KARTA KATALOGOWA > UCS 200N-series > 20120209
UCS 200N SERIES
ULTRA COMPACT SIMULATORS FOR AUTOMOTIVE TRANSIENTS
DO BADAŃ ZGODNIE Z ...
> Audi (Reference vehicles)
> BMW - (Airbag ECU)
> BMW 600 13.0 (Part 2)
> BMW GS 95002 (1999)
> BMW GS 95002 (2001)
> BMW GS 95024-2-1 (2010-01)
> Case New Holland ENS0310
> Chrysler CS-11809 (2009)
> Chrylser CS-11979
> Chrysler DC-11224 Rev.A
> Chrysler PF-9326
> Claas CN 05 0215
> Cummins 14269 (982022-026)
> DaimlerChrysler DC-10614
> DaimlerChrysler PF-10540
> EN 300329
> EN 300340
> EN 300342-1
> EN 301489-1
> EN 301489-17
> EN 301489-24
> ...
ULTRA-COMPACT SIMULATORS FOR AUTOMOTIVE TRANSIENTS FOR PULSES 1, 2 AND 3A/3B
The UCS 200N Ultra-Compact Simulator series for Automotive Transients unifies the capabilites of an EFT/Burst simualtor, a
Micropulse simulator and the required coupling network into one box. The UCS 200N series is equiped to meet all
international and car manufacturer specifications from around the globe. The built-in coupling network ranges up to 200A
depending on the model. The built-in coupling network can be used and controlled by any unit of the LD 200N series,
VDS 200N series and PFS 200N series. For tests beyond standard's requirements the waveform parameters of the
Micropulse generator can be varied in a wide range by means of the FreeStyle mode.
HIGHLIGHTS
> Built-in EFT/Burst generator module
OBSZARY ZASTOSOWAŃ
AUTOMOTIVE
> Built-in Micropulse generator module (ISO 7637,
JASO, SAE and NISSAN)
TELECOM
> Built-in coupling network 60V, up to 200A
> Built-in battery switch
> Overcurrent protection
> USB and GPIB-Bus
www.emtest.com © EM TEST > STRONA 1/7
KARTA KATALOGOWA > UCS 200N-series > 20120209
PARAMETRY TECHNICZNE
BENEFITS
SMARTEST SOLUTION FOR AUTOMOTIVE TRANSIENT
TESTING
Never before an Ultra-Compact Simulator for automotive
transient testing like the UCS 200N series was available.
All international standards and most car manufacturer
requirements have been put into one box. All pulses are
fully compliant to the specifications. Even more, the
waveform parameters for micropulses can be varied in
order to test with pulses beyond any standard
specification.
The UCS 200N series is the heart of the redesigned EM
TEST Automotive test set-up having the ability to control
any external EM TEST Load Dump and Battery Supply
simulator. The built-in coupling network for nominal DC
currents of up to 200A forms the single-port DUT
connection for fully automated tests.
The software iso.control with its extensive standards
library put this test equipment to the top with almost
unlimited test capabilities.
SOFTWARE
ISO.CONTROL SOFTWARE FOR CONTROL AND
DOCUMENTATION
Outstanding user convenience, clearly structured
windows and operation features and the EM TEST
standards library along with the flexibility to generate
user specific test sequences very easily are the main
features of iso.control software. The software is
automatically configured according to the connected EM
TEST generators. iso.control software covers
international/national standards and most of the
manufacturer standards and is continuously updated.
Extensive reporting capabilities help the user to create
test reports that meet international requirements.
iso.control is supported by Windows 2000, Windows XP,
Windows Vista and Windows 7. Remote control is
achieved either via USB or GPIB. iso.control supports a
wide range of GPIB cards of National Instruments.
ACCESSORIES
OPERATION
EASY TO OPERATE
Front panel menu and function keys enable the user to
program his test routines quickly and accurately. The
cursor allows fast control of all test parameters of the
programmed routine, thus test procedures are simplified
and confidence is generated that every step is carried out
correctly.
ACC - CAPACITIVE COUPLING CLAMP
All lines other than supply lines are subjected to electrical
fast transient pulses by means of the ACC complying to
ISO 7637-3:2007
CA EFT KIT - VERIFICATION KIT FOR EFT/BURST PULSES
As per ISO 7637-2:2011 the characteristic of the burst
generator needs to be verified with two different loads 50
ohm and 1,000 ohm. EM TEST offers a calibration kit
consisting of the two loads and an adapter to verify the
pulses.
CA ISO - LOAD RESISTORS FOR PULSE VERIFICATION
A set of highly-accurate load resistors is unified in a
single box for the verification of micropulses and Load
Dump pulses as specified in ISO 7637-2:2011, Annex C
and a wide range of manufacturer specifications.
www.emtest.com © EM TEST > STRONA 2/7
KARTA KATALOGOWA > UCS 200N-series > 20120209
PARAMETRY TECHNICZNE
UCS 200N SERIES
UCS 200N MODELS
UCS 200N50 Built-in coupling/decoupling
network, 60V/50A, 100A@500ms
UCS 200N100 Built-in coupling/decoupling
network, 60V/100A, 150A@500ms
UCS 200N150 Built-in coupling/decoupling
network, 60V/150A
UCS 200N200 Built-in coupling/decoupling
network, 60V/200A
INPUT
DUT supply +/- DC voltage from VDS 200N or
any other DC supply
Pulse 5, 7 From one LD 200N
OUTPUT
DUT supply +/- Central DUT output
Coaxial output
port
To connect the capacitive coupling
clamp as per ISO 7637-3:2007
ELECTRICAL FAST TRANSIENTS
EFT/BURST MODULE FOR TEST PULSES 3A/3B
As per ISO 7637-2
Test voltage 25V - 1,000V ± 10%
Rise time 5ns ± 1.5ns
Pulse duration 150ns ± 45ns
Verification As per Annex C of ISO 7637-2:2011
into 50ohm and 1,000ohm load
Source impedance Zq = 50ohm
Polarity Positive/negative (Pulse 3b/3a)
TRIGGER CIRCUIT
Trigger of bursts Automatic, manual, external
Burst duration T4 = 0.1ms - 999.9ms
Repetition rate T5 = 10ms - 9,999ms
Spike frequency f = 0.1kHz - 200kHz
Test duration T = 0:01min - 999:59min
T > 999:59min --> endless
OUTPUTS
Direct Via 50ohm-coaxial connector
(for tests using e.g. a capacitive
coupling clamp)
Coupling mode To the + battery line (supply lines)
CRO trigger 5V trigger signal for oscilloscope
TEST ROUTINES
Quick Start On-line adjustable parameters,
easy-to-use
Standard Test
routines
User Test routines Random burst release
As per ISO 7637-2:2011, Levels 1 - 4
Change voltage after T
Change frequency after T
www.emtest.com © EM TEST > STRONA 3/7