Atec SG User Manual

Sorensen SG Series
4–150 kW
Programmable Precision High Power DC Power Supply
High Power Density: up to 15 kW in 3U, 30 kW in a 6U chassis
• Wide Voltage Range: 0-10V up to 0-1000V, from 4 to 30 kW
• Fast Load Transient Response: Protection from undesired voltage excursions
• Low Ripple and Noise
• Hardware Trigger (Ethernet Option)
• Parallelable up to 150 kW
• Sequencing: Free system controller & speed up test
• Low audible noise: Temperature controlled variable speed fans
The Sorensen SG Series (hereafter SG Series) represents the next generation of high power programmable DC power supplies. The SG Series is designed for exceptional load transient response, low noise and the highest power density in the industry. With a full 15 kW available down to 20VDC output in a 3U package the SG leads the industry in power density. The power density is enhanced by a stylish front air intake allowing supplies to be stacked without any required clearance between units.
At the heart of the SG series is a 5 kW power module. Depending on the output voltage, one to six modules can be congured in a single chassis to deliver 5 kW to 30 kW of power. Combinations of these chassis can then be easily paralleled to achieve power levels up to 150 kW. Paralleled units operate like one single supply providing total system current. Available in two control versions, the SGA has basic analog controls, while the SGI provides intelligent control features.
SGI: Advanced Intelligent Control
(Sorensen General purpose Intelligent) The SGI combines onboard intelligent controls with the outstanding power electronics common to all SG family supplies. These controls enable sophisticated sequencing, constant power mode and save/recall of instrument settings. Looping of sequences makes the SGI ideal for repetitive testing. An impressive vacuum uorescent graphical display in eight languages, context sensitive “soft” keys and front panel keyboard simplify programming of the SGI.
SGA: Outstanding Value - Analog Control
(Sorensen General purpose Analog) The SGA, with its industry leading performance, is available for customers requiring simple front panel analog controls or external control. With the same high performance power electronics as the SGI, the SGA provides essential features like 10- turn potentiometers for setting voltage and current, 3 ½ digit LED readout plus front panel over-voltage protection (OVP) preview/adjustment and reset.
10–1000 V
5–6000 A
208 400 480
858.458.0223
sales@ProgrammablePower.com
AMETEK Programmable Power
9250 Brown Deer Road San Diego, CA 92121-2267 USA
05012013
77
SG Series : Product Specications
Common
Remote Sense Terminals are provided to sense output voltage at point of load. Maximum line drop 5% of rated voltage per line for 40-100V models,
Parallel Operation Up to 5 units may be paralleled for additional current within the power supply single-unit specications, with exception of the
Series Operation Up to 2 units (see Output Float Voltage)
Input
Nominal Voltage
3 phase, 3 wire + ground
Frequency 47 – 63Hz , 400Hz ( 400Hz @ 208VAC, for 6U units is optional modication and does not carry CE, UL or CSA markings )
Power Factor >0.9 typical for 10V - 30V, 50V, 1000V and other models with optional “PF” modication.
Protection ( typical ) ½ cycle ride-though , typical, on all three phases, 3 cycle ride through on single phase; missing phase shutdown
Programming & Read-back Specications ( with sense wires used )
Accuracy Resolution Accuracy Resolution
SGA: +/- (0.5%fs + 1 digit) SGI (40-1000V) +/- 0.1% of
voltage at full scale
SGI (40-1000V) +/- 0.4% of
Front panel Display
Remote Analog
Interface
Remote Digital
Interface
OVP +/- 1% of full scale
User I/O Disconnect & Polarity-reversal relay control ( Only available with Ethernet Option )
Software IVI & CVI drivers available under SUPPORT at: www.ProgrammablePower.com
current at full scale
SGI (10-30V) 0.1% of set point
+0.1% of voltage rating
SGI (10-30V) 0.1% of set point
+0.4% of current rating
Voltage +/-0.25% of full scale Current (40-1000V) 0.8% of full
scale , (10-30V) 1.0% of full scale
Voltage: +/- 0.1% of full scale, Current: +/- 0.4% of full scale
Physical 3U Models (10V-30V) 3U Models (40V-1000V) 6U Models (60V-600V)
Width 19.00 in (48.3 cm) 19.00 in (48.3 cm) 19.00 in (48.3 cm)
Depth 27.18 in (69.0 cm) 26.4 in (67.1 cm) 27.06 in (68.8 cm)
Height 5.25 in (13.3 cm) 5.25 in (13.3 cm) 10.5 in (26.7 cm)
Weight (4kW, 10V 15V) ≈<65 lbs (29 kg)
Shipping Weight Contact factory for more product & shipping weights
line drop 1V of rated voltage per line for 10-20V models, 1.5V for 30V models, 2% of rated voltage per line for models 160V and greater. (Greater line drop is allowed, but output regulation specications no longer apply).
DC output current set accuracy. Additional paralleled SG units will add 0.3% inaccuracy per unit. To parallel more than 5 units, contact factory.
208/220 VAC (operating range 187 - 242 VAC) 380/400 VAC (operating range 342 - 440 VAC) 440/480 VAC (operating range 396 - 528 VAC)
>0.75 typical for 208/220 VAC input (40V, 60V - 800V models, 0.9 available with modication “PF”) >0.72 typical for 380/480 VAC input (40V, 60V - 800V models, 0.9 available with modication “PF”) >0.69 typical for 440/480 VAC input (40V, 60V - 800V models, 0.9 available with modication “PF”)
( 800V model 6.4 msec on all 3 phases )
Programming Read-Back / Monitoring
SGA: +/- (0.5%fs + 1 digit) SGI, Voltage: +/- 0.1% of full scale
SGA: 3.5 digits SGI: 4.0 digits
NA
+/-0.002% of
full scale
+/-0.002% of
full scale
(5kW, 20V 30V) ≈<65 lbs (29 kg) (8kW, 10V 15V) ≈<85 lbs (39 kg) (10kW, 20V 30V) ≈<85 lbs (39 kg) (12kW, 10V 15V) ≈<110 lbs (50 kg) (15kW, 20V 30V) ≈<110 lbs (50 kg)
SGI, Current: +/- 0.4% of full scale
SGI (10-30V) 0.1% of actual
+0.15% voltage rating
(40-1000V) +/-1.0% of full scale
(10-30V) +/-0.5% of full scale
Voltage: +/- 0.1% of full scale Current: +/- 0.4% of full scale
(5kW) ≈ 40 lbs (18 kg) (10kW) ≈ 60 lbs (27 kg) (15kW) ≈ 80 lbs (36 kg)
SGA: 3.5 digits SGI: 4.0 digits
NA
+/-0.002% of
full scale
Knob control & Display read-back
25-pin D-sub connector (0~5 V or 0~10 V)
RS-232C (Standard on SGI), Optional
IEEE-488.2 and Optional LXI Compliant 10/100 base-T Ethernet (see Options)
Programming range: 5-110% Congured
from front panel, remote analog or via optional digital inputs
Digital 10-pin Molex type connector See www.programmablepower.com
(20kW) ≈ 120 lbs (54 kg) (25kW) ≈ 140 lbs (64 kg) (30kW) ≈ 160 lbs (73 kg)
78
www.ProgrammablePower.com
SG Series : Product Specications
4-150 kW
Output
Ripple & Noise (Voltage Mode, Typical) See Output: Voltage & Current Ranges Chart below. Ripple and noise specied at full load, nominal AC input. Noise measured with 6
Ripple (Current Mode) <+/- 0.04% of full scale rms current
Output Voltage Rise Time (40-1000V) ≈< 100 ms 10-90% of full scale typical - full resistive load (Contact factory for model specic slew rates)
Output Voltage Rise Time (10-30V)
Output Voltage Fall Time (10-30V)
Output Current Rise Time (10-30V)
Output Current Fall Time (10-30V)
DC Current Slew Rate 45A / ms typical - resistive load
Line Regulation ( with sense wires used ) (±10% of nominal AC input, constant load)
Load Regulation (with sense wires used) (no load to full load, nominal AC input)
Load Transient Response Recovers within 1ms to +/-0.75% of full-scale of steadystate output for a 50% to 100% or 100% to 50% load change
Efciency 87% typical at nominal line and max load
Stability ±0.05% of set point after 30 minute warm-up and over 8 hours at xed line, load and temperature, typical
Temperature Coefcient 0.02%/ C of maximum output voltage rating for voltage set point, typical
Output Float Voltage Negative terminal within +/- 300 V of chassis potential. ( We recommend the use of optional isolated analog Interface (IAI). )
ft. cable, 1μf at load
Rise Time, ms, max Condition
10 Measured from 10% to 90% of the output voltage change - resistive load, typical
Fall Time, ms max Condition
No Load 1 100% CC Load 100% CR Load Measured from 90% to 10% of the output voltage change. - resistive
50 10 10
Rise Time, ms max Condition
20 Measured from 10% to 90% of the output current change - resistive load, typical
Fall Time, ms max Condition
10 Measured from 90% to 10% of the output current change - resistive load, typical
Voltage Mode: +/- 0.01% of full scale (40-800V) Current Mode: +/- 0.05% of full scale (40-800V) Voltage Mode and Current Mode: +/- 0.05% of full scale (10-30V)
Voltage Mode: +/- 0.02% of full scale (40-800V) Current Mode: +/- 0.1% of full scale Voltage Mode: +/- 0.05% of full scale (10-30V)
0.03%/ C of maximum output current rating for current set point, typical
Supplies in “series” have a system current limit of the lowest current supply in the system.
load, typical
Output: Voltage and Current Ranges
3U 6U Ripple & Noise
Power 4/5 kW 8/10 kW 12/15 kW 16/20 kW 20/25 kW 24/30 kW
Voltage Current
10 400 800 1200 1600* 2000* 2400* 20 mV 50 mV
15 267 534 801 1068* 1335* 1602* 20 mV 50 mV
20 250 500 750 1000* 1250* 1500* 20 mV 60 mV
30 167 334 501 668* 835* 1002* 20 mV 60 mV
40 125 250 375 500* 625* 750* 20 mV 75 mV
50 100 200 300 400* 500* 600* 20 mV 75 mV
60 83 167 250 333 417 500 20 mV 75 mV
80 63 125 188 250 313 375 20 mV 100 mV
100 50 100 150 200 250 300 20 mV 100 mV
160 31 63 94 125 156 188 25 mV 150 mV
200 25 50 75 100 125 150 25 mV 175 mV
250 20 40 60 80 100 120 30 mV 200 mV
330 15 30 45 61 76 91 30 mV 200 mV
400 12 25 38 50 63 75 40 mV 300 mV
600 8 17 25 33 42 50 60 mV 350 mV
800 6.2 12.5 18.7 25* 31.2* 37.5* 80 mV 500 mV
1000 5 10 15 20* 25* 30* 100 mV 650 mV
* By way of p aralle ling 3U supplies
rms
(20 Hz-300 kHz)
p-p
(20 Hz-20 MHz)
858.458.0223
sales@ProgrammablePower.com
79
SG Series : Product Diagram
3U Case (10-30V)
147
5.80
59
2.33
41
1.63
Top View
1.69
631
24.84
43
483
19.00
Front View
429
16.90
62
2.45
Rear View
41
1.62
3U Case (40-1000V)
Top View
6U Case (60-600V)
17.03
1.07
4.00
27.18
27.30
23.90 (607)
26.40 (671)
2.50 (64)
(3.05)
1.04
.12
23.03
19.00 (483)
Front View
16.90
(429.3)
Rear View
Front View
19.00
16.90
(429.3)
5.22
(132)
10.47
80
1.62
Top View
Rear View
www.ProgrammablePower.com
SG Series
4–150 kW
Advanced Power Simulation
SGI model provides constant power mode allowing independent setting of the max voltage, current and power
SGI / SGA Comparison Chart
Feature SGA SGI
Modular Design
Fast Load Transient
Parallelable
Analog & Digital Summing Optional
Direct Front Panel V/I Control
3½ Digit LED Readout
Graphics Display
Sequencing
Save/Recall Setups
System Power Readouts
Constant Power Mode
IEEE-488.2/RS-232C Optional RS-232C Std, IEEE-488.2 Optional
LXI Class C Ethernet/ RS-232 Optional RS-232C Std, Ethernet Optional
Front Panel Dust Filter Optional (3U unit only) Optional (3U unit only)
Environmental
Operating Temperature 0 to 50º C
Storage Temperature -25º C to 65º C
Humidity Range Relative humidity up to 95% non-condensing, 0º C – 50º C
Altitude Operating full power available up to 5,000 ft. (~1,500 m), derate 10% of full power for every 1,000 feet higher; non-operating
Cooling Front and side air inlet, rear exhaust. Temperature controlled, variable speed fans. Units may be stacked without spacing.
Regulatory Certied to UL/CSA 61010 and IEC/EN 61010-1 by a NRTL, CE Compliant, Semi-F47 Compliant.
Front Panel Dust Filter 30 PPI (Pores Per Inch) - must ensure adequate airow and / or derate max. temperature. 3U unit only.
to 40,000 ft. (~12,000 m)
LVD Categories: Installation Category II: Pollution Degree 2; Class II Equipment: for Indoor Use Only, back panel not user accessible
(see user manual for installation instructions)
EMC Directive, EN 61326:1998
858.458.0223
sales@ProgrammablePower.com
81
SG Series
-ASG
Control Designation
100
Voltage
1A AA
Remote Control Options
Process Options
100X
Current
C
Input Voltage Options
A = Analog I = Intelligent
4 - 15kW = “ X ”
20 - 30kW = “ / ”
AA
Modifications
(For units with greater than 3 digits, Voltage/Current is represented in numeric format, e.g., above “100” represents 100A.
For units at 1000 and above, the voltage is represented by the format “XKX”, e.g, 1K2 = 1200V and 1K0 = 1000V)
Options and Accessories
Control Options
Input Options
Remote Control Options 0A: No Option
Process Options AA: No option
Modications AJ: Front panel dust lter - factory installed - 3U unit only
Accessories 890-453-03: Paralleling Cable (for up to 5 units, requires one cable per unit placed in parallel)
Contact factory for other combinations
A: Analog I: Intelligent
C: Input Voltage 187 / 242VAC, 3 Phase D: Input Voltage 342 / 440VAC, 3 Phase E: Input Voltage 396 / 528VAC, 3 Phase
1A: IEEE-488.2 + RS-232C (Note: SGI comes standard with RS-232C) 1C: Ethernet + RS-232C 1D: Isolated Analog Control 1E: Shaft Locks (SGA series only) 2A: Combined Options 1A+1D 2C: Combined Options 1A+1E (SGA Only) 2G: Combined Options 1C+1D 2H: Combined Options 1C+1E (SGA Only) 2J: Combined Options 1D+1E (SGA Only) 3C: Combined Options 1A+1D+1E (SGA Only) 3G: Combined Options 1C+1D+1E (SGA Only)
AB: Certicate of Calibration to ANSI / NCSL Z540-1 (includes Test Data)