Attwood Tsunami 4606, Tsunami 4612, Tsunami 4608, Tsunami 69390, Tsunami 4613 User Manual

®
3
Figure 1
Thru-Hull Connector Hose & Clamp
Tsunami Bilge Pump
4606, 4608, 4612, 4613 Series
Installation Instructions
SAVE THESE INSTRUCTIONS
Form Number 69390 Rev. A 10-03
WARNING
DO NOT use pump to remove gasoline, oil or other flammable liquids. Always use the fuse amperage rating specified for your pump model. Failure to do so could result in serious personal injury or fire hazards.
Attwood bilge pumps are designed to exhaust STANDING WATER ONLY. They are not intended to prevent rapid accumulation of on-board water due to rough weather, hull damage, and/or other unsafe navigational conditions.
Refer to Specification Chart to be sure you have selected the proper pump:
12-Volt Models
Part Outlet Head Head Head Head Head Head Num./ Hose Motor Amp GPH/ GPH/ GPH/ LPH/ LPH/ (ft.@13.6v/ Series I.D. Cart. Fuse amps amps amps amps amps kPa@12v)
4606/600 3/4" 4620 2.5A 500/1.5 400/ 1.5 250/1.5 1705/1.3 1250/1.3 8'/27 4608/800 3/4" 4622 4A 800/3.0 660/3.0 510/3.0 2840/2.5 2274/2.5 14'/33 4612/1200 1-1/8" 4624 5A 1200/3.5 900/3.5 700/3.5 4169/3.0 3000/3.0 11' 7"/28
24-Volt Models
Part Head Head Head Head Head Head Num. Amp GPH/ GPH/ GPH/ LPH/ LPH/ (ft.@24v/ Series Fuse amps amps amps amps amps kPa@24v)
4609/800 3/4" 4623 2A 800/1.3 660/1.3 500/1.3 2842/1.1 2160/1.1 14'/31 4613/1200 1-1/8" 4625 2A 1200/1.5 900/1.5 725/1.5 4100/1.3 3100/1.3 11'/28
MATERIALS REQUIRED
• Three #8 stainless fasteners, suitable length for mounting surface
• Cordless drill and 1/8" (3mm) bit
• Hose clamps (Attwood # 9185, 2 per connection)
• Mounting pad: marine plywood, fiberglass cloth and resin
• Manual (# 7615A) or automatic float switch (#4201 or 4202)
• Fuel-resistant, reinforced smooth bore outlet hose
INSTALLATION LOCATION
1. Position pump in the lowest accessible part of the bilge. On sailboats, location should be centered over keel. (Figure 1)
ABYC Specifications ISO Specifications
@13.6 VDC @12 VDC
(GPH = Gal. Per Hour) (LPH = Liters Per Hour)
0 ft. 3.3 ft 6.7 ft 0kPa 10kPa Max
ABYC Specifications ISO Specifications
@24.0 VDC @24.0 VDC
(GPH = Gal. Per Hour) (LPH = Liters Per Hour)
0 ft. 3.3 ft 6.7 ft 0kPa 10kPa Max
Base Strainer
Suitable Mounting Pad
2. Do not mount pump directly to hull. Attach base strainer to a marine plywood mounting pad that is fiberglassed to the hull.
HOSE CONNECTION INSTRUCTIONS IMPORTANT: To prevent airlock, hose must rise continually upward
to the thru-hull connector with no dips or sharp bends. Support hose if necessary.
1. Orient pump outlet for a direct, unobstructed hose path.
2. Secure all connections with hose clamps.
3. If no thru-hull connector exists, install at 12" min. (25mm) above water line. Apply marine sealant around thru-hull flanges on interior and exterior of hull.
PUMP MOUNTING INSTRUCTIONS
1. To access mounting holes, remove base strainer. Hold housing with one hand, depress locking tab with other. Twist counter-clockwise and remove pump housing from base. It is not necessary to remove motor cartridge for installation. (Figure 2)
Figure 2
Lock
Unlock
Pump Housing
(3) #8 Fasteners
Base Strainer
1/8" Pilot Holes
2. Use base as template to mark 3 mounting holes in mounting pad.
CAUTION: Do not drill through hull. Before drilling be sure mounted pump will be correctly positioned with pump nozzle pointing toward thru-hull connector. (Figure 1)
3. Remove base. Drill three 1/8" (3mm) pilot holes at marked locations.
4. Replace base. Attach with #8 stainless steel fasteners.
5. Re-attach pump to base. Insert into base, twist clockwise until tab snaps in and prevents turning. (Figure 2)
WIRING INSTRUCTIONS
Make all wire connections above the highest water level. Use marine grade wire connectors only. Waterproof all connections with suitable materials. (Figure 3)
NOTE: Failure to make waterproof connections and fuse pump properly will void the product warranty.
Unlock
Lock
Motor Cartridge Replacement
Press Tab To Unlock
12" min. Above
Water Line
Hose MUST Rise
Upward with NO DIP
Motor Cartridge Ta b
Figure 3
Fuse Holder
2-Terminal On/Off Switch
Brown Wire
72" (183cm) Max. Length From (+) Terminal to Fuse
Black Wire (neg) (pos)
12 or 24 Volt DC
(Power Source)
1. Connect positive lead (brown) to switch. For automatic operation, use Attwood Automatic Float Switch (#4201 or 4202). Connect negative lead (black) to ground.
2. Install fuse holder within 72" (183 cm) of the positive (+) battery terminal. Use standard automotive (SAE J554) glass tube type electrical fuse.
3. To test system, feed water into the pump. If flow appears low, be sure wires have been connected properly: Brown-to-positive (switch), and black-to-negative. Reversed wiring reduces performance and can cause pump failure.
MAINTENANCE AND TROUBLESHOOTING
Disconnect power to the pump. Regularly inspect and clean to be sure that debris is not blocking the strainer or impeller.
If pump runs but does not pump water:
1. Check for airlock. Be sure that outlet hose runs upward to the thru-hull connector, with no dips. (Figure 1)
2. Remove pump housing from base. Remove debris from chamber and impeller. Be sure impeller is firmly attached to shaft and is not cracked or broken. (Figure 2)
If pump does not run:
1. Check fuse. Be sure electrical connections and fuse are waterproof and haven’t loosened. (Figure 3)
To replace motor cartridge:
1. Hold pump housing, depress motor cartridge tab and twist cartridge counter-clockwise to remove (Figure 2).
2. Check motor cartridge fit: See specification chart for replacement motor cartridge number. Motor must match housing color: 500 Series = RED, 800 = BLUE, 1200 = GRAY.
3. To reinstall cartridge: Coat O-ring with vegetable oil (petroleum-based oils will cause deterioration).
4. Insert cartridge into housing. Twist clockwise until you hear tab snap up into slot. (Figure 2)
ATTWOOD BILGE PUMPS LIMITED WARRANTY
This Attwood Bilge Pump carries a three (3) year warranty. See product catalog or
www.attwoodmarine.com for details.