Atec TOS6100 User Manual

OPTIONS
FOR ELECTRICAL SAFETY TESTERS
The separately sold accessories shown here can all be used with the withstanding voltage testers and insulation resistance testers shown in this catalog with the exception of the limiting conditions for each item. Since some of these accessories may not be able to be used with previous types not described in this catalog, please ask your dealer or the manufacturer when conditions are unclear.
Remote Control Box
This enables test on and reset operations to be performed by remote control.
RC01-TOS [one-hand operation/dimensions: 200W × 70H × 39D mm]
RC02-TOS [both-hands operation/dimensions: 330W × 70H × 39D mm] Accessory cable length: 1.5 m
Note:The optional Adapter DD-5P/6P (DIN to Mini DIN) is required for the connection with TOS7200
RC01-TOS RC02-TOS
DIN Cable DD-3 5P [cable length: 3m (For RC01-TOS, RC02-TOS)]
High-Voltage Test Lead
TL01-TOS
[cable length: 1.5 m/max. operating voltage: 5 kV]
TL02-TOS [cable length: 3 m/max. operating voltage: 5 kV]
TL03-TOS [cable length: 1.5 m/max. operating voltage: 10 kV]
TL04-TOS [cable length: 1.5 m/max. operating voltage: 5 kV (for TOS1200, RL01-TOS)]
TL05-TOS [cable length: 1.5 m/max. operating voltage: 5 kV
(for TOS7000 series, 149-10A, RL01-TOS)]
TL06-TOS [cable length: 0.5 m/max. operating voltage: 5 kV
(for parallel connection of TOS9220/9221)]
TL07-TOS [cable length: 1.5 m/max. operating voltage: 5 kV (for TOS9220/9221)]
TL08-TOS [cable length: 1.5 m/max. operating voltage: 1 kV (for TOS7200)]
HTL-2.5DH
[cable length: 1.5 m/max. operating voltage: 10 kV (for 149-10A)]
High-Voltage Test Probe
(mainly for withstanding voltage testers) These are handy probes for use with withstanding voltage testers. These probes employ a design in which all test switches on the probe can be pressed when holding onto the probe by its grip.
HP01A-TOS [cable length:
1.5 m/max. operating voltage: 4 kV AC (RMS), 5 kV DC]
HP02A-TOS [cable length: 3
m/max. operating voltage: 4 kV AC (RMS), 5 kV DC]
Low-Voltage Test Leads (for TOS6100/6200)
Test leads with alligator clips are to be used exclusively for earth continuity testing.
TL11-TOS [cable length: 1.5 m /
max.operating current: 30A]
Low-Voltage Test Probe (for TOS6100/6200)
This test probe is to be used exclusively for earth continuity testing. Test on and reset can be performed using the switch on the probe.
LTP-2 [cable length: 2 m/
max.operating current: 30A]
TL01-TOS TL02-TOS TL03-TOS TL04-TOS
TL05-TOS TL06-TOS TL07-TOS TL08-TOS
HTL-2.5DH
Please contact your dealer or the manufacturer in cases when
electrically insulated gloves, electrically insulated rubber sheets and so forth are required.
Warning Light Unit
This warning light unit is used to indicate the status of withstanding voltage testers (test or judgement). This unit can be turned on and off by a 100 V AC input or a make contact signal.
PL01-TOS
* This can not be used with TOS6200,
TOS9200/9201, TOS7200
Buzzer Unit
This buzzer unit is used when the volume obtained with the electronic buzzer incorporated in withstanding voltage testers is not sufficient. This unit can be turned on and off by a 100 V AC input or make contact signal.
* This can not be used with TOS6200,
TOS9200/9201, TOS7200
BZ01-TOS
Page1Copyright © 2002 KIKUSUI ELECTRONICS CORP. All rights reserved. http://www.kikusui.co.jp/
TOS1200
OPTIONS
FOR ELECTRICAL SAFETY TESTERS
Outlines
Model TOS1200 Withstanding Voltage Tester Current Calibrator: For calibration of current sensitivity of withstanding voltage testers
Calibration of Leakage Current Detection Sensitivity
As a result of containing an internal test load resistor, the TOS1200 enables switching of ammeter sensitivity and load resistance values automatically for easy calibration of the sensitivity of leakage current detection.
Direct Reading of Error from Error Display Scale
The main scale consists of an error display scale ranging from -10% to +10% around a central full scale value. Thus, if the leakage current detection sensitivity of the withstanding voltage tester is a value of 1, 2 and 5 steps or 1, 2, 4 and 8 steps, the error can be read directly from the scale. The auxiliary scale consists of a ratio display scale in which the full scale value is taken to be 1.1, thereby enabling accommodation of values outside the range of the main scale.
Ammeter Ranges
The ranges of the ammeter consist of 0.5, 1, 2, 5, 10, 20, 50 and 100 mA, and values equal to 0.8 times those values can be set. This is convenient for withstanding voltage testers of the type in which leakage current detection sensitivity is set digitally (1, 2, 4 and 8 steps).
Eliminates Need for Power Supply
The TOS1200 offers outstanding portability since it does not require a power supply.
AC/DC Selection Switch
Specifications
Measuring Function Measurement of current values and
error (%) for AC (50/60 Hz) and DC at a test voltage of 1000 V
Measuring Ranges 8 ranges consisting of 0.5/1/2/5/10/20/
50/100 mA along with values equal to
0.8 times the values of those ranges (for 1, 2, 4 and 8 steps)
Ammeter Scale Main scale: Direct-reading error
Ammeter Accuracy Main scale: ±1% of reading
Ammeter Indication D C/AC(sine wave rms value
Load Resistance
Resistance[kΩ]Range[mA]
0.5 1 2 5
Allowed Input Time 0.5/1/2/5 mA ranges: Continuous
Dimensions (MAX) 134W × 164H × 270D mm
Weight approx. 3.5 kg Accessories TL04-TOS high-voltage test lead: 1
2000 1000
500 200
display scale over a range of ±10% of the above full scale values Auxiliary scale: Ratio scale of 0 to 1.1 times the above full scale values (equivalent to 0% display of main scale when the ratio is equal to 1)
Auxiliary scale: ±3% of full scale value
calibration of mean value response)
Resistance[kΩ]Range[mA] 10 20 50
100
10/20/50/100 mA ranges: 60 sec. Max. 1/3 of duty cycle
(140W × 189H × 320D mm)
100
50 20 10
Page2Copyright © 2002 KIKUSUI ELECTRONICS CORP. All rights reserved. http://www.kikusui.co.jp/
OPTIONS
FOR ELECTRICAL SAFETY TESTERS
149-10A
Outlines
Model 149-10A High-Voltage Digital Voltmeter:
Accommodation of Output Voltage Calibration of Withstanding Voltage and Insulation Resistance Testers
Measurement of high voltages (AC/DC) of up to 10 kV
maximum.
Large 41/ ❏High measuring accuracy and input resistanceLight weight of only 3.2 kgCompact designExcellent ease of maintenance
digit LED display
2
RL01-TOS
Rear Panel
Model RL01-TOS UL Resistance Load: Checking of Output
Voltage of Withstanding Voltage Testers This device is described in section 125, paragraph 2-1B1 of UL1492. The RL01-TOS is a variable load resistor for checking the output voltage of withstanding voltage testers used in dielectric strength testing on production lines. (Complies with UL regulations including UL1270, UL1409 and UL1410.)
Specifications
Resistors: 120, 159, 210, 279, 369, 489, 648, 858,
1,137, 1,500, 1,989 and 2,148 k
Resistance Accuracy +1%,-0% of nominal value when set
to 120 k, ±1% of nominal value when
set to other values Maximum OperatingVoltage 1300 V (continuous rating) Maximum Overload Voltage 1400 V for 5 seconds (application may
not be repeated within 1 minute) Dimensions (MAX) 200W × 100H × 260D mm
(210W × 120H × 295D mm) Weight approx. 2.6 kg Accessories TL04-TOS high-voltage test lead: 2
TL05-TOS high-voltage test lead: 1
Specifications
Operating System Double integration system (sampling
cycle: 3 times/sec)
DC Voltage Measuring range: 0.500kV to
10,000kV Accuracy: ±(0.5% of reading + 0.03% of range) Input resistance: 1000 MΩ ± 2%
AC Voltage Measuring range: 0.500kV to
10,000kV Accuracy: ±(1% of reading + 0.05% of range) Frequency characteristics: 50/60 Hz (sine wave rms value display of mean value response) Input resistance: 1000 MΩ ± 2% Power Requirements 100V±10%, approx. 10 VA
Dimensions (MAX) 134W × 164H × 270D mm
(140W × 189H × 350D mm)
Weight approx. 3 kg Accessories TL05-TOS high-voltage test lead: 1
HTL-2.5DH high-voltage coaxial cable: 1
Page3Copyright © 2002 KIKUSUI ELECTRONICS CORP. All rights reserved. http://www.kikusui.co.jp/
Loading...