MULTIFUNCTIONAL TESTGENERATOR FOR TRANSIENTS
(EFT/BURST, SURGE & POWER FAIL) UP TO 7KV
FOR TESTS ACCORDING TO ...
> ANSI/IEEE C62.41
> EN 61000-4-11
> EN 61000-4-12
> EN 61000-4-29
> EN 61000-4-4
> EN 61000-4-5
> EN 61000-4-8
> EN 61000-4-9
> EN 61000-6-1
> EN 61000-6-2
> EN 61543
> IEC 60255-22-5
> IEC 61000-4-11
> IEC 61000-4-12
> IEC 61000-4-29
> IEC 61000-4-4
> IEC 61000-4-5
> IEC 61000-4-8
> IEC 61000-4-9
> IEC 61008-1
> IEC 61009-1
> ...
UCS 500N7 - MOST ENHANCED ULTRA COMPACT TESTER AS PER IEC 61000-4-X AND ANSI/IEEE C62.41
The UCS 500N7 ultra-compact simulator is the most versatile tester to cover transient and power fail requirements according
to international standards (basic and generic standards) and product/ product family standards with voltage capability of
up to 7.0 kV. Apart from the IEC 61000-4-5 standard for surge testing it also complies to ANSI/IEEE C62.41 for surge and
ringwave testing.
The UCS 500N7 not only represents the most economic solution for full-compliant immunity tests and CE Marking but goes
far beyond. Having a built-in CDN for single phase DUTs it can be extended for testing three-phase DUTs by means of an
automatically controlled external coupling network up to 100A.
EM TEST supplies a large range of accessories for the various applications.
ALL IN ONE AND MORE - ALL WHAT YOU NEED FOR TESTS
UP TO 7KV
The UCS 500N7 includes everything necessary to conduct
fully compliant tests at levels that go far beyond common
test requirements.
Surge can be test up to 7.0kV either according to IEC
61000-4-5 or ANSI/IEEE C62.41. The UCS 500N7 offers an
integrated Ringwave module (optional) as per ANSI/IEEE
C62.41 and IEC 61000-4-12 for ringwave tests on mains
supply lines.
The UCS 500N7 can be operated manually from the front
panel or by remote via the built-in USB or GPIB interface.
Fail inputs allow to control an ongoing test sequence
based on the status of the DUT. Monitoring outputs (BNC)
are offered for easy signal measurement and verification.
Safety features such as interlock and warning lamp
control are available.
Pre-programmed Standard Test routines allow highest
user convenience. Still the UCS 500N7 offers the Quick
Start test routine where parameters can be changed
on-line during the test to evaluate the susceptibility level
of an individual DUT, a most appreciated benefit for tests
at development stage.
SOFTWARE
IEC.CONTROL SOFTWARE FOR CONTROL AND
DOCUMENTATION
Outstanding user convenience, clearly structured
windows and operation features and the EM TEST
standards library along with the flexibility to generate
user specific test sequences very easily are the main
features of iec.control software. The software is
automatically configured according to the connected EM
TEST generators. Extensive reporting capabilities help the
user to create test reports that meet international
requirements.
iec.control is supported by Windows 2000, Windows XP,
Windows Vista and Windows 7. Remote control is
achieved either via USB or GPIB. iec.control supports a
wide range of GPIB cards of National Instruments.
OTHER MODELS
UCS 500N SERIES - COMPACT TESTERS UP TO 7.0KV
The UCS 500N ultra-compact testers for EFT/burst, Surge
and Power Fail are available in two different models; with
voltage capability up to 4.4kV or up to 7.0kV.
OPERATION
EASY TO OPERATE
Front panel menu and function keys enable the user to
program his test routines quickly and accurately. The
cursor allows fast control of all test parameters of the
programmed routine, thus test procedures are simplified
and confidence is generated that every step is carried out
correctly.
AUXILIARY DEVICES
CNI 503 - 3PHASE COUPLING/DECOUPLING NETWORKS
FOR BURST AND SURGE
EM TEST offers a range of fully automatic 3-phase
coupling/decoupling networks for burst and surge to
extend the test capability for three-phase DUTs. The
networks have a rated current of up to 100A.
MV 2616 - MOTORISED VARIAC FOR VOLTAGE VARIATION
A motorised variac is offered as an alternative to the
tapped autotransformers for voltage dips/interruptions
and voltage variation tests as per IEC 61000-4-11. The
motorised variac can also be used for automated
magnetic field tests.
CNV 504N/508N - SURGE COUPLING/DECOUPLING
NETWORKS FOR SIGNAL/DATA LINES
CNV 504N/508N coupling/decoupling networks are
available to perform surge tests on I/O lines, signal/data
lines and telecom lines as per IEC 61000-4-5.
V 4780 - TAPPED VOLTAGE TRANSFORMER FOR VOLTAGE
DIPS AND INTERRUPTIONS
The V 4780 tapped autotransformer is designed to supply
the required voltages as per IEC 61000-4-11 Ed.2:2004 to
perform voltage dips and interruptions.
V 4780S2 - TAPPED VOLTAGE TRANSFORMER FOR
VOLTAGE DIPS AND INTERRUPTIONS
The V 4780S2 tapped autotransformer is designed to
supply the required voltages as per IEC 61000-4-11
Ed.2:2004 to perform voltage dips and interruptions.
Compared to the manually operated V 4780 the V 4780S2
model offers automatic change of taps according to the
selected voltage level.
MS 100N - MAGNETIC FIELD COIL FOR POWER-FREQUENCY
AND PULSED MAGNETIC FIELDS
The MS 100N is a 1sqm magnetic field coil as specified in
IEC/EN 61000-4-8 and IEC/EN 61000-4-9. Its design
allows easy moving of the coil. The field coil is adjustable
in height and allows for 360degr rotation.
To generate power-frequency magnetic fields in the lower
range the current transformer MC 2630 is used while
high-field strength above 100A/m requires the MC 26100
current transformer.
HFK - CAPACITIVE COUPLING CLAMP
The HFK is a fully compliant capacitive coupling clamp as
per specification of IEC 61000-4-4.
ITP - IMMUNITY TEST PROBES
ITP is a tool being used for development test. It consists
of a variety of electrical field probes. The probes allow to
locate weak points within a system or on a PCB. The burst
pulse is used to generate the disturbance signal.
CA EFT KIT - VERIFICATION KIT FOR EFT/BURST PULSES
As per IEC 61000-4-4 Ed.2 the characteristic of the burst
generator needs to be verified with two different loads,
50ohm and 1,000ohm. EM TEST offers a calibration kit
consisting of the two loads and an adapter to verify the
pulses at the DUT output.
DirectVia 50ohm coaxial connector
Coupling modeL, N, PE; all combinations
DUT supplyAC: 300V/16A; 50/60Hz
DC: 300V/10A
CRO trigger5V trigger signal for oscilloscope
TEST ROUTINES
Quick StartOn-line adjustable parameters,
easy-to-use
Standard Test
routines
User Test routinesSynchronous burst release
As per IEC 61000-4-4, Levels 1 - 4
As per EN 61000-6-1, -6-2
Manual Standard Test routine
Random burst release
Change voltage after T
Frequency sweep within one burst
Frequency sweep with constant
number of pulses
Frequency sweep with constant
burst duration
Change polarity after T
POWER FAIL, DIPS & INTERRUPTIONS, VOLTAGE VARIATIONS
POWER FAIL MODULE, PFS/N7
As per EN/IEC 61000-4-11 and
EN 61000-6-1, -6-2
Channel PF1/PF2AC voltage: max. 300V
AC current: max. 16A
Frequency16Hz - 500Hz
Switching time< 5us into a 100ohm resistive load
Inrush current> 500A
ProtectionBoth channels are protected against
DUT terminalsL, N and PE
CRO trigger5V trigger signal for oscilloscope
TEST ROUTINES
Quick StartOn-line adjustable parameters,
easy-to-use
Standard Test
routines
User Test routinesVoltage variation, external variac
50/60Hz magnetic
field
OPTIONS
V4780Tapped autotransformer as per IEC
V4780 S2Tapped autotransformer as per IEC
As per IEC 61000-4-11 for AC
supplies
As per IEC 61000-4-29 for DC
supplies
As per EN 61000-6-1, -6-2
Manual Standard Test routine
control
Change phase angle after n events
Change event duration after n
events
Inverse mode
As per EN/IEC 61000-4-8
Test levels 1, 3, 10 and 30A/m with
external current transformer
MC2630
Test levels 100, 300 and 1,000A/m
with external current transformer
MC26100
61000-4-11 Ed.2
61000-4-11 Ed.2 with automatic
change of tap
MEASUREMENTS
DUT voltageIn the LCD display
DUT currentIn the LCD display
MON VMeasurement of the DUT voltage;
built-in 100:1 divider
MON IMeasurement of the DUT current;
10mV/A; max. 1,000A
MV2616Motorised variac (0 - 250V, 16A)
MS100NMagnetic field coil, 1m x 1m
MC2630Current transformer for magnetic
EM TEST GmbH > Lünener Straße 211 > 59174 Kamen > Deutschland
Phone +49 (0)2307/26070-0 > Fax +49 (0)2307/17050
Internet: www.emtest.com > E-mail: info@emtest.de
France
EM TEST FRANCE > Le Trident - Parc des Collines > Immeuble B1 - Etage 3 >
36, rue Paul Cézanne > 68200 Mulhouse > France
Phone +33 (0)389 31 23 50 > Fax +33 (0)389 31 23 55
Internet: www.emtest.fr > E-mail: info@emtest.fr
Poland
EM TEST Polska > ul. Ogrodowa 31/35, 00-893 Warszawa > Polska
Phone +48 (0)518 64 35 12
Internet: www.emtest.com/pl > E-mail: info.polska@emtest.de
Information about scope of delivery, visual design and technical data correspond with the state of development at time of release.\nTechnical
data subject to change without further notice.
USA / Canada
EM TEST USA Inc. > 9250 Brown Deer Road > San Diego > CA 92121
Phone +1 (858) 699 1685 > Fax +1 (858) 458 0267
Internet: www.emtest.com > E-mail: tom.revesz@ametek.com
P.R. China
EM TEST Representative Office Beijing > Rm 913, Leftbank >
No. 68 Bei Si Huan Xi Lu > Haidian District > Beijing 100080 > P.R. China
Phone +86 (0)10 82 67 60 27 > Fax +86 (0)10 82 67 62 38
Internet: www.emtest.com > E-mail: emtestbj@public.bta.net.cn
Malaysia
EM TEST (M) SDN BHD > Unit B2-6, Jalan Dataran SD2 > Dataran SD2, PJU9 >
Bandar Sri Damansara > 52200 Kuala Lumpur > Malaysia
Phone +60 (03)62 73 22 01 > Fax +60 (03)62 74 22 01
Internet: www.emtest.com > E-mail: sales@emtest.com.my