Atec T-R-100ADM Mk4 User Manual

100ADM Current Injection System
mk4
Features
Clear and simple user interface
0-100A output current
Current limit mode for fine current
control
True RMS metering with single
cycle capture memory ammeter
system
Auxiliary DC and AC output
Large back-lit liquid crystal display
Thermal and over-current protection
Compact and portable
Automatic mains voltage selection
The 100ADM mk4 provides commissioning and maintenance engineers with a flexible system for testing protective systems. It has an easy to understand panel layout and a simple user interface. The status of every function can be seen at a glance, and there are no complex menus to navigate.
The 100ADM mk4 keeps the familiar user interface of previous models but adds a new metering system that accurately measures the RMS of a single cycle. It also features a new current limit mode to provide very fine control of low currents, even into low impedance loads. Current limit mode also assists in testing self-powered overcurrent protection as fitted to many 11kV ring main units.
The back-lit display on the 100ADM mk4 is bright and
clear with a wide viewing angle. The results of a test can
be seen here as they appear on the display.
A 24-220VDC switch-mode stabilised DC supply with current limiting is provided to power the relay under test. An isolated, separately switched 110VAC auxiliary supply is also provided.
Shoulder carry strap
The unit has a range of outputs allowing injection of currents as low as a few mA and as high as 100A. Voltages up to 240V are available allowing high impedance current relays and voltage relays to be tested. Four true RMS metering ranges are provided, and the full scale of the meter (and trip level) can be set independently of output tap. Industry standard safety connectors are used on all inputs and outputs for convenience, reliability and safety.
A very flexible two channel timing system is provided, allowing trip times, reset times and reclose times to be quickly measured to a high degree of accuracy. The timer auto-ranges to measure from 1ms to 99999.9s.
The outputs of the 100ADM mk4 are well protected. The main output is protected by overcurrent, duty cycle and thermal trips. The auxiliary dc supply is protected by a current limit, and the auxiliary AC supply is fuse protected.
The unit is supplied with a comprehensive lead set in a sturdy carrying case.
100ADM mk4 Applications
IEEE no. Type
27/59 Under/over voltage 37 Undercurrent 50/76 Instantaneous overcurrent Ground fault relay 51 IDMT overcurrent relay 59G Neutral voltage displacement 67 Directional overcurrent (basic
tests)
IEEE no. Type
79 Auto recloser 86 Lockout relay 94 Tripping relay 90V Voltage regulating relay Miniature circuit breakers
Circuit breakers for equipment
Thermal relays
7
100ADM mk4 Specification
Main Output
The main output on the unit has four taps, allowing the selection of output voltages up to 240V and output currents up to 100A.
Range
Current
Cont 5 min* 1 min* O/C Load V
10V 33A 67A 100A 10.5V 8.7V@100A
35V 10A 20A 30A 36V 32V@30A
100V 3A 6A 10A 108V 99V@10A
240V 1A 2A 3A 276V 259V@3A
240Vdc
*Off time of 15 minutes. On times based on an ambient temperature of 25°C. **6 second intermittent ratings available with 230V supply.
1A 2A 3A
I Limit Mode
The main output has a current limit mode that gives very fine control of output currents up to 10A. It also allows fine current control into very low impedance loads such as digital relays.
Current (A)
Range
10V 10A 3A 6A 10A 8.6V 5V@5A
Short
circuit
Cont. 5 min 2 min O/C Load V
Output @230V
Output V @230V
Timing System
Range 0-999.999s/9999.99s/99999.9s autoranging Resolution 1/10/100ms Accuracy 0.01%rdg+2d (+4d current operated mode) Contact o/c 24V Contact s/c 20mA Vdc 24240V
Each contact circuit will auto-select for normally open or normally closed contacts. A DC voltage of 24240VDC may also be used to trigger either timer channel. Contact state is shown by an LED. The output automatically switches off at the end of the test to safeguard the relay under test.
Mode Timer Start Timer Stop
Internal start Press ‘ON’
1 contact C1 1st change
2 contacts C1 change C2 change
Current operated Current > 10% of Current < 10% of
Pulse Press ‘ON’ 200ms
Pulse mode is used for setting the current level in devices sensitive to heating. Current is injected for 200ms.
C1 or C2 change
C1 1 2nd change
35V 3A 1A 2A 3A 29V 13V@2A
100V 1A 0.3A 0.6A 1A 88V 40V@0.6A
240V 0.3A 0.1A 0.2A 0.3A 224V 130V@0.2A
Auxiliary AC and DC Outputs
A switched, isolated auxiliary DC supply with current limit protection is available to power the relay under test, and a 110Vac auxiliary output is available for tests.
DC stabilised output 24V, 48V, 60V 1.0A 110V, 220V 0.23A Fixed AC output 110Vac 300mA
Metering
The output is metered by a digital true RMS system with a single cycle capture memory ammeterwhenever the timer stops and the output is switched off, the reading is held on the display. A current trip is set to 110% of full scale of the selected metering range.
Range Resolution
Trip
current
Accuracy
Acquisition
time
2.000A 0.001A 2.2A ±0.5%rdg±5d 20ms
10.00A 0.01A 11A ±0.5%rdg±5d 20ms
20.00A 0.01A 22A ±0.5%rdg±5d 20ms
100.0A 0.1A 110A ±0.5%rdg±5d 20ms
Supply Requirements
115/230V±10% auto-selecting 50/60Hz 1ph 1200VA max
Accessories
Operating manual, output lead set, mains lead, spare fuses and carry strap.
RS232 and T&R Link
An RS232 port is provided to allow connection to a PC or a printer. The T&R Link output allows a T&R DVS3 mk2 voltage source to phase lock to the 100ADM mk4 current..
Protection and Safety
The unit is designed to comply with BSEN61010 and is CE marked. An earth terminal is provided for connection to a local earth for testing in sub-station environments.
Dimensions Weight
380mm x 314mm x 221mm 20.0kg
Including handle and corner protectors
Temperature Range
Storage -20°C to 60°C Operating 0°C to 45°C
Lead Set specifications
The 100ADM mk4 is supplied with a lead set consisting of:
2 x 5m 25mm 2 x 5m, 2 x 0.5m 2.5mm
2
100A leads terminated in M10 ring crimps
2
25A leads terminated in 4mm plugs
1 x 5m 2 core 0.75mm2 lead terminated in 4mm plugs The lead set is supplied in a plastic carrying case. Lead set weight 5.3kg including case.
Optional Accessories
Filter unit, RB10 resistor box, Printer, pushbutton lead for runback timing on disc induction relays.
The standard 100ADM mk4 is supplied in an aluminium case. It is also optionally available mounted in a Pelicase with space for leads.
Note: Due to the company’s continuous research programme, the information above may change at any time without prior notification. Please check that you have the most recent data on the product.
8
T&R Test Equipment Ltd, 15-16 Woodbridge Meadows, Guildford, Surrey, GU1 1BJ, UK
Tel: +44 (0)1483 207428 Fax: +44 (0)1483 511229 email: sales@trtest.com
www.trtest.com
100ADM mk4 Data Sheet Rev 1 03/10/12