ATX Maxnet II QMP 1000 Installation & Operation Manual

QMP1000 Forward RF Amplier
Installation & Operation Manual
CCAP
Com
pliant
1.2 GHz
Although every effort has been taken to ensure the accuracy of this document it may be necessary, without notice, to make amendments or correct omissions.
Specications subject to change without notice.
MAXNET® II is a registered trademark of ATX in the United States and/or other countries. Products or features contained herein may be covered by one or more U.S. or foreign patents. Other non-ATX product and company names in this manual are the property of their respective companies.
TABLE OF CONTENTS
Page
1. PRODUCT DESCRIPTION ........................................................................................................................ 1-1
1.1. Functional Diagrams.......................................................................................................................... 1-2
1.2. Technical Specications .................................................................................................................... 1-3
2. INSTALLATION .........................................................................................................................................2-1
2.1. Product Inspection ............................................................................................................................. 2-1
2.2. Module Installation into the Active MAXNET® II Chassis ................................................................... 2-1
2.3. RF Connections ................................................................................................................................. 2-2
2.4. Amplier Set-Up ................................................................................................................................ 2-2
3. STATUS MONITORING .............................................................................................................................3-1
3.1. Chassis Interface Options ................................................................................................................. 3-1
3.2. SCTE HMS MIB Software Denition of Module................................................................................. 3-1
3.3. Web Interface .................................................................................................................................... 3-1
3.4. Updating Active Chassis Firmware .................................................................................................... 3-2
3.5. Factory Reset .................................................................................................................................... 3-2
4. STATUS MONITORING FEATURES ......................................................................................................... 4-1
4.1. SNMP Parameters .............................................................................................................................4-1
4.2. SNMP MIBs Required for QMP1000 ................................................................................................. 4-2
5. MAINTENANCE & TROUBLESHOOTING ................................................................................................ 5-1
5.1. Maintenance ...................................................................................................................................... 5-1
5.2. Troubleshooting ................................................................................................................................. 5-1
6. SERVICE & SUPPORT .............................................................................................................................. 6-1
6.1. Contact ATX Networks ....................................................................................................................... 6-1
6.2. Warranty Information ......................................................................................................................... 6-1
6.3. Safety ................................................................................................................................................ 6-1
MAXNET® II – QMP1000 Forward RF Amplier – Installation & Operation Manual i
Index of Figures and Tables
Figures
#1 Single Stage Forward RF Amplier Functional Diagram .............................1-2
#2 Dual Stage Forward RF Amplier Functional Diagram ................................1-2
#3 Front & Rear Panel Pictures ........................................................................2-1
#4 Front Panel Plug-ins ....................................................................................2-3
#5 Web Interface Parameter Page (example) ..................................................3-1
Tables
#1 Ordering Information ....................................................................................1-1
#2 Technical Specications ..............................................................................1-3
#3 LED Status Indications ................................................................................2-2
#4 Plug-in PAD Specications ..........................................................................2-3
#5 Plug-in 1 GHz EQ Specications .................................................................2-3
#6 Plug-in 1.218 EQ Specications ..................................................................2-3
#7 Plug-in PAD/EQ Ordering Information .........................................................2-4
#8 Common Module Parameters ......................................................................4-1
#9 QMP1000 SNMP Parameters ......................................................................4-1
#10 General SCTE HMS MIBs Required ...........................................................4-2
#11 QMP1000 SCTE HMS MIBs Required ........................................................4-2
ii MAXNET® II – QMP1000 Forward RF Amplier – Installation & Operation Manual
CHAPTER 1: PRODUCT DESCRIPTION
Part Number Description
PRODUCT DESCRIPTION
1. Product Description
The QMP1000 MAXNET II modules are Forward RF Ampliers, which offer various gains that are determined at the time of ordering. The lower gain ampliers (17 dB and 21 dB gain) operate in a single stage manner as shown in the functional diagram – Figure #1, Page 6. The higher gain ampliers (28 dB, 31 dB and 34 dB gain) operate in a dual stage process as shown in the functional diagram – Figure #2, Page 6. The QMP1000 ampliers are dual-width modules, taking
up two slots in the Active MAXNET II Chassis and they are powered through a hot-swapping backplane. An appropriate MAXNET II Power Supply in the Active MAXNET II Chassis powers these modules. The QMP1000 modules feature the standard MAXNET II functionality including high-density packaging through the use of MCX coaxial cable connectors (F
connectors are available as option) in conjunction with Mini RG-59 Type coaxial cable. Also featured are: front access
alarm LED indicator, -20 dB test points and the capability of module status monitoring through SNMP based Managers. The MAXNET II SNMP interface is HMS compliant.
Please refer to the web page for up-to-date specications – www.atxnetworks.com
QMP1000-17GP 1000 MHz, 17 dB GaAs Single Stage, MCX Connectors
QMP1000-21GP 1000 MHz, 21 dB GaAs Single Stage, MCX Connectors
QMP1000-28GP 1000 MHz, 28 dB GaAs Dual Stage, MCX Connectors
QMP1000-31GP 1000 MHz, 31 dB GaAs Dual Stage, MCX Connectors
QMP1000-34GP 1000 MHz, 34 dB GaAs Dual Stage, MCX Connectors
QMP1000-17GPF 1000 MHz, 17 dB GaAs Single Stage, F Connectors
QMP1000-21GPF 1000 MHz, 21 dB GaAs Single
QMP1000-28GPF 1000 MHz, 28 dB GaAs Dual Stage, F Connectors
QMP1000-31GPF 1000 MHz, 31 dB GaAs Dual Stage, F Connectors
QMP1000-34GPF 1000 MHz, 34 dB GaAs Dual Stage, F Connectors
Stage, F Connectors
Table #1: Ordering Information
MAXNET® II – QMP1000 Forward RF Amplier – Installation & Operation Manual 1-1
CHAPTER 1: PRODUCT DESCRIPTION
1.1. Functional Diagrams
Single Stage Forward Amplifier
RF INPUT
-20 dB INPUT TEST POINT
PWR
+24 VDC
FAN
ACTIVE FUSE, POWER & FAN
CTRL
Figure #1: Single Stage Forward RF Amplier Functional Diagram
Dual Stage Forward Amplifier
RF INPUT
-20 dB INPUT
TEST POINT
PWR
PAD EQ
PAD EQ
PAD EQPAD EQ
RF
DETECTOR
MONITOR & CONTROL
RF
DETECTOR
RF OUTPUT
-20 dB OUTPUT TEST POINT
CHASSIS COMM.
ALARM
RF OUTPUT
-20 dB OUTPUT TEST POINT
+24 VDC
FAN
ACTIVE FUSE, POWER & FAN
CTRL
Figure #2: Dual Stage Forward RF Amplier Functional Diagram
MONITOR & CONTROL
CHASSIS COMM.
ALARM
1-2 MAXNET® II – QMP1000 Forward RF Amplier – Installation & Operation Manual
1.2. Technical Specications
Table #2: Technical Specications
MAXNET® II – QMP1000 Forward RF Amplier – Installation & Operation Manual 1-3
Loading...
+ 15 hidden pages