Sorensen HPD Series
300 W
300 Watt DC Power Supply with Near-Linear Performance
• Low noise and ripple
• Excellent line/load regulation
• Constant voltage or constant current operation
with automatic crossover and mode indication
• Current limit
• Front and rear outputs
• Remote sense
• LabVIEW® and LabWindows® drivers
The Sorensen High Power Density (HPD) Series
provides 300 watts of reliable DC power in a
quarter-rack wide unit. The HPD Series power
supplies are ideal for benchtop, ATE and OEM
applications where a wide adjustment of output
voltage or current is required in a compact unit.
The HPD series uses switch-mode technology
combined with linear post regulation to provide
performance comparable to an all-linear design.
The HPD series features excellent line and load
regulation with low noise and good transient
response. The series is available in a single unit for
benchtop use. For systems applications, multiple
units can be rack-mounted in congurations of
up to four independent 300-watt outputs.
15–60 V
5–20 A
115 230
858.458.0223
sales@ProgrammablePower.com
Distributed by:
www.SignalTestInc.com
1529 Santiago Ridge Way
San Diego, CA 92154 USA.
Sales@SignalTestInc.com
107

HPD Series : Product Specications
1
Output : Voltage and Current
Models 15-20 30-10 60-5
Output Ratings
Output Voltage 0-15 V 0-30 V 0-60 V
Output Current 0-20 A 0-10 A 0-5 A
Output Power 300 W 300 W 300 W
Line Regulation
Voltage (0.01% of Vmax + 2 mV) 3.5 mV 5 mV 8 mV
Current (0.05% of Imax + 2 mA) 12 mA 7 mA 4.5 mA
Load Regulation
Voltage (0.01% of Vmax + 2 mV) 3.5 mV 5 mV 8 mV
Current (0.05% of Imax + 2 mA) 12 mA 7 mA 4.5 mA
Meter Accuracy
Voltage (1% of Vmax + 1 count) 250 mV 400 mV 700 mV
Current (1% of Imax + 1 count) 300 mA 200 mA 60 mA
Output Noise (90-20 MHz)
Voltage (p-p) (0-20 MHz) rear panel 75 mV 75 mV 100 mV
Voltage (p-p) (0-20 MHz) front panel 100 mV 100 mV 180 mV
Output Ripple
Voltage rms, rear panel 5 mV 5 mV 5 mV
Voltage rms, front panel 10 mV 10 mV 10 mV
Drift (8 hours)
Voltage (0.02% of Vmax) 3 mV 6 mV 12 mV
Current (0.08% of Imax) 16 mA 8 mA 4 mA
Temperature Coefcient
Voltage (0.015% of Vmax/°C) 2.25 mV 4.5 mV 9 mV
Current (0.02% of Imax/°C) 4 mA 2 mA 1 mA
HPD 300 W Internal Interface Specications with RS-232 or GPIB Interface Installed
Models 15-20 30-10 60-5
Program Accuracy
Voltage (mV) 60 + 0.1% 70 + 0.1% 90 + 0.12%
Current (mA) 75 + 0.12% 50 + 0.12% 25 + 0.1%
OVP (mV) 1500 3000 6000
Readback Accuracy
Voltage (mV) 45 + 0.3% 90 + 0.3% 175 + 0.3%
Current (mA) 75 + 0.12% 40 + 0.12% 25 + 0.1%
2
3
4
5
1,6
108
Specications subject to change without notice.
1. Specications indicate typical performance at 25°C ± 5°C, nominal line input of 120 Vac.
2. For input voltage variation over the AC input voltage range, with constant rated load.
3. For 0-100% load variation, with constant nominal line voltage.
4. Maximum drift over 8 hours with constant line, load, and temperature, after 60-minute warm-up.
5. Change in output per °C change in ambient temperature, with constant line and load.
6. Apply accuracy specications according to the following voltage program accuracy example: Set a model 15-20 power supply to 10 V. The expected result will be within the
range of 10 V ± 60 mV ± 0.1% of the set voltage of 10 V.
www.ProgrammablePower.com

HPD Series : Product Specications
1
300 W
Input
Operational AC Input Voltage Single unit: 104-127 Vac at 6 Arms; 47-63 Hz
General
Switching Frequency 100 kHz (nominal)
Voltage Mode Transient Response Time < 500 μs recovery to 50 mV band for ±50% load change in the range of 25% to 100% of the rated load
Front Panel Voltage and Current Control 10-turn voltage and 1-turn current potentiometers (10-turn current optional)
Front Panel Voltage Control Resolution 0.02% of maximum voltage
AC Input Connector Type EC 320 connector
Approvals CE-marked units meet: EN61010-1, EN61000-6-2 and EN61000-6-4; CSA C/US certied to UL61010-1B and CSA C22.2 No 1010.1;
Meets USA EMC standard: FCC, part 15B, Class A; Meets Canadian EMC standard: ICES-001, Class A.
Analog Programming (with optional APG interface installed)
Remote On/Off and Interlock 2 to 25 Vdc high. <0.8 Vdc low. User-selectable.
Remote Analog Programming Option 0-10 Vdc for 0-100% of rated voltage or current ±1.0%, 0-10kΩ for 0-100% of rated voltage or current ±1.0%
Remote Monitoring 0-10 Vdc for 0-100% or rated voltage or current ±1.0%
Over Voltage Protection Trip Range 3 V to full output ±10%
Tracking Accuracy ±1% for series operation
Environmental
Operating Temperature 0 to 30°C for full rated output. Above 30°C, derate output linearly to zero at 70°C.
Storage Temperature - 55 to 85°C
Humidity Range 0 to 80% RH, non-condensing
Physical
Dimensions Width: 4.2” (109.2 mm)
Weight Approximately 7.7 lb (3.5 kg)
Height: 5.2” (134.7 mm)
Depth: 11.7” (297 mm)
858.458.0223
sales@ProgrammablePower.com
109

HPD Series : Technical Diagram
Top
Front
Optional Carrying Handle
12.31
(312)
Right Side
110
Back
www.ProgrammablePower.com

HPD 15
Series
Voltage
20
Current
(XXX)
Options
HPD Series
Model Number Description
Options and Accessories
MGA * GPIB Interface card
MRA * RS-232 Interface card
MAA * Analog programming interface card
M2S Switch selectable input 110 Vac or 220 Vac
M11 10-turn current potentiometer
M13A Locking knobs for front panel controls
RM-XPDG-2 19-inch Rack Mount Kit for up to four HPD, XPD, XEL or XT power supplies
M2 AC Input Option - 200-250 Vac Input (50/60 Hz)