Atec TDS1000B, TDS2000B User Manual

Page 1
Digital Storage Oscilloscopes
TDS1000B Series • TDS2000B Series Data Sheet
Features & Benets
40 MHz, 60 MHz, 100 MHz, and 200 MHz Bandwidths
SampleRatesupto2GS/sRealTime
2 or 4 Channels
Color or Monochrome LCD Display
Removable Data Storage using the Front-panel USB Port
Advanced Triggers Including Pulse Width Trigger and Line-selectable Video Trigger
FFT Standard on All Models
11 Automatic Measurements
Multiple-language User Interface and Context-sensitive Help
Direct Print to all PictBridge®-compatible Printers through the USB Device Port
Lifetime Warranty*
®
and NI SignalExpress®PC Software
1
Applications
Design and Debug
Education and Training
Manufacturing Test and Quality Control
Service and Repair
*1Limitations apply. For terms and conditions, visit www.tektronix.com/lifetimewarranty.
TDS1000 Oscillo
Instant
The TDS1000B and TDS2000B Series digital storage oscilloscopes deliver an unbea you can afford.
B and TDS2000B Series
scopes
ly Productive. Incredibly Easy.
table combination of performance and ease of use, at a price
Page 2
Data Sheet
Quickly an
Affordable Digital Precision
d easily capture waveforms
With up to 200 MHz bandwidth and 2 GS/s maximum sample rate, no ot her color digital storage oscilloscope offers as much bandwidth and sample rate for the price. The TDS1000B and TDS2000B Series oscilloscopes provide accurate real-time acquisition up to their full bandwidth, the same record length at all time base settings, advanced triggers to isolate signals
st, and 11 standard automatic measurements on all models. Their
of intere Fast Fourier Transform (FFT) and waveform add, subtract, and multiply math functions allow you to analyze, characterize, and troubleshoot circuits.
Quick and Easy Waveform Capture
The simple user interface with classic analog-style controls makes these instruments easy to use, reducing learning time and increasing efciency.
ve features such as the Autoset Menu, Probe Check Wizard,
Innovati Context-sensitive Help Menu, and color LCD display (TDS2000B Series) optimize instrument setup and operation.
Flexible Data Transfer
With USB host and device ports which enable removable data storag e, seamless PC connectivity, and direct printing, no other color or monochr
ome digital storage oscilloscope offers as much exibility and ease
of data transfer for the price.
Simple Documentation and Analysis
Easily capture, save, and analyze measurement results with OpenChoice PC Communications Software. Simply pull screen images and waveform data into the standalone desktop application or directly into Microsoft
d Excel. To complement OpenChoice, National Instruments
Word an SignalExpress Tektronix Edition Software provides you w ith extended capabilities, including advanced analysis, remote oscilloscope control, and live waveform analysis. Alternatively, if you prefer not to use the PC, you
Conveniently use your USB ash drive to store screenshots and waveform data
Easily capture, save, and analyze measurement results with OpenChoice PC Communications Software
mply print your image directly to any PictBridge-compatible printer
can si using the USB device port.
Performance You Can Count On
Depend on Tektronix to provide you with performance you can count on. In addition to industry-leading service and support, every TDS10 00B and TDS2000B Series oscilloscope comes backed with a Lifetime Warranty* as standard.
*1Limitations apply. For terms and conditions, visit www.tektronix.com/lifetimewarranty.
1
2 www.tektronix.com
Page 3
Digital Storage Oscilloscopes — TDS1000B Series • TDS2000B Series
Characteristics
TDS1000B and TDS2000B Series Digital Storage Oscilloscopes
TDS1001B TDS1002B TDS1012B TDS2002B TDS2004B TDS2012B TDS2014B TDS2022B TDS2024B
Display (1/4 VGA LCD)
Bandwidth*
2
Channels External Trigger
Input Sample Rate on
Each Channel Record Leng
th
Vertical
n
Resolutio Vertical
Sensitivity DC Vertical
Accuracy Vertical Zoom Maximum Input
Voltage
on Range
Positi
idth Limit
Bandw Input Coupling AC, DC, GND on all models Input
ance
Imped Time Base
Range Time Base
Accuracy Horizontal
Zoom
I/O Interfaces
USB Ports Included on all models: 2 USB 2.0 ports
GPIB Optional
Nonvolatile Storage
Reference Waveform Display
Waveform Storage w/o USB Flash Drive
Maximum USB Flash Drive Size
Waveform Storage with USB Flash Drive
Setups w/o USB Flash Drive
Setups with USB Flash Drive
Screen Images with USB Flash Drive
Save All with USB Flash Drive
*2Bandwidth is 20 MHz at 2 mV/div, all models.
Mono Mono Mono
Color Color Color Color Color Color
40MHz 60MHz 100MHz 60MHz 60MHz 100MHz 100MHz 200MHz 200MHz
222242424
Included on all models
500 MS/s 1.0 GS/s 1.0 GS/s 1.0 GS/s 1.0 GS/s 1.0 GS/s 1.0 GS/s 2.0 GS/s 2.0 GS/s
2.5 K points
at all time bases on all models
8bits
2mVto5V/divonallmodelswithcalibratedne adjustment
+3% on all models
Vertically expand or compress a live or stopped waveform
300 V
CAT II; derated at 20 dB/decade above 100 kHz to 13 V
RMS
2mVto200mV/div+2V;>200mVto5V/div+50V
20 MHz for all models
1MΩ in parallel with 20 pF
5nsto50s/div 5nsto50s/div 5nsto50s/div 5nsto50s/div 5nsto50s/div 5nsto50s/div 5nsto50s/div
50 ppm
Horizontally expand or compress a live or stopped waveform
USB host port on front panel supports USB ash drives
USB device port on back of instrument supports connection to PC and all PictBridge-compatible printers
(2) 2 .5 K point reference waveforms
(2) 2.5 K point (2) 2.5 K point (2) 2.5 K point (2) 2.5 K point (4) 2.5 K point (2) 2.5 K point (4) 2.5 K point (2) 2.5 K point (4) 2.5 K point
2GB
96 or more reference waveforms per 8 MB
10 front-panel setups
4000 or more front-panel setups per 8 MB
128 or more screen images per 8 MB (the number of images depends on le format selected)
12 or more Save All operations per 8 MB
A single Save All operation creates 3 to 9 les (setup, image, plus one le for each displayed waveform)
AC at 3 MHz
p-p
2.5 ns to 50 s/div
2.5 ns to 50 s/div
www.tektronix.com 3
Page 4
Data Sheet
Acquisition Modes
Peak Detect – High-frequency and random-glitch capture. Captures glitches as
narrow as 12 ns (typical) using acquisition hardware at all time base settings from 5 μs/divto50s
Sample – Sampl Average – Wave Single Sequen
acquisition sequence at a time.
Roll Mode – At acquisition time base settings of >100 ms/div.
/div.
edataonly. form averaged, selectable: 4, 16, 64, 128.
ce –
Use the Single Sequence button to capture a single triggered
Tri gger System
Trig ge r Mo de s – Auto, Normal, Single Sequence.
Trigger Types
Edge (rising/falling) – Conventional level-driven trigger. Positive or negative slope on
any channel. Coupling selections: AC, DC, Noise Reject, HF Reject, LF Reject.
Video – Trigger on all lines or individual lines, odd/even or all elds from composite
video, or br
Pulse Widt
not equal to, a selectable time limitrangingfrom33nsto10s.
oadcast standards (NTSC, PAL, SECAM).
h(orGlitch)–
Trigger on a pulse width less than, greater than, equal to, or
Trigger Source
2-channel Models – CH1, CH2, Ext, Ext/5, AC Line. 4-channel Models – CH1,CH2,CH3,CH4,Ext,Ext/5,ACLine.
Trigger View
trigger signal while trigger view button is depressed.
Displays
Tri gger S
Provides a frequency readout of the trigger source.
ignal Frequency Readout
Cursors
Types – Amplitude, Time. Measurements – [Δ]T, 1[Δ]T (frequency), [Δ]V.
Autorange
Automatically adjust vertical and/or horizontal oscilloscope settings when probe is moved from p oint to point, or when the signal exhibits large changes.
Display Characteristics
Display –
Color models: ¼ VGA passive color LCD with color on black background with adjustable multilevel contrast. Monochrome models: ¼ VGA backlit passive LDC with adjustable multilevel contrast and inverse video selectable from front panel.
Interpolation – Sin(x)/x.
Display Types – Dots, vectors.
Persistence – Off,1s,2s,5s,innite.
Format – YT and XY.
Environmental and Safety
Temperature –
Operating: 0 to +50 ºC. Nonoperating: -40 to +71 ºC.
Humidity –
Operating and Nonoperating: Up to 80% RH at or below +40 ºC. Operating and Nonoperating: Up to 45% RH up to +50 ºC.
Altitude –
Operating and Nonoperating: Up to 3,000 m.
Electromagnetic Compatibility – Meets Directive 89/336/EEC, amended by
93/68/EEC, meets or exceed EN55011 Class A Radiated and Conducted Emissions; FCC 47 CFR, Part 15, Subpart B, Class A; Australian EMC Framework, demonstrated per Emission Standard AS/NZS 2064; Russian GOST EMC regulations.
Safety – UL610100-1:2003, CSA22.2 No. 61010-1:2003, EN61010-1:2001,
IEC61010-1:2001.
Automatic Waveform Measurements
Period, Frequency, +Width, -Width, Rise Time, Fall Time, Max, Min, Peak-to-Peak, Mean, Cycle RMS.
Waveform Math
Operators – Add, Subtract, Multiply, FFT. FFT – Windows, Hanning, Flat Top, Rectangular, 2048 sample points. Sources –
nnel models: CH1 - CH2, CH2 - CH1, CH1 + CH2, CH1 × CH2
2-cha 4-channel models: CH1 - CH2, CH2 - CH1, CH3 - CH4, CH4 - CH3, CH1 + CH2, CH3 + CH4, CH1 × CH2, CH3 × CH4
set Menu
Auto
Single-button, automatic setup of all channels for vertical, horizontal, and trigger systems, with undo Autoset.
Signal Type Autoset Menu Choices
Square Wave Single-cycle, Multicycle, Rising or Falling
Sine Wave Single-cycle, Multicycle, FFT Spectrum Video (NTSC, PAL, SECAM) Field: All, Odd, or Even
Edge
Line: All or Selectable Line Number
Physical Characteristics
Instrument
Dimensions
Width 326.3 12.85 Height 158.0 6.22 Depth 124.2 4.89
Weight kg lb.
rument Only
Inst
with accessories 2.2 4.9
Instrument Shipping
Package Dimensions mm in.
Width 476.2 18.75 Height 266.7 10.5 Depth 228.6 9.0
RM2000B Rackmount mm in.
Width 482.6 19.0 Height 177.8 7.0 Depth 108.0 4.25
mm
2.0 4.4
in.
4 www.tektronix.com
Page 5
Digital Storage Oscilloscopes — TDS1000B Series • TDS2000B Series
Ordering Information
TDS1001B: 40 MHz, 2 Ch, 500 MS/s, Monochrome DSO.
TDS1002B: 60 MHz, 2 Ch, 1 GS/s, Monochrome DSO.
TDS1012B: 100 MHz, 2 Ch, 1 GS/s, Monochrome DSO.
TDS2002B: 60MHz,2Ch,1GS/s,ColorDSO.
TDS2004B: 60MHz,4Ch,1GS/s,ColorDSO.
TDS2012B: 100MHz,2Ch,1GS/s,ColorDSO.
TDS2014B: 100MHz,4Ch,1GS/s,ColorDSO.
TDS2022B: 200MHz,2Ch,2GS/s,ColorDSO.
TDS2024B: 200MHz,4Ch,2GS/s,ColorDSO.
Standard Accessories
Passive Probes – 200 MHz (one pe
Power Cord – (Please specify plug option).
NIM/NIST – Traceable Certicate of Calibration.
Documentation – User Manual (Please specify preferred language option).
OpenChoice PC Communications Software – Enables fast and easy communication
between a Windows PC and the TDS1000B and TDS2000B Series using USB. Transfer and save settings, waveforms, measurements, and screen images.
National Instruments SignalExpress Tektronix Edition Interactive Measurement Software - Base Version –
optimized for the TDS1000B and TDS2000B Series. Enables you to instantly acquire, generate, analyze, compare, import, and save measurement data and signals using intuitive drag-and-drop user interface that does not require any programming. Standard TDS1000B and TDS2000B Series support for acquiring, controlling, viewing, and exporting your live signal. A 30-day trial period of the Professional Version provides additional signal processing, advance analysis, mixed signal, sweeping, limit testing, and user-dened step capabilities. Order SIGEXPTE for permanent Professional Version capability. Limited Lifetime Warranty* workmanship for a minimum of 10 years, excluding probes and accessories*
*3Lifetime is dened as ve years after Tektronix discontinues manufacturing the product, but the
warranty length shall be at least ten years from date of original purchase. Lifetime warranty is nontransferable, proof of original purchase is required. Limitations apply. For terms and conditions visit www.tektronix.com/lifetimewarranty.
International Power Plugs
Opt. A0 – North America power.
Opt. A1 – Universal EURO power.
Opt. A2 – United Kingdom power.
Opt. A3 – Australia power.
Opt. A5 – Switzerland power.
Opt. A6 – Japan power.
Opt. A10 – China power.
Opt. A11 – India power.
Opt. A99 – No power cord or AC adapter.
r channel).
A fully interactive measurement software environment
3
covering labor and parts for defects in materials and
4
.
User Manual Options
Opt. L0 – Englis Opt. L1 – French manual. Opt. L2 – Italian manual. Opt. L3 – Germa Opt. L4 – Spanish manual. Opt. L5 – Japanese manual. Opt. L6 – Portu Opt. L7 – Simple Chinese m anual. Opt. L8 – Standard Chinese manual. Opt. L9 – Kore Opt. L10 – Russian manual.
Translated front-panel overlays included with their respective user manuals.
Recommende
TEK-USB-488 – GPIB to USB converter. SIGEXPTE – National Instruments SignalExpress Tektronix Edition Interactive
Measurement Software - Professional Version.
AC2100 – So HCTEK4321 – Hard Plastic Carrying Case for Instrument (requires AC2100). RM2000B – Rackmount Kit. 071-1075­071-1828-xx – Service Manual - English Only. TNGTDS01 – Operator Training Kit - Extensive instructions and step-by-step lab
exercises provide education about the operation of TDS1000B and TDS2000B Series oscilloscopes. Kit includes self-paced CD-ROM-based manual and signal-source board.
174-4401
h manual.
n manual.
guese manual.
an manual.
d Accessories
ft Carrying Case for Instrument.
xx –
Programmer Manual - English Only.
-xx –
USB host to device cable, 3 feet long.
Recommended Probes
P2220 – 10 P6101B – 1x passive probe (15 MHz, 300 V P6015A – 1000x high-voltage passive probe (75 MHz). P5100 – 1 P5200 – High-voltage active differential probe (25 MHz). P6021 – 15 A, 60 MHz AC current probe. P6022 – A621 – 2000A,5to50kHzACcurrentprobe. A622 – 100 A, 100 kHz AC/DC current probe/BNC. TCP303 TCP305/TCPA300 – 50 A, 50 MHz AC/DC current probe/amplier. TCP312/TCPA300 – 30 A, 100 MHz AC/DC current probe/amplier. TCP40
Service Options*
Opt. C Opt. C5 – Calibration Service 5 Years. Opt. D1 – Calibration Data Report. Opt. D Opt. D5 – Calibration Data Report 5 Years (with Opt. C5). Opt. CA1 – Provides a single calibration event or coverage for the designated
calibration interval, whichever comes rst.
*4Probes and accessories are not covered by the oscilloscope warranty and Service Offerings. Refer to the
x to 1x Switchable Passive Probe (200 MHz when 10x is selected).
CAT II rating).
RMS
00x high-voltage passive probe (75 MHz).
6 A, 120 MHz AC current probe.
/TCPA300 –
4XL/TCPA400 –
3–
3–
datasheet of each probe and accessory model for its unique warranty and calibration terms.
15 A, 15 MHz AC/DC current probe/amplier.
500 A, 2 MHz AC/DC current probe/amplier.
4
Calibration Service 3 Years.
Calibration Data Report 3 Years (with Opt. C3).
www.tektronix.com 5
Page 6
Data Sheet
Service Offerings (available after purchase)
TDSxxxxB-CA1 – Provides a single calibration event or coverage for the designated
calibration interval, whichever comes rst.
The Complete Measurement Solution
The AFG3000 Series arbitrary function generator pairs with the TDS2000B and TDS1000B Series digital storage oscilloscopes to deliver the two elements of a complete measurement solution - stimulus and acquisition. This instrument combines the capabilities of a function generator with the power of an arbitrary waveform generator, offering the performance needed to accurately verify, validate, and characterize designs with ease and condence at a price you can afford.
The Tektronix Customer Service Advantage
You can trust Tektronix to offer unequalled engineering expertise and a customer-centric approach to ensure the optimal performance of your Tektronix products and maximize the lifetime value of your Tektronix investment. With service from Tektronix you get:
• Access to the source of product knowledge; unsurpassed technical expertise
• Your challenges solved by front-line technical experts, design engineering reinforcement, and online support tools
• Comprehensive and tho rough support provided worldwide , including software and rmware updates, data reports, and adjustments
•Efficiency and convenience; no hassle service from initial service call to turnaround and delivery
• Flexible repair and calibration service with access to the best on-call technical troubleshooting staff in the industry, with over 20 years of training per support engineer
• Customer-centric approach dedicated to serving your needs everyday with services designed to optimize your product performance, increase productivity and ROI by delivering a xed cost of ownership, and efcient management of service
Get checked by Tektronix. Visit www.tektronix.com/serviceandsupport.
6 www.tektronix.com
Product(s) are manufactured in ISO registered facilities.
Product(s) complies with IEEE Standard 488.1-1987, RS-232-C, and with Tektronix Standard Codes and Formats.
Page 7
Digital Storage Oscilloscopes — TDS1000B Series • TDS2000B Series
www.tektronix.com 7
Page 8
Data Sheet
Contact Tektronix:
ASEAN / Australa
Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777
Central East Eu
Mexico, Central/South America & Caribbean 52 (55) 54247900
rope, Ukraine, and the Baltics +41 52 675 3777
Central Europe & Greece +41 52 675 3777
Luxembourg +44 (0) 1344 392400
Asia, and North Africa +41 52 675 3777
Middle Eas t,
The N etherlands 090 02 021797
People’s Rep
United Kingdom & Ireland +44 (0) 1344 392400
For other areas contact Tektronix, Incat: 1 (503) 627-7111
ublic of China 86 (10) 6235 1230
Republic of
sia (65) 6356 3900
Austria +41 52 675 3777
Belgium 07 81 601
Brazil +55 (11) 40669400
Canada 1 (800) 661-5625
Denmark +4580881401
Finland +41526
France +33(0)169868181
Germany +49 (221) 94 77 400
Hong Kong (852
India (91) 80-42922600
Italy +39 (02) 25086 1
Japan 81 (3) 67
Poland +41 52 675 3777
Portugal 80 08 12370
Korea 82 (2) 6917-5000
Russia & CIS +7 (495) 7484900
South Africa +27 11 206 8360
Spain (+34)
Sweden 020 08 80371
Switzerland +41 52 675 3777
Tai wa n 886 (
USA 1 (800) 426-2200
75 3777
) 2585-6688
14-3010
Norway 800 16098
901 988 054
2) 2722-9622
Updated 30 October 2008
66
www.tektronix.com
For Further Information. Tektronix maintains a comprehensive, constantly expanding collection of application notes, technical briefs and other resources to help engineers working on the cutting edge of technology. Please visit www.tektronix.com
t © Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents,
Copyrigh
d pending. Information in this publication supersedes that in all previously published material.
issued an
tion and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of
Specica
x, Inc. All other trade names referenced are the service marks, trademarks, or registered trademarks
Tek tro ni
espective companies.
of their r
16 Jul 2009 3GW-19558-1