APF-15TU/APF-15TUC
UL Listed 15 Watt Flange Mounting Voice Control Loudspeakers
Features
• ULListedforFireProtectiveSignallingSystems
• High-Efficiency,15WattCompressionDriver
• BuiltInVari-Tap® Transformer for Easy Impedance Selection
• CompatiblewithRoundorSquareDecorativeBaffles
• FlangeandRecessedMountingProvisionsforUseonInterior/Exterior
Walls and Ceilings
• VandalandEnvironment-ResistantMetalConstructionforOutdooror
Indoor Use
• RecommendedforHighIntelligibilityPaging,Intercommunication,
and Signaling
APF-15TU Series
Specifications (UL Rating)
Models APF-15TU, APF-15TUC
Power Rating 15 Watts Continuous
Frequency Response 400 - 4000 Hz
Sensitivity 102dB at 15 Watts, 10ft
(3dB Increment UL Rating)
Specifications (Anechoic Measurements)
Frequency Response 600 - 14,000 Hz (Nominal)
700 Hz - 5500 Hz (±5dB)
Sensitivity 120dB at 15 Watts (Peak)
114dB at 15 Watts/1 Meter (Avg) 700 - 5500 Hz
104dB at 1 Watt/1 Meter (Avg) 700 - 5500 Hz
Dispersion Angle 95˚ (-6dB, 2000 Hz Octave Band)
Weight APF-15TU: 2.5 lbs (1.1kgs)
APF-15TUC: 2.75 lbs (1.2kgs)
Finish Grey Baked Epoxy
Dimensions Dia 5
Temperature Range -40˚C - 70˚C
Architect and Engineer Specifications
Loudspeaker shall be Atlas Sound Model ______ (APF-15TU, APF-15TUC)
or approved equal. Unit shall be double re-entrant type with compression
driver mounted within waterproof housing. Audio power capability shall
be 15 watts full range and shall be able to operate within an ambient
temperature environment ranging from 70˚ C (158˚ F) to -40˚ C (-40˚ F).
The unit shall meet UL frequency range requirements of 400 Hz - 4 kHz
and shall have a sound pressure level of 102dB at 15 Watts, 10 ft. (3dB
increment UL Rating). Voice coil impedance shall be 8 Ohms with sound
dispersion angle of 95˚. Unit shall have impedance selection via 7-position
switch of 5000, 2500, 1300, 666, 333, 89 and 45 Ohms. Power taps shall
be available at 1, 2, 3.8, 7.5, 15 Watts for 70V line and .48, .94, 1.8, 7.5,
15 watts for 25V line. Provision for flange or recessed mounting shall
be by means of eight, 3⁄16" evenly spaced holes on a 61⁄8" diameter circle.
Mounting kit Model MK-2 or FAMT-6 (not furnished) shall be used to
mount loudspeaker to 8" diameter baffles. A cork-rubber gasket which
provides a weather-tight seal between speaker flange and mounting
surface shall be provided. Wiring terminals for amplifier output shall be
fully enclosed and vandal-resistant adapter cover shall provide connection
facilities for cable or conduit. Dimensions shall be
©2010 Atlas Sound L.P. All rights reserved. Atlas Sound is a trademark of Atlas Sound L.P. All other trademarks are the property of their respective owners. ATS003856 RevA 5/10
Dia 55⁄8" x D 53⁄16" x Dia Flange 615⁄16".
5
⁄8" x D 53⁄16" x Dia Flange 615⁄16"
Applications
Communicate voice and electronic signals clearly in industrial,
commercial, recreational, transportation and service facilities with Atlas
Sound’s UL-Listed APF Series loudspeakers. These environment-resistant
units are engineered to meet life safety and general communication
requirements and are ideal for indoor or outdoor applications where highintelligibility paging or intercommunication are necessary.
Description
APF Series voice control loudspeakers are equipped with a compression
driver to provide up to 15 Watts of continuous power handling, superior
intelligibility and audio conversion efficiency for maximum sound
projection and penetration.
APF Series loudspeakers may be flush mounted or recessed directly
into interior/exterior walls or ceilings. Recessed installation may be
accomplished by mounting loudspeakers into a 51⁄2" deep opening or
recessed enclosure. Units will facilitate Atlas Sound L20 Series grilles,
enclosures and mounting rings (refer to ATS003855). Accessory mounting
kits Model MK-2 or FAMT-6 can be used to mount loudspeakers into 8"
diameter baffles.
Models include a built-in 25/70.7V Vari-Tap® transformer featuring a
screw-driver adjustable, 7-position watt/impedance selection switch.
Magnet assembly is equipped with self-aligning field replaceable
diaphragm. Wiring terminals are protected with a vandal-resistant adapter
cover for control equipment utilizing cable or conduit.
A built-in, 5 mfd capacitor is provided on Model APF-15TUC for line
supervision. Model APF-15TU is not equipped with a capacitor. All units
are finished in grey baked epoxy.
All models meet or exceed UL Standard 1480 for Fire Protective
Loudspeakers and are capable of operating within an ambient
temperature range of 70˚C (158˚F) to -40˚C (-40˚F). The all-metal,
environment-resistant construction and re-entrant acoustic path assure
protection against water, humidity, vermin, physical abuse, and corrosion.
Models are also California State Fire Marshal Listed. Models with special
modifications to meet other safety authorities are available. Contact
factory.
Accessories
BX-3A Vandal resistant cover plate for armored cable
and conduit connection. Constructed of cast
aluminum.
1601 JACK MCKAY BLVD. ENNIS, TEXAS 75119 U.S.A.
TELEPHONE: (800) 876-3333
FAX (800) 765-3435
AtlasSound.com
1/2
Fundamental
Polars Are Normalized To Zero On Axis
2nd Harmonic
Frequency
Lp Q Di Beamwidth
(Hz)
1000 94.73 3.37 5.27 160
2000 91.37 7.30 8.63 95
4000 89.23 11.95 10.77 90
8000 83.54 44.29 16.46 25
15 watts @1 meter
(Degrees)
MAGNITUDE (dB)
3rd Harmonic
Frequency (Hz)
To Conform With UL Requirements, Wires Must be
Connected as Shown in Wiring Diagram
From
Amplifier
CAUTION:
• Do Not Loop Wires Under Screw Terminals. Break Wire Run to Provide
Supervision of Connections.
• Maximum Wire Size is 18-GA.
To Next
Speaker
or End
of Line
Resistor
APF-15TU(C) Wiring Diagram
MAGNITUDE (dB)
1 watt @ 1 meter
Frequency (Hz)
APF-15TU(C) Frequency Response APF-15TU(C) (Harmonic Distortion - 1.5 watts @ 1 meter)
CAUTION: Amplifier output line connection is made
to the screw terminals which are designed with wire
retainers for insured reliability. Input terminals are
numbered (#1 and #2) to maintain system phasing
(#2 is the positive terminal). The wide and narrow slots
adjacent to #1 and #2 are used for cable strain relief.
Atlas Sound products are designed and tested in our well-equipped research laboratory which contains a fully anechoic chamber, complete
©2010 Atlas Sound L.P. All rights reserved. Atlas Sound is a trademark of Atlas Sound L.P. All other trademarks are the property of their respective owners. ATS003856 RevA 5/10
1601 JACK MCKAY BLVD. ENNIS, TEXAS 75119 U.S.A.
TELEPHONE: (800) 876-3333
FAX (800) 765-3435
analog Bruel & Kjaer measurement equipment and Techron
Vari-Tap® Selector Switch
®
TEF 20® audio analyzer. Atlas Sound is proud to be a beta site for TEF software.
AP-15TU(C) Vari-Tap® Control Connect Center Xfmr. Power Taps
Switch
Position
Impedance
(Ohms)
Watts
@ 25V
*dB
10ft
Watts
@ 70.7V
*dB
10ft
1 5000 – – 1 93
2 2500 – – 2 96
3 1300 .48 90 3.8 96
4 666 .94 90 7.5 99
5 333 1.8 93 15 102
6 89 7.5 99 X** X**
7 45 15 102 X** X**
* UL 3dB Increment Rating ** Do Not Use
AtlasSound.com