Prior to Operation and Installation
• When the pump is delivered, first perform the following checks.
• Check for any damage to pump and power cable that may have
occurred during the shipment.
• Check the model number to make sure it is the product that was
ordered and verify the voltage and frequency are correct.
Caution
• DO NOT operate this product under any condition other than
those for which it is specified. Failure to observe this precaution can
lead to electrical shock, electrical leakage, fire, water leakage or
other problems.
• The pump is a 100/120 volt 60 Hz pump, please only use with a power
supply voltage within 100-120 volt 60 Hz.
• Never place your hand or any object in or near the inlet opening while
this equipment is operating. If pump inlet is clogged, always turn off
the power supply and wait until the motor is completely stopped before
attempting to remove any clogged material.
• Please make sure that the power plug and the AC outlet receptacle is
protected and away from water or pump discharge hose to prevent
accidental electric shock or short circuit.
• Always operate the pump completely submerged in water.
• Avoid dry operation, which will not only lower performance but can
cause the pump to overheat/malfunction, leading to electrical leakage,
shock or premature failure.
• CAUTION:
THIS PUMP IS TO BE USED IN A CIRCUIT PROTECTED BY A GROUND CIRCUIT INTERRUPTER.
• ATTENTION:
CETTE POMPE DOIT ETRE BRANCHEE A UNE DERIVATION PROTEGEE PAR UN
DISJONCTEUR DIFFERENTIEL.
• CAUTION:
THIS PUMP HAS BEEN EVALUATED FOR USE IN WATER ONLY.
Introduction
Thank you for selecting the Tidal Wave TW1900, TW2400, TW3700,
TW4800, or TW6000 series pumps. Before using this pump please take
a moment to review this manual.
TW1200 TW1900 TW2400 TW3700 TW4800 TW6000
Watts
110 130 175 355 425 495
Discharge Size
1.5” 1.5” 1.5” 1.5” 1.5” 2”
Inlet Size
1.5” 1.5” 1.5” 2” 2” 2”
Shut Off in Feet
16 18 22 24 26 29
G P H A T H E A D H E I G H T
1’
1290 1900 2400 3730 4800 6000
5’
1080 1440 1950 3010 4000 5040
10’
720 900 1390 2230 3140 4050
15’
180 360 825 1425 2228 3000
20’
0 0 220 660 1260 1930
To avoid an accident
do not use the pump
in any way other than
as described in this
manual. Please note
the manufacturer
cannot be responsible
for accidents arising
because the product
was not used as
prescribed. After
reading this manual
keep it as a reference
in case questions
arise during use.
2 3
Performance: TW2 Series
HE IGHT I N FEE T
G ALL ONS P ER HOU R
36’
32’
28’
24’
20’
16’
12’
8’
4’
1000 2000 3000 4000 5000 6000
0
TW1900
TW2400
TW3700
TW6000
TW4800
TW1200