FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT:
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
The device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may cause
undesired operation.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate this equipment.
CE Warning: This is a class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to take adequate
measures.
KCC Statement
유선 제품용 / A 급 기기 ( 업무용 방송 통신 기기 )
이 기기는 업무용 (A 급 ) 전자파적합기기로서 판매자 또는 사용자는 이점을 주의
하시기 바라며 , 가정 외의 지역에서 사용하는 것을 목적으로 합니다 .
RoHS
This product is RoHS compliant.
2
SJ/T 11364-2006
The following contains information that relates to China.
CS261 RS-232 Control Tool
3
CS261 RS-232 Control Tool
RS-232 Operation
Overview
The CS261’s built-in bi-directional RS-232 serial interface allows system
control through a high-end controller or PC. RS-232 serial operations in a
CS261 installation are managed via HyperTerminal sessions on systems that
are running Windows. In order to use this feature to send commands to the
CS261, you must first download and install a HyperTerminal application. For
more detailed instructions and information about each of the commands
provided in this manual, please refer to the original CS261 user manual.
Setup
Install a HyperTerminal application on a computer that is not part of the CS261
setup, which will be connected and used to control the CS261 via RS-232.
HyperTerminal applications can be download from the internet, and many
operating systems are embedded with HyperTerminal applications.
Hardware Connection
Use an RJ-11 to DB-9 serial adapter
connect the computer’s serial port to the Serial port of the CS261, as shown
below:
4
(ATEN model no.: LIN5-04A2-J11G) to
CS261 RS-232 Control Tool
Console Login - HyperTerminal
Once a physical connection from the computer to the CS261 has been made,
you can establish a HyperTerminal session using the instructions below.
1. Open the HyperTerminal application, and configure the port settings for
the appropriate COM port number, then click OK.
Bits per Second: 19200, Data Bits: 8, Parity: None, Stop bits: 1, Flow Control:
None.
2. When configured correctly a login prompt like the one below appears:
5
CS261 RS-232 Control Tool
RS-232 Commands
After you login via HyperTerminal (see Console Login - HyperTerminal,
page 5), you can use the instructions below to send RS-232 commands to
control the CS261 from a remote system.
When the RS-232 link is opened, the CS261 will no longer accept commands
from front panel buttons or most of hotkey functions (excluding hotkey
switching mode, console status and turn off/on the other monitor and audio).
For more detailed instructions and information about each of the RS-232
commands listed below, please refer to the original CS261 user manual.
Verification
After entering a command, a verification message appears at the end of the
command line, as follows:
Response MessageDescription
command OKCommand or parameter is correct.
command incorrectCommand or parameter is incorrect.
6
CS261 RS-232 Control Tool
Switch Operation
The switch port command allows you to switch between computers connected
to the CS261’s ports. Use the Formula - to set Parameters - to create a
Command.
Formula:
Command + Input Command + [Enter]
Parameters:
CommandDescription
swSwitch Operation Command
Input CommandDescription
autoSelect auto mode
pxInput console number manually,
x= 1~2 (Default: 1)
privateSelect private mode.
Privileged user depends on DIP
switch pin 4 setting.
EnterDescription
EnterEnter and send out command
Switch Console Commands
Some available formulas for the Switch Console commands are as follows:
Command + Input Command + [Enter]
To switch to console 2, type the following:
sw p2 [Enter]
To switch to auto mode, type the following:
sw auto [Enter]
Note: 1. Each command string can be separated with a space.
2. The default console selected is 1.
3. The ASCII code for Enter is 0x0D0A.