Fluke Ti55FT and
Ti50FT FlexCam
®
Thermal Imagers
The experts’ choice for
problem solving and
preventive/predictive
maintenance
Features
High resolution, low noise VOx detector
for high quality images
Temperature range to cover broad
industrial applications
High thermal sensitivity for viewing even
the smallest temperature differences
180 ° articulating flexible lens to view
images in every situation
Choice of 3 interchangeable lenses to
cover every application*
Large 5 inch high contrast color LCD
for a clear picture independent of
lighting conditions
Fully radiometric for detailed
temperature analysis and tracking
SmartFocus for best image quality and
accurate temperature measurements
Windows CE based menu structure
for ease of use
Personalized instrument set-up for
multiple person use
CompactFlash memory cards to store over
1000 IR images plus fully
radiometric temperature data
SmartView® reporting and analysis
software included
AutoCapture for making intermittent
problems visible
On-board analysis functions
User defined text annotations for
simplified reporting
Built-in visible (visual) light camera
IR-Fusion blending thermal and
visible light images
IR/Visible Alarm function
Laser pointer for easy targeting
Flash and torch light for high quality
images in dark environments
*10 mm and 54 mm lenses are optional and are only available at time of initial order.
Ti55FT Ti50FT
320 x 240
-20 °C to +600 °C
(-4 °F to 1112 °F)
≤0.05 °C at
30 °C (50 mK)
• •
• •
• •
• •
• •
• •
• •
• •
• •
•
•
•
• •
• •
•
• •
• •
-20 °C to +350 °C
(-4 °F to 662 °F)
≤0.07 °C at
30 °C (70 mK)
Technical Data
The Fluke Ti55FT and Ti50FT models
feature everything needed for virtually any
thermography task.
Fluke FlexCam Thermal Imagers come
standard with the patent-pending Fluke
IR-Fusion
light) images with infrared images.
SmartView
software is included with each purchase
along with free software upgrades for
the life of your product.
These models feature 320 x 240
detectors and temperature sensitivity
(NETD) down to 0.05 °C (50 mK) in the
higher end model.
Choose Fluke FlexCam Thermal Imagers
when you need industry leading thermal
sensitivity for high resolution, ultra
high-quality images.
Typical applications:
Troubleshooting—Pinpointing the location of
•
Preventive/predictive maintenance—
•
Industrial maintenance—Check whether
•
Process monitoring—Real-time observa-
•
Quality control—Examine prototypes and
•
• Research and development—Quantify
• Electronic design—Circuit board analysis.
®
Technology fusing visual (visible
®
IR analysis and reporting
specific problems in equipment and systems.
Identify electrical and mechanical problems
before they cause failure.
repairs have been performed correctly.
tion to ensure efficient and safe operations.
refine thermal management designs.
heat patterns to improve product designs.
Detailed specifications
Detailed Specifications
Fluke Ti55FT Fluke Ti50FT
Imaging performance
Field of view (FOV)* 23° horizontal x 17° vertical
Spatial resolution (IFOV)* 1.30 mrad
Min focus distance* 0.15 m (5.9 in)
Thermal sensitivity (NETD) ≤ 0.05 °C at 30 °C (50 mK) ≤ 0.07 °C at 30 °C (70 mK)
Detector data acquisition/image
frequency
Focus SmartFocus; one finger continuous focus (manual)
IR digital zoom 2x, 4x, 8x 2x
Detector type 320 x 240 Focal Plane Array, Vanadium Oxide (VOx) Uncooled Microbolometer
Spectral band 8 µm to 14 µm
Digital image enhancement Automatic full time enhanced
On camera operating modes Full thermal, full visual light or merged
Visible light camera 1280 x 1024 pixels, full color
Visible light digital zoom 2x, 4x 2x
Temperature measurement
Calibrated temperature range -20 °C to 600 °C (-4 °F to 1112 °F)
in three ranges
Range one =-20 °C to
100 °C (-4 °F to 212 °F)
Range two = -20 °C to
350 °C (32 °F to 662 °F)
Range three = 250 °C to 600 °C
(482 °F to 1112 °F)
Accuracy ± 2 °C or 2 % (whichever is greater)
Measurement modes Centerpoint, center box (area min/max, average),
moveable spots/boxes, user defined field/text
annotations, automatic hot and cold point
detection, visible color alarm above and below
Emissivity correction 0.1 to 1.0 (0.01 increments)
Image presentation
Digital display 13 cm (5 in) diagonal large high-resolution digital display
LCD backlight Sunlight readable color LCD
Video output RS170 EIA/NTSC or CCIR/PAL composite video
Palettes Grayscale, grayscale inverted, blue red, high contrast, hot metal,
ironbow, amber, amber inverted
Optical lenses
54 mm telephoto lens High precision Germanium lens
Field of view (FOV): 9° horizontal x 6° vertical
Spatial resolution (IFOV): 0.47 mrad
Min focus distance: 0.6 m (1.97 ft)
10.5 mm wide angle lens High precision Germanium lens
Field of view (FOV): 42° horizontal x 32° vertical
Spatial resolution (IFOV): 2.45 mrad
Min focus distance: 0.3 m (0.98 ft)
*Standard 20 mm Germanium lens
60 Hz/60 Hz
thermal-visual images.
Picture-in-Picture
-20 °C to 350 °C (-4 °F
to 662 °F) in two ranges
Range one = -20 °C to
100 °C (-4 °F to 212 °F)
Range two = -20 °C to
350 °C (32 °F to 662 °F)
Centerpoint, center box
(area min/max, average)
2 Fluke Corporation Ti55FT and Ti50FT Thermal Imagers with IR-Fusion