Atec Ti50FT, Ti-55FT User Manual

Fluke Ti55FT and Ti50FT FlexCam
®
Thermal Imagers
The experts’ choice for problem solving and preventive/predictive maintenance
Features
High resolution, low noise VOx detector for high quality images
Temperature range to cover broad industrial applications
High thermal sensitivity for viewing even the smallest temperature differences
180 ° articulating flexible lens to view images in every situation
Choice of 3 interchangeable lenses to cover every application*
Large 5 inch high contrast color LCD for a clear picture independent of lighting conditions
Fully radiometric for detailed temperature analysis and tracking
SmartFocus for best image quality and accurate temperature measurements
Windows CE based menu structure for ease of use
Personalized instrument set-up for multiple person use
CompactFlash memory cards to store over 1000 IR images plus fully radiometric temperature data
SmartView® reporting and analysis software included
AutoCapture for making intermittent problems visible
On-board analysis functions
User defined text annotations for simplified reporting
Built-in visible (visual) light camera
IR-Fusion blending thermal and visible light images
IR/Visible Alarm function
Laser pointer for easy targeting
Flash and torch light for high quality images in dark environments
*10 mm and 54 mm lenses are optional and are only available at time of initial order.
Ti55FT Ti50FT
320 x 240
-20 °C to +600 °C (-4 °F to 1112 °F)
0.05 °C at
30 °C (50 mK)
-20 °C to +350 °C (-4 °F to 662 °F)
0.07 °C at
30 °C (70 mK)
Technical Data
The Fluke Ti55FT and Ti50FT models feature everything needed for virtually any thermography task. Fluke FlexCam Thermal Imagers come standard with the patent-pending Fluke IR-Fusion light) images with infrared images. SmartView software is included with each purchase along with free software upgrades for the life of your product. These models feature 320 x 240 detectors and temperature sensitivity (NETD) down to 0.05 °C (50 mK) in the higher end model. Choose Fluke FlexCam Thermal Imagers when you need industry leading thermal sensitivity for high resolution, ultra high-quality images.
Typical applications:
Troubleshooting—Pinpointing the location of
Preventive/predictive maintenance—
Industrial maintenance—Check whether
Process monitoring—Real-time observa-
Quality control—Examine prototypes and
Research and development—Quantify
Electronic design—Circuit board analysis.
®
Technology fusing visual (visible
®
IR analysis and reporting
specific problems in equipment and systems.
Identify electrical and mechanical problems before they cause failure.
repairs have been performed correctly.
tion to ensure efficient and safe operations.
refine thermal management designs.
heat patterns to improve product designs.
Detailed specifications
Detailed Specifications
Fluke Ti55FT Fluke Ti50FT
Imaging performance
Field of view (FOV)* 23° horizontal x 17° vertical Spatial resolution (IFOV)* 1.30 mrad Min focus distance* 0.15 m (5.9 in) Thermal sensitivity (NETD) 0.05 °C at 30 °C (50 mK) 0.07 °C at 30 °C (70 mK) Detector data acquisition/image
frequency Focus SmartFocus; one finger continuous focus (manual) IR digital zoom 2x, 4x, 8x 2x Detector type 320 x 240 Focal Plane Array, Vanadium Oxide (VOx) Uncooled Microbolometer Spectral band 8 µm to 14 µm Digital image enhancement Automatic full time enhanced On camera operating modes Full thermal, full visual light or merged
Visible light camera 1280 x 1024 pixels, full color Visible light digital zoom 2x, 4x 2x
Temperature measurement
Calibrated temperature range -20 °C to 600 °C (-4 °F to 1112 °F)
in three ranges Range one =-20 °C to
100 °C (-4 °F to 212 °F) Range two = -20 °C to
350 °C (32 °F to 662 °F) Range three = 250 °C to 600 °C
(482 °F to 1112 °F)
Accuracy ± 2 °C or 2 % (whichever is greater) Measurement modes Centerpoint, center box (area min/max, average),
moveable spots/boxes, user defined field/text annotations, automatic hot and cold point detection, visible color alarm above and below
Emissivity correction 0.1 to 1.0 (0.01 increments)
Image presentation
Digital display 13 cm (5 in) diagonal large high-resolution digital display
LCD backlight Sunlight readable color LCD Video output RS170 EIA/NTSC or CCIR/PAL composite video Palettes Grayscale, grayscale inverted, blue red, high contrast, hot metal,
ironbow, amber, amber inverted
Optical lenses
54 mm telephoto lens High precision Germanium lens
Field of view (FOV): 9° horizontal x 6° vertical
Spatial resolution (IFOV): 0.47 mrad
Min focus distance: 0.6 m (1.97 ft)
10.5 mm wide angle lens High precision Germanium lens Field of view (FOV): 42° horizontal x 32° vertical
Spatial resolution (IFOV): 2.45 mrad
Min focus distance: 0.3 m (0.98 ft)
*Standard 20 mm Germanium lens
60 Hz/60 Hz
thermal-visual images.
Picture-in-Picture
-20 °C to 350 °C (-4 °F to 662 °F) in two ranges
Range one = -20 °C to 100 °C (-4 °F to 212 °F)
Range two = -20 °C to 350 °C (32 °F to 662 °F)
Centerpoint, center box (area min/max, average)