n Applications
Load type |
Maximum load |
Examples |
||
|
|
|
|
|
Resistive |
|
• |
incandescent lights |
|
30 A |
• |
halogen lights |
||
load |
||||
|
• |
block heater |
||
|
|
|||
|
|
|
|
|
|
|
• |
fluorescent lights |
|
Inductive |
10 A |
• |
compact fluorescent lights (CFL) |
|
load |
• |
sodium lamps |
||
|
||||
|
|
• |
electronic ballasts |
|
|
|
|
|
|
Motor |
1.5 hp @ 120 VAC |
• |
pool filter pumps |
|
2.0 hp @ 240 VAC |
• |
fans |
||
|
||||
|
|
|
|
o Installation
Line voltage selector switch
|
Power supply |
Motor |
Single-pole switch |
(120/208/ |
|
240 VAC) |
|
|
(for 3-way installation) |
|
|
|
|
|
|
|
Lighting |
n Cut power at the circuit breaker to avoid electric shock. o Perform the connections as shown on the wiring diagram.
NOTE: For a 3-way installation, connect a standard single-pole switch to the 3-way terminals of the timer as shown on the wiring diagram.
p Select the proper operating voltage. q Apply power at the circuit breaker.
TI040
Installation and User Guide
Industrial Indoor / Outdoor Timer
p Power-On
Mode display On/Off display
• Briefly press the button to turn the load On or Off.
• Press the button for 3 seconds to switch between Automatic mode and Manual mode.
Program number
At power-on, 0:00 will flash. Otherwise, press reset using a paper clip. If the display is blank, verify the power supply.
q Setting the Clock
NOTE: The switch displays the time in 24-hour format by default or following a reset.
nTo change to 12-hour format (or vice versa), proceed as follows:
a)Press the MODE button to ensure the MAN or AUTO indicator is displayed.
b)Press the MIN and HOUR buttons simultaneously and briefly (0:00 display = 24-hour, 12:00 display = 12-hour).
oSet the time using the HOUR and MIN buttons. If you have selected the 12-hour format, ensure that PM appears on the screen when an afternoon time is displayed.
p Set the day by using the DAY button.
q Press the MODE button to return to normal operation.
r Selecting the Operating Mode
The programmable switch has 2 operating modes: manual (MAN) and automatic (AUTO). To switch mode, press the MODE button for 3 seconds.
Manual Mode
In Manual mode, the timer operates like a regular switch. Briefly press the MODE button to activate or deactivate the load. (If you have connected a remote switch to the timer for a 3-way installation, the switch can also be used to activate or deactivate the load.) The mode indicator (MAN) and the state (ON or OFF) are displayed.
Automatic Mode
In Automatic mode, the timer follows the programmed schedule (see section 6). The mode indicator (AUTO), the state (ON or OFF) and the current program number are displayed.
To temporarily override the programmed schedule, press the MODE button or use the 3-way installation switch (if connected). The new