The experts’ choice for
problem solving and
preventive/predictive
maintenance
Features
High resolution, low noise VOx detector
for high quality images
Temperature range to cover broad
industrial applications
High thermal sensitivity for viewing even
the smallest temperature differences
180 ° articulating flexible lens to view
images in every situation
Choice of 3 interchangeable lenses to
cover every application*
Large 5 inch high contrast color LCD
for a clear picture independent of
lighting conditions
Fully radiometric for detailed
temperature analysis and tracking
SmartFocus for best image quality and
accurate temperature measurements
Windows CE based menu structure
for ease of use
Personalized instrument set-up for
multiple person use
CompactFlash memory cards to store over
1000 IR images plus fully
radiometric temperature data
SmartView® reporting and analysis
software included
AutoCapture for making intermittent
problems visible
On-board analysis functions
User defined text annotations for
simplified reporting
Built-in visible (visual) light camera
IR-Fusion blending thermal and
visible light images
IR/Visible Alarm function
Laser pointer for easy targeting
Flash and torch light for high quality
images in dark environments
*10 mm and 54 mm lenses are optional and are only available at time of initial order.
Ti55FTTi50FT
320 x 240
-20 °C to +600 °C
(-4 °F to 1112 °F)
≤0.05 °C at
30 °C (50 mK)
••
••
••
••
••
••
••
••
••
•
•
•
••
••
•
••
••
-20 °C to +350 °C
(-4 °F to 662 °F)
≤0.07 °C at
30 °C (70 mK)
Technical Data
The Fluke Ti55FT and Ti50FT models
feature everything needed for virtually any
thermography task.
Fluke FlexCam Thermal Imagers come
standard with the patent-pending Fluke
IR-Fusion
light) images with infrared images.
SmartView
software is included with each purchase
along with free software upgrades for
the life of your product.
These models feature 320 x 240
detectors and temperature sensitivity
(NETD) down to 0.05 °C (50 mK) in the
higher end model.
Choose Fluke FlexCam Thermal Imagers
when you need industry leading thermal
sensitivity for high resolution, ultra
high-quality images.
Typical applications:
Troubleshooting—Pinpointing the location of
•
Preventive/predictive maintenance—
•
Industrial maintenance—Check whether
•
Process monitoring—Real-time observa-
•
Quality control—Examine prototypes and
•
• Research and development—Quantify
• Electronic design—Circuit board analysis.
®
Technology fusing visual (visible
®
IR analysis and reporting
specific problems in equipment and systems.
Identify electrical and mechanical problems
before they cause failure.
repairs have been performed correctly.
tion to ensure efficient and safe operations.
refine thermal management designs.
heat patterns to improve product designs.
Page 2
Detailed specifications
Detailed Specifications
Fluke Ti55FTFluke Ti50FT
Imaging performance
Field of view (FOV)*23° horizontal x 17° vertical
Spatial resolution (IFOV)*1.30 mrad
Min focus distance*0.15 m (5.9 in)
Thermal sensitivity (NETD)≤ 0.05 °C at 30 °C (50 mK)≤ 0.07 °C at 30 °C (70 mK)
Detector data acquisition/image
frequency
FocusSmartFocus; one finger continuous focus (manual)
IR digital zoom2x, 4x, 8x2x
Detector type320 x 240 Focal Plane Array, Vanadium Oxide (VOx) Uncooled Microbolometer
Spectral band8 µm to 14 µm
Digital image enhancementAutomatic full time enhanced
On camera operating modesFull thermal, full visual light or merged
Visible light camera1280 x 1024 pixels, full color
Visible light digital zoom2x, 4x2x
Temperature measurement
Calibrated temperature range-20 °C to 600 °C (-4 °F to 1112 °F)
in three ranges
Range one =-20 °C to
100 °C (-4 °F to 212 °F)
Range two = -20 °C to
350 °C (32 °F to 662 °F)
Range three = 250 °C to 600 °C
(482 °F to 1112 °F)
Accuracy± 2 °C or 2 % (whichever is greater)
Measurement modesCenterpoint, center box (area min/max, average),
moveable spots/boxes, user defined field/text
annotations, automatic hot and cold point
detection, visible color alarm above and below
Emissivity correction0.1 to 1.0 (0.01 increments)
Image presentation
Digital display 13 cm (5 in) diagonal large high-resolution digital display
LCD backlightSunlight readable color LCD
Video outputRS170 EIA/NTSC or CCIR/PAL composite video
PalettesGrayscale, grayscale inverted, blue red, high contrast, hot metal,
ironbow, amber, amber inverted
Optical lenses
54 mm telephoto lensHigh precision Germanium lens
Field of view (FOV): 9° horizontal x 6° vertical
Spatial resolution (IFOV): 0.47 mrad
Min focus distance: 0.6 m (1.97 ft)
10.5 mm wide angle lensHigh precision Germanium lens
Field of view (FOV): 42° horizontal x 32° vertical
Spatial resolution (IFOV): 2.45 mrad
Min focus distance: 0.3 m (0.98 ft)
*Standard 20 mm Germanium lens
60 Hz/60 Hz
thermal-visual images.
Picture-in-Picture
-20 °C to 350 °C (-4 °F
to 662 °F) in two ranges
Range one = -20 °C to
100 °C (-4 °F to 212 °F)
Range two = -20 °C to
350 °C (32 °F to 662 °F)
Centerpoint, center box
(area min/max, average)
2 Fluke Corporation Ti55FT and Ti50FT Thermal Imagers with IR-Fusion
Page 3
General specifications
Fluke Ti55FTFluke Ti50FT
Image and data storage
Storage mediumCompact flash card stores over 1000 IR images (1 GB card standard)
File formats supported 14 bit measurement data included. Exportable Images: bmp, gif, jpg, png, tiff;
Interface and software
InterfaceCompact flash card reader included
SoftwareSmartView; Full analysis and reporting software included
Laser
ClassificationClass II
Laser targetingLaser dot visible on screen when blending thermal and visible image
Controls and adjustments
Set-up controlsDate/time, temperature units C/F, language, scale, LCD intensity (high/normal/low)
Image controlsLevel, span, auto adjust (continuous/manual)
On-screen indicatorsBattery status, target emissivity, background temperature and realtime clock
Power
Battery typeLi-Ion smart battery, rechargeable, field-replaceable (two included)
Battery operating timeTwo hours continuous operation (per battery)
Battery chargingTwo bay intelligent charger powered via ac outlet
Continuous ac operationAC adapter 110/220 V ac, 50/60 Hz—
Power savingAutomatic shutdown and sleep modes (user specified)
Environmental and mechanical design
Operating temperature-10 °C to +50 °C (14 °F to 122 °F)
Storage temperature-40 °C to +70 °C (-40 °F to 158 °F)
Relative humidityOperating and storage 10 % to 95 %, non-condensing
Water and dust resistantIP54
Weight (including batteries)1.95 kg (4.3 lb)
Camera size (H x W x D)162 mm x 262 mm x 101 mm (6.5 in x 10.5 in x 4.0 in)
Other
WarrantyTwo-years
Data formats: comma separated (csv), tab separated (txt).
Ordering information
FLK-Ti50FT-20 IR FlexCam Thermal Imager with IR-Fusion
FLK-Ti55FT-20 IR FlexCam Thermal Imager with IR-Fusion
Included with product
Heavy duty carrying case, 2 rechargeable
battery packs, battery charger, ac adapter
(with Ti55FT only), video cable, 512 MB
compact flash card, compact flash
card reader and USB cable, PCMCIA
compact flash card reader, neck strap,
printed getting started guide, SmartView
reporting and analysis, software on CD,
complete user manual on CD
3 Fluke Corporation Ti55FT and Ti50FT Thermal Imagers with IR-Fusion
Fluke. Not just infrared. Infrared you can use.
Fluke Corporation
PO Box 9090, Everett, WA U.S.A. 98206
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com