 Watt and 750 Watt. Their great flexibility and different configurations make it the solution for nearly every
system, no matter if it's a fixed installation or a mobile application.
Speaker
Presets
7 Band
EQ
Digital
Audio Filters
Time
Alignment
WaveDynamics™
A complete library of AUDAC loudspeaker and set solution presets is available for your
projects, making it easy as picking the right file, loading it & play! Besides the optimal acoustic
configurations, this library also includes the loudspeaker performance parameters providing
a bulletproof protection for them.
The 7-band fully parametric equalizer with adjustable frequency and Q factor and Butterworth,
Bessel and Linkwitz-Riley filters with selectable roll-off allow you to create custom
configurations, tweak your setup to the finest detail and adapt to your rooms acoustics. A
delay function allows time alignment of different speakers in your installation.
Configurations also allow you too bridge the outputs, doubling the output power of stereo
channels to one mono channel or make a single three-channel amplifier driving a complete
setup composed of stereo mid/high frequency speakers and a bass cabinet.
Controllability
The operation and configuration of the device can be done in multiple ways. The most
obvious way is by using the front panel controls, featuring a rotary selection dial and channel
selection buttons with a clear and intuitive user inferface on the 2.5" graphical LCD Display.
Total system configurations for pre-defined set solutions can be loaded into the amplifier
using the USB port.
Dynamic
Integration of the audio system into home and industrial automation systems is made easy
through the RS-232 connection & control port whereby functions such as input switching,
volume adjustment, ... can be controlled.
5
7 Band
EQ
Speaker
Protection
Dynamic
Bass
Speaker
Presets
Energy
Efciency
Digital
Audio Filters
7 Band
EQ
Time
AlignmentLockable
Speaker
Protection
Dynamic
Bass
Speaker
Presets
Energy
Efciency
Limiter
Digital
Audio Filters
Protection
Dynamic
Bass
Speaker
Presets
Energy
Efciency
Speaker
Protection
Dynamic
Bass
Speaker
Presets
Energy
Efciency
Flexibility
Every system comes with different requirements and every customer has his own preferences.
Because of this, the structure is made as flexible as possible.
Input Matrix
Speaker
This is achieved by an input selection matrix. Each of the input connections can be patched to
any amplifier channel and contains software controllable gain. The different implementations of
the in- and output connectors allow the easiest way of connection for every application, while
allowing signal link through to other amplifiers.
Protection
Optimal protection is not only required for the listeners satisfaction, but can also be important for
complying to the imposed regulations and guaranteeing the lifetime of the equipment. Because
of this, protection precautions are implemented in different ways.
Firstly, user access is made possible on different levels. The device can be blocked or accessed
in user or administrator level. Different levels allow different configuration and control functions,
giving limited (Eg: only volume) control access to standard users and full configuration control
to administrators. User restriction can be enabled & disabled and is given through password
and / or USB-key.
Secondly, equipment protection is implemented by an output limiter which monitors the
output power of every channel and will intervene when the output exceeds a certain level. The
corresponding level can be software configured and is indicated in Watts. When the output
limiter is configured at the maximum power of the loudspeaker, you can rest assured that the
speakers won't be blown during your absence.
Limiter
Energy
Efciency
Lastly, the maximum volume for every channel can be set indepentently. This prevents users
(having volume access) going over the limit. This can help you to keep the system compliant
with imposed regulations and maintain the good relationship with the neighbors.
Efficiency
The switching mode power supply and Class D Amplifier technology in combination with the
auto-standby mode for each separate amplifier channel brings an end to the era of the powerhungry amplifiers. In addition, these features also result in a lightweight amplifier which benefits
the customer when used in mobile applications.
CHANNEL 4
CHANNEL 3
CHANNEL 2
CHANNEL 1
Input 1
Input 2
Input 3
Input 4
ANALOGUE
GAIN
INPUT SELECT
OFF
ADC
ADC
ADC
ADC
Digital
Audio Filters
7 Band
Time
Alignment
Speaker
Protection
Limiter
Dynamic
Bass
Speaker
EQ
Presets
DSP
DAC
VU READ
RS232
SMA750
Prot
FUNCTION
AUDAC
Clip
-20dB
Sig
ON
POWER
CH1 CH2
Front
USB
ADC
CPU
ADC
TEMP
Level
AMP
6
7
Precautions
READ FOLLOWING INSTRUCTIONS FOR YOUR OWN SAFETY
ALWAYS KEEP THESE INSTRUCTIONS. NEVER THROW THEM AWAY
ALWAYS HANDLE THIS UNIT WITH CARE
HEED ALL WARNINGS
FOLLOW ALL INSTRUCTIONS
NEVER EXPOSE THIS EQUIPMENT TO RAIN, MOISTURE, ANY DRIPPING OR SPLASHING
LIQUID. AND NEVER PLACE AN OBJECT FILLED WITH LIQUID ON TOP OF THIS DEVICE.
DO NOT PLACE THIS UNIT IN AN ENCLOSED ENVIRONMENT SUCH AS A BOOKSHELF
OR CLOSET. ENSURE THERE IS ADEQUATE VENTILATION TO COOL THE UNIT. DO NOT
BLOCK THE VENTILATION OPENINGS.
DO NOT STICK ANY OBJECTS THROUGH THE VENTILATION OPENINGS.
DO NOT INSTALL THIS UNIT NEAR ANY HEAT SOURCES SUCH AS RADIATORS OR
OTHER APPARATUS THAT PRODUCE HEAT
DO NOT PLACE THIS UNIT IN ENVIRONMENTS WHICH CONTAIN HIGH LEVELS OF DUST,
HEAT, MOISTURE OR VIBRATION
THIS UNIT IS DEVELOPED FOR INDOOR USE ONLY. DO NOT USE IT OUTDOORS
PLACE THE UNIT ON A STABLE BASE OR MOUNT IT IN A STABLE RACK
ONLY USE ATTACHMENTS & ACCESSORIES SPECIFIED BY THE MANUFACTURER
UNPLUG THIS APPARATUS DURING LIGHTNING STORMS OR WHEN UNUSED FOR LONG
PERIODS OF TIME
ONLY CONNECT THIS UNIT TO A MAINS SOCKET OUTLET WITH PROTECTIVE
EARTHING CONNECTION
CAUTION - SERVICING
This product contains no user serviceable parts. Refer all servicing to
qualified service personnel. Do not perform any servicing (unless you
are qualified to)
EC DECLARATION OF CONFORMITY
This product conforms to all the essential requirements and further
relevant specifications described in following directives: 2004/108/EC
(EMC) and 2006/95/EC (LVD)
8
WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT (WEEE)
The WEEE marking indicates that this product should not be disposed
with regular houshold waste at the end of its life cycle. This regulation
is created to prevent any possible harm to the environment or human
health.
This product is developed and manufactured with high quality materials
and components which can be recycled and/or reused. Please
dispose this product at your local collection point or recycling centre
for electrical and electronic waste. This will make sure that it will be
recycled on an environmentally friendly manner, and will help to protect
the environment in which we all live.
CAUTION
The symbols shown are internationally recognized symbols that warn about potentional
hazards of electrical products. The lightning flash with arrowpoint in an equilateral
triangle means that the unit contains dangerous voltages. The exclamation point in
an equilateral triangle indicates that it is necessary for the user to refer to the users
manual.
These symbols warn that there are no user serviceable parts inside the unit. Do not
open the unit. Do not attempt to service the unit yourself. Refer all servicing to qualified
personnel. Opening the chassis for any reason will void the manufacturer’s warranty. Do
not get the unit wet. If liquid is spilled on the unit, shut it off immediately and take it to a
dealer for service. Disconnect the unit during storms to prevent damage.
9
Chapter 1
Pin connections and connectors
CONNECTION STANDARDS
The in- and output connections for AUDAC audio equipment are performed corresponding
to international wiring standards for professional audio equipment.
XLR:
For balanced signal input connections
Pin 1: Ground
Pin 2: Signal +
Pin 3: Signal -
3-Pin Terminal Block:
For balanced signal input & link output connections.
Settings19200 Baud
8 Bit
1 Stop bit
No parity
No Handshaking
RS232
The complete command set to control the SMA/SMQ amplifiers through RS-232 is available
in the commands user manual which is freely downloadable on www.audac.eu