Atec HPD User Manual

Sorensen HPD Series
300 W
300 Watt DC Power Supply with Near-Linear Performance
• Low noise and ripple
• Excellent line/load regulation
• Constant voltage or constant current operation with automatic crossover and mode indication
• Front and rear outputs
• Remote sense
• LabVIEW® and LabWindows® drivers
The Sorensen High Power Density (HPD) Series provides 300 watts of reliable DC power in a quarter-rack wide unit. The HPD Series power supplies are ideal for benchtop, ATE and OEM applications where a wide adjustment of output voltage or current is required in a compact unit.
The HPD series uses switch-mode technology combined with linear post regulation to provide performance comparable to an all-linear design. The HPD series features excellent line and load regulation with low noise and good transient response. The series is available in a single unit for benchtop use. For systems applications, multiple units can be rack-mounted in congurations of up to four independent 300-watt outputs.
15–60 V
5–20 A
115 230
858.458.0223
sales@ProgrammablePower.com
Distributed by: www.SignalTestInc.com 1529 Santiago Ridge Way San Diego, CA 92154 USA. Sales@SignalTestInc.com
107
HPD Series : Product Specications
1
Output : Voltage and Current
Models 15-20 30-10 60-5
Output Ratings
Output Voltage 0-15 V 0-30 V 0-60 V
Output Current 0-20 A 0-10 A 0-5 A
Output Power 300 W 300 W 300 W
Line Regulation
Voltage (0.01% of Vmax + 2 mV) 3.5 mV 5 mV 8 mV
Current (0.05% of Imax + 2 mA) 12 mA 7 mA 4.5 mA
Load Regulation
Voltage (0.01% of Vmax + 2 mV) 3.5 mV 5 mV 8 mV
Current (0.05% of Imax + 2 mA) 12 mA 7 mA 4.5 mA
Meter Accuracy
Voltage (1% of Vmax + 1 count) 250 mV 400 mV 700 mV
Current (1% of Imax + 1 count) 300 mA 200 mA 60 mA
Output Noise (90-20 MHz)
Voltage (p-p) (0-20 MHz) rear panel 75 mV 75 mV 100 mV
Voltage (p-p) (0-20 MHz) front panel 100 mV 100 mV 180 mV
Output Ripple
Voltage rms, rear panel 5 mV 5 mV 5 mV
Voltage rms, front panel 10 mV 10 mV 10 mV
Drift (8 hours)
Voltage (0.02% of Vmax) 3 mV 6 mV 12 mV
Current (0.08% of Imax) 16 mA 8 mA 4 mA
Temperature Coefcient
Voltage (0.015% of Vmax/°C) 2.25 mV 4.5 mV 9 mV
Current (0.02% of Imax/°C) 4 mA 2 mA 1 mA
HPD 300 W Internal Interface Specications with RS-232 or GPIB Interface Installed
Models 15-20 30-10 60-5
Program Accuracy
Voltage (mV) 60 + 0.1% 70 + 0.1% 90 + 0.12%
Current (mA) 75 + 0.12% 50 + 0.12% 25 + 0.1%
OVP (mV) 1500 3000 6000
Readback Accuracy
Voltage (mV) 45 + 0.3% 90 + 0.3% 175 + 0.3%
Current (mA) 75 + 0.12% 40 + 0.12% 25 + 0.1%
2
3
4
5
1,6
108
Specications subject to change without notice.
1. Specications indicate typical performance at 25°C ± 5°C, nominal line input of 120 Vac.
2. For input voltage variation over the AC input voltage range, with constant rated load.
3. For 0-100% load variation, with constant nominal line voltage.
4. Maximum drift over 8 hours with constant line, load, and temperature, after 60-minute warm-up.
5. Change in output per °C change in ambient temperature, with constant line and load.
6. Apply accuracy specications according to the following voltage program accuracy example: Set a model 15-20 power supply to 10 V. The expected result will be within the range of 10 V ± 60 mV ± 0.1% of the set voltage of 10 V.
www.ProgrammablePower.com