
Fluke TiR1 and
TiR Thermal Imagers
Optimized for building
envelope, restoration and
remediation, inspection
and roofing applications.
The new Fluke TiR1 and TiR Thermal Imagers are the perfect
imagers for building envelope, restoration and remediation,
inspection and roofing applications.
• All Fluke imagers come with IR-Fusion
camera and software (combines visible image with IR image
in full screen or picture-in-picture views) for easy identification and reporting of problems
• Rugged and reliable: Engineered to withstand a 2 m
(6.5 ft) drop
• 9.1 cm (3.6 in) diagonal landscape color VGA
(640 x 480) LCD
• Temperature range and thermal sensitivity optimized for
building diagnostics applications
• Excellent thermal sensitivity for seeing even small
temperature differences (which could indicate problems)
• Adjustable hand strap for left- or right-handed users
• Manufactured in the U.S.A.
Technical Data
®
Technology both in
IR-Fusion® Technology
See things both ways—Infrared and
visual (visible light) images fused
together communicating critical information faster and easier—traditional
infrared images are no longer enough.
Fluke led the way in the development
and use of IR-Fusion and the industry followed. Both visible and infrared
images allow you to communicate
exactly where potential savings can be
gained. IR-Fusion is standard on Fluke
TiR1 and TiR models.

Detailed specifications
Fluke TiR1 Fluke TiR
Temperature
Temperature measurement range
(not calibrated below -10 °C)
Accuracy ± 2 °C or 2 % (whichever is greater) ± 5 °C or 5 % (whichever is greater)
Measurement modes Smooth auto-scaling and manual scaling
On-screen emissivity correction Yes —
Imaging performance
Field of view 23° x 17°
Spatial resolution (IFOV) 2.5 mRad
Minimum focus distance Thermal lens: 15 cm (6 in); Visible (visual) light lens: 46 cm (18 in)
Focus Manual, one-handed focus
Image frequency 9 Hz refresh rate
Detector type 160 X 120 focal plane array, uncooled microbolometer
Infrared lens type 20 mm F = 0.8 lens
Thermal sensitivity (NETD) ≤ 0.07 °C at 30 °C (70 mK) ≤ 0.1 °C at 30 °C (100 mK)
Infrared spectral band 7.5 μm to 14 μm
Visual camera 640 x 480 resolution
Image presentation
Palettes Ironbow, blue-red, high contrast,
amber, hot metal, grey
Level and span Smooth auto-scaling and manual scaling of level and span
Minimum span (in manual mode) 2.5 °C (4.5 °F)
Minimum span (in auto mode) 5 °C (9 °F)
®
IR-Fusion
information Full Infrared with MAX, MID, or MIN
automatic blending; and Picture-in-Picture
with MAX, MID, or MIN automatic blending
Visual and IR blending
Picture-In-Picture (PIP) Three levels of on-screen IR blending
displayed in center 320 x 240 pixels
Full screen (PIP off) Three levels of on-screen IR blending
displayed in center 640 x 480 LCD
Voice annotation
Voice annotation 60 seconds maximum recording time per image —
Image and data storage
Storage medium SD memory card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked
visual images each with 60 seconds voice annotations or 3000 basic (.bmp) IR images
File formats Non-radiometric (.bmp) or fully-radiometric (.is2)
Export file formats
®
w/SmartView
software
-20 °C to +100 °C (-4 °F to + 212 °F)
Ironbow, blue-red, high contrast, grey
Full Infrared or Picture-in-Picture
100 % IR displayed in center
320 x 240 pixels
100 % IR displayed in center
640 x 480 LCD
No analysis software required for .bmp files
JPEG, BMP, GIF, PNG, TIFF, WMF, EXIF, and EMF
2 Fluke Corporation TiR1 and TiR Thermal Imagers

General specifications
Temperature Operating: -10 °C to 50 °C (14 °F to 122 °F)
Storage: -20 °C to +50 °C (-4 °F to 122 °F) without batteries
Relative humidity 10 % to 90 % non-condensing
Display 9.1 cm (3.6 in) diagonal landscape color VGA (640 x 480) LCD with backlight (selectable bright or auto)
Controls and adjustments User selectable temperature scale (°C/°F)
Language selection
Time/date set
Emissivity selection and reflected background temperature compensation (TiR1 only)
User selectable hot spot and cold spot on the image (TiR1 only)
TiR1 allows user to adjust palette, alpha blend, level, span, PIP, and emissivity on a
captured image before it is stored.
®
Software SmartView
Power Battery: Internal rechargeable battery pack (included)
Battery life: 3 to 4 hours continuous use (assumes 50 % brightness of LCD)
Battery charge time using ac adapter/charger or dc car charger: 2 hours for full charge
AC operation/charging AC adapter/charger (110 V ac to 220 V ac, 50 Hz to 60 Hz). Charges battery while
imager is operating. Universal ac mains adapters included.
Power saving Sleep mode activated after 5 minutes of inactivity, automatic power off after 30 minutes of inactivity
Safety standards CE Directive: IEC/EN 61010-1 2nd Edition Pollution Degree 2
Electromagnetic
compatibility
EMC directive: EN61326-1
C-Tick: IEC/EN 61326
US FCC: CFR 47, Part 15 Class A
Vibration 2 G, IEC 68-2-29
Shock 25 G, IEC 68-2-29 (2 m or 6.5 ft drop, 8 sides)
Dimensions (HxWxL) 0.27 m x 0.13 m x 0.15 m (10.5 in x 5 in x 6 in)
Weight 1.2 kg (2.65 lb)
IP rating IP54
Warranty Two-years
Calibration cycle Two-years (assumes normal operation and normal aging)
Supported languages English, Italian, German, Spanish, French, Russian, Portuguese, Swedish, Turkish, Czech,
Polish, Finnish, Simplified Chinese, Traditional Chinese, Korean, and Japanese
full analysis and reporting software included
Ordering information
FLUKE-TIR1 Thermal Imager
FLUKE-TIR Thermal Imager
Included with product
Thermal imaging camera w/20 mm lens, ac power
supply/battery charger (including mains adapters), SD memory card, SD card reader
(USB) for downloading images into your computer, SmartView
software upgrades for life, rugged hard, carrying case, soft transport bag, hand strap,
users manual, warranty registration card, and interactive training DVD.
Optional accessories
Fluke-TI Charger Thermal Imager Car Charger
Fluke-T-Visor Thermal Imager Visor
3 Fluke Corporation TiR1 and TiR Thermal Imagers
®
software with free
Fluke. Keeping your world
up and running.
Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2007-2009 Fluke Corporation.
Specifications subject to change without notice.
Printed in U.S.A. 1/2009 3035363 D-EN-N Rev C
Modification of this document is not permitted
without written permission from Fluke Corporation.
®