Atec Sentry50 User Manual

Sentry Series 50
USES:
• Production Testing of Appliances, Instruments and Information Technology Equipment with 3 Prong Power Cords
• Transformer Electrical Safety Testing
• Electric Motor Safety Testing
• Testing Electronic Components
FEATURES:
• Adjustable Output Current from 1A to 30A AC
• Adjustable High and Low Resistance Limits
• Adjustable No-Load Voltage Limit
• Current, Resistance and Voltage Display
• Zero Offset of Lead Resistance
• Programmable Test Time
• 4 terminal Kelvin Connection
• Under Test Warning Indicator
• Setup Storage
• Remote Control
• Built-in Calibration Software
• Beeper On/Off
Introduction
The Sentry 50 provides high current testing of ground continuity between chassis and power cord ground on a wide variety of electrical products and appliances. The unit is designed for maximum flexibility and operator convenience in mind. The Sentry 50 is ideal for Electrical Safety Compliance Testing in a variety of environments.
Description
Wide Test Current Range User programmable output current, 1A to 30A AC in
0.01A steps, provides extensive coverage for testing to UL, CSA, VDE, IEC and other agency safety requirements.
Programmable High and Low Resistance Limits A resistance measure-
ment range from 0.1mto 510mand user programmable high and low resistance lim­its with pass/fail indication.
Remote ControlCan be incorporated into an automated manufacturing environment
with remote start and Go/NoGo results output through the rear panel PLC interface.
Connection to Sentry 10 through 35 AC/DC Hipot TestersThe Sentry
50 can be used alone or connected to a Sentry 10 - 35 for complete product testing with the push of one button. When the Sentry 50 has completed a continuity test, with pass indication, it can remotely start the Sentry 10 - 35 for a Hipot test in sequence.
Easy to Use The simple front panel of the Sentry 50 requires less effort to operate.
Digital display and user friendly control allows test parameters and limits to be set easily without the high current activated. The instrument can be put on line fast, providing use­ful measurements by operators with little to no training.
Built-in Calibration via Software Front panel display of an operator prompted
calibration routine makes for no internal adjustments.
1-800-253-1230
Fax 1-978-461-4295
Intl. 1-978-461-2100
For more information about special purchase,
rent & lease options, call
For more detailed specifications, visit
www.quadtech.com
High Current Ground Bond Tester
HIPOT • LCR METERS • MEGOHMMETERS • MILLIOHMMETERS • DECADES • STANDARDS
Sentry 50
Output Current: Range: 3.00A to 30.00A AC, Setting
0.01A/step Useable down to 1.00A Accuracy: +/- (1% of setting + 0.3A)
+/- (2% of reading + 5 counts)
Frequency: 50 or 60 Hz
Voltage Limit: Range: 6.0 to 15VAC, Setting 0.01V/step Resistance: Range: 0.1m- 510.0m, 4 digits,
Hi/Lo limits Accuracy: +/- (1% of reading + 5 counts)
Offset Function: 0 to 100moffset, user selected Test Time: 0.1 - 999sec (+/-20ms) for I < 25A AC
0.1 - 60sec (+/-20ms) for I 25A AC setting 0.1sec < 100sec and 1 sec 100sec continuous operation mode
Remote Control: Remote Start, Stop, Interlock, Pass/Fail
Output via 9-Pin D series connector and terminal strip Start/Stop/Interlock: active low Pass/Fail Output: via relays, 115V AC 300mA
Mechanical: Bench mount with carry handle Dimensions: (w x h x d):11x4x14 in
(270x100x350mm)
Weight: 25 lbs (12kg)
Shipping: 30 lbs (14kg)
Environmental: Meets MIL-T-28800E, Type 3, Class 5
Operating: 0 to + 40° C Humidity: <75% Storage: - 10 to + 60° C Warm-up Time: 1minute
Power: • 90 - 130V AC • 50 or 60Hz
• 200 - 250V AC • 300W max
Sentry 50 Ground Bond Tester
Includes:
150285 Instruction Manual 700070 Power Cable G15 Ground Continuity Lead Set Calibration Certificate Traceable to NIST Fuse
Optional Accessories:
Calibration Data S05 Foot Switch S15 Interconnection Cable to
S10-S35 S16 Rack Mount Kit G13 Corded Product Adapter (115V)
G14 Power Entry Adapter G15 GC lead set (std w/unit) G16 International Power Strip G25 Corded Product Adapter
(240V)
Ordering Information
Product Specifications
510m
Resistance
210m
34m
3A
30A
Current
Specification Range
3.4m
PN030075/A2
(See Figure Above)
For more detailed specifications, visit www.quadtech.com • For more information about special purchase, rent & lease options, call
1-800-253-1230 Fax 1-978-461-4295 Intl. 1-978-461-2100
5 Clock Tower Place, 210 East, Maynard, MA 01754