Atec SFA User Manual

Sorensen SFA Series
5–150 kW
High Slew Rate Current Source
3U 6U
Power
Voltage Maximum Current
60 83 167 250 333 417 500 100 50 100 150 200 250 300 160 31 63 94 125 156 188
Specications (at nominal AC line and 25ºC)
Output Slew Rate (10-90% resistive load) 250A/ms (400A/ms typical) rise, 200A/ms typical fall; 160V model 87A/ms/5kW (145A/ms/5kW typical), 60A/ms, typical, fall Control Mode Current Control Only Front Panel Meter Accuracy Voltage ±0.5% of full-scale + 1 digit, Current ±0.5% of full-scale + 1 digit Load Regulation (no load to full load, nominal AC input) Current 0.1% of rated output current Line Regulation (±10% of nominal AC input) Current 0.05% of rated output current Current Ripple 1% p-p of full-scale current Transient Response Output current recovers to within 1% of current setpoint within 1ms for a 10 to 100% or 100% to 10% step load change Current Overshoot Maximum 8% of full-scale for 0 to 100% change into a resistive load Output Capacitance 60V Models <10 µF / 5 kW, 100/160V Models 3 µF / 5 kW Stability ±0.05% of setpoint after 8–hr. warm-up at xed line, load, and temperature using remote sense Power Factor >0.9 typical for 208/220VAC input, >0.78 typical for 380/400VAC input, >0.7 typical for 440/480VAC input Remote Analog Control Current Setpoint Accuracy, ±0.8% of full-scale output; Overcurrent Protection, ±1% of full-scale output;
Efciency 87% typical at full load, nominal line Remote Control/Monitor On/Off control via contact closure, 6-120 VDC or 12-240VAC, and TTL or CMOS switch, current monitor, OCP limit set,
Overvoltage Protection Fixed at approximately 110% of the rating compliance voltage. Reset requires cycling the front panel standby power switch off/on Ethernet Control (optional) LXI compliant 10/100 Base T Ethernet remote control with web server for direct control of power supply via web browser. Isolated Analog Control (optional) Input to Output Isolation: 500 V Compliant with max. terminal oat voltage. Recommended operation under SELV normal conditions. Regulatory Certied to UL/CSA 61010 and IEC/EN 61010-1, CE Compliant (LVD and EMC Directives), Input power options Input Power Conguration 3–phase, 3–wire plus ground. Not phase, rotation sensitive. Neutral not used. Input Power Voltage Selection 208/220 VAC±10%, 47 to 63 Hz, 380/400 VAC±10%, 47 to 63 Hz, 440/480 VAC±10%, 47 to 63 Hz
Environmental
Ambient Operating Temperature 0 to 50°C Storage Temperature -25 to 65°C Temperature Coefcient Current Setpoint 0.03%/°C of rated current Cooling Internal Fans. Zero clearance stacking Humidity 0 to 90% at 40°C; 0 to 50% at 25°C, non-condensing Altitude Full power at 5,000 feet, 10% derating of full power for every 1,000 feet above 5,000 feet
Physical
5 to 15 kW in 3U 19.00in W x 25.12in D x 5.25inH; 80 lbs., (48.3cm W x 63.8cm D x 13.3cm H; 36 kg) 20 - 30 kW in 6U 19.00in W x 25.12in Dx 10.5in x H; 160 lbs., (48.3cm W x 63.8cm D x 36.7cm H; 73 kg)
Accessories
Modications AJ: Front panel dust lter - factory installed - 3U unit only K550212-01 / 5550568-01 3U Rack Slides (for 5kW, 10kW and 15kW models) / Front panel dust lter - eld installation kit - 3U unit only K550213-01 / 9550589-01 6U Rack Slides (for 20kW, 25kW and 30kW models) / AC input cover - 3U unit only
5 kW 10 kW 15 kW 20 kW 25 kW 30 kW
(parallel for higher current. )
Resistive Control, 0–5kΩ = 0-100% Current; Voltage Control, 0–5 or 0–10 VDC = 0-100% Current; Overcurrent Protection, 0–5.5 VDC = 0-110%
summary fault status
60–160 V
31–2500 A
208 400 480
858.458.0223
sales@ProgrammablePower.com
83
Notes
84