Atec Hioki-8847 User Manual

For the fi eld Professional
Isolated inputs for all channels enhance measurement safety by letting you record differing electric potential objects simultaneously
Sturdy construction designed for use in the fi eld
Tough body and strong enclosure provide superior resistance to shocks, falls, and
Note: Using in-house testing conditions. Absence of impairment or
damage in all cases is not assured.
High-speed printing for checking data right on the spot Printer features newly designed roll paper drop-in loading and one-touch setup, along
with high 50 mm/s printing speed.
Ergonomic controls for superior user convenience
Large key tops are easy to operate and feature surface coating so you can simply wipe
off grease stains and other residue.
MEMORY HiCORDER
Recorders
8847
F
ully Isolated High Speed Recording, Tough Enough for the Field
2
The Ideal Recorder for Field Use Features Easy Portability and Sturdy Construction
No Delay
3
A problem occurs, requiring immediate attention on site
Grab the sturdy handle and go. The tough construction can
take a few knocks.
Start measurement without reading through the manual
The Help Wizard assists you to do exactly what you want.
Print out results on the spot
Load printer paper with a simple one-touch operation.
High printing speed gives you a hard copy in a snap.
High Speed
High-speed sampling up to 20 MS/s
Full isolation for all channels and simultaneous sampling
Store data on media three times faster
To 30 MB CF Card: Max. 40 seconds
(8841: approx. 110 seconds)
Data save speed may vary, depending on conditions.
X-Y
Operation
Multi-channel X-Y recorder with electronic data log
Simultaneous recording over 16 analog + 16 logic channels
Simultaneous recording over 64 logic + 10 analog channels
Plug-in modules provide the flexibility to match most
channel and signal confi guration requirements.
Computer
Integration
Easy storage of recorded data
USB memory stick / CF card / internal hard disk
HTTP/FTP server function and remote operation capability
provide easy access to data
4
One-touch design takes the hassle out of the process. 50mm/sec print speed
Start a measurement without delay
No more need for cumbersome and time-consuming steps such as threading the paper between rubber rollers and the thermal print head. Simply drop the paper roll in place, pull the tip out slightly, and close the door. As easy as one, two, three.
What
Users
Want
No Problem!
Actual size of printout example
Print a complete A4 format report on site
If the customer requires a report, the 8847 can deliver without delay. The A4 format printout shows waveforms with high resolution. Even minute details and changes can be detected easily, and measurement parameters used for obtaining the data are also printed. Even in the age of electronic communication, being able to produce a paper document on the spot can be very effective and result in enhanced credibility.
Hard copy of the display screen, then and there
Observed waveforms, setup pa rameters, processing values, AB cursor readouts and more--a simple push of a button and the hi gh-speed ther mal printer g ives you a hard co py of the en tire scre en contents. Saving as a BMP file on a CF card or USB memory is also possible.
Printing is tw ice a s fas t compa red t o the performanc e o f previous HIOKI products. No more waiting when printing out data on site to give to the customer.
"The customer needs measurement results in hand right away!"
50 mm/s printing speed produces results in a flash
No Problem!
"Changing paper is a hassle, and printing speed should be faster!"
5
Making input ampli tude and trigger settings becomes much easier when the effect can be observed immediately. Setting va lue s can be su perimpo sed on the wa v e f o rm d i spla y to maximize the waveform area, or you can separate the display areas to enhance the legibility of setting items.
"Making settings is too complicated if I can't see the waveform!"
Make settings on screen while watching the waveform.
No Problem!
Input
Input
A/D conversion
Write to memory
Input voltage
Sampling period
Time
Output waveform
Bar graph type level monitor
Input channel upper limit
Input channel lower limit
Time per division on horizontal axis
Sampling period s hown in bracke ts ( )
Duration to be stored in internal memory
Conver ted time valu e shown in brackets ( ) 100 sampling points pe r division
Trigger mode and pretrigger Specifi es interval to observe before trigger point
Input channel instantaneous value monitor
(numeric readout)
Versatile trigger functions
What
Users
Want
Monitor high-speed signals
High-speed 20 MS/s sampling provides ample margin
The operation principle is the same as for a digital oscilloscope: data are stored at high speed in the high-capacity internal memory. Even with all channels operating simultaneously, sampling rates up to 20 megasamples per second (50 ns cycle) are possible. This ensures that sudden event spikes and instantaneous waveform changes are captured reliably.
Semiconductor memory storage
Units using hard disks or other mechanical media for storage are vulnerable to vibrations and therefore are not ideal for automotive measurement and similar applications. By saving data in semiconductor based memory without any mechanical drive parts, the Memory HiCorder is much more suited to such applications. Simply back up the data later to CF card or USB memory, and you're done.
No Problem!
"1 MS/s is too slow for observing fast pulse edges"
A/D conversion
Insulation
Insulation
Screen display Print out
Duration to be stored in internal memory
Conver ted time valu e shown in brackets ( )
6
EXT. IN 1 EXT. IN 2 EXT. IN 3
Pen up/down control
Individual pen up/down control is possible during X-Y recording, not only by using the Function buttons but also via external signals at the EXT. IN1, 2, 3 connectors.
Having an X-Y recorder would be handy!
What
Users
Want
Chart-type X-Y recorders are disappearing from the market, but they had certain advantages that are sometimes desirable. The 8847 brings them back with features such as independent pen up/ down control. Because data are stored as a time­based series, electronic storage can be applied to tasks for which paper archives used to be necessary.
"An X-Y recorder uses paper, but electronic data would be better!"
X-Y recorder with electronic recording
No Problem!
The 8847 comes standard with 16 logic input channels. Three more logic input modules with up to 48 logic channels can be installed in place of analog input modules, resulting in simultaneous recording c apa c ity f or up t o 64 ch an n els i n total. All channels can be displayed on a single screen, which is ideal for timing measurements. Furthermore, simultaneous recording of analog waveforms is possible in up to 10 channels.
"There are scores of relays, and I need to measure the timing of them all!"
Max. 64 channels Logic input
+ 10 channels Analog input
No Problem!
7
HUB
Waveform observation/CSV conversion software bundled as standard (Wv)
Binary data collected with the HiCorder can be observed as
waveforms on a computer.
Data can be converted to CSV format for importing into
Excel. The software is supplied free of charge with the product, and the latest version can also be downloaded from the HIOKI web site.
USB receptacle A
USB receptacle B
LAN terminal
Wv screen sample
EXCEL sheet sample
What
Users
Want
Analyze data on a computer
Measurement data can be saved manually on any generic USB memory device.
* Automatic data saving as on CF card is not possible.
The USB interface conforms to version 2.0 specifications. Mass storage devices can be used in the A type connector.
* Due to compatibility reasons, some USB memory devices may not work.
The B type connector can be u sed to connect the 8847 to a computer for remote operation. If no USB memory stic k is available, internal data of the 8847 can be sent to the computer via this USB connection for storage.
"I want to use a USB memory stick!"
Two types of USB 2.0 ports
No Problem!
Measurement data can be saved automatically on the optional 80GB hard disk. The HDD is a factory option which will be installed internally. A slot for CompactFlash cards is also provided. Data can be saved automatically on cards available from HIOKI.
* Automatic data saving occurs in close to real time and is possible while saving
data in the internal memory (128MB) of the HiCorder. Automatic data saving on USB memory is not possible. Data must be saved manually on such media.
"I want to use a hard disk!"
Optional internal HDD
No Problem!
A 100BASE-TX LAN port is built in as standard equipment. <HTTP server capability> Access the unit via a web browser running on a computer, for waveform observation and remote operation. Waveform data of the 8847 can also be downloaded and pasted into Excel. <FTP server capability> Copy the memory contents of the 8847 (internal RAM, CF card, HDD) to a computer.
"I want to hook up to a LAN!"
LAN port and HTTP/FTP server function
No Problem!
8
- Numerical calculation function -
- Partial waveform zooming -
- Comment input capability without a keyboard -
Numerical calculation results can be shown on waveform display
Numerical calculation settings
Evaluation settings
Evaluation settings
While observing the entire waveform, zoom in on portions of interest
Comments can be input for each channel
Calculate parameter values from measured waveform
20 different built-in calculation types including effective
(rms) value, peak value, and maximum value
Highlights
Partial waveform zooming
Display time axis compressed waveform in upper part of
screen
Display time axis expanded waveform in lower part of screen
Use Jog & Shuttle knobs to scroll to desired section
Enter comments for each measurement signal
Assign comments to channels and display them
on screen
Print channel comments when printing
waveforms
Make entries without a keyboard
9
Maximum recording times with Memory function (auto saving)
At sampling speeds of 100 ms/division (1 ms sampling) and lower, real-time saving on media becomes possible.
• Sett ing record ing length t o an arbit rary value allows incre asing the 200,000 div ision limit u p to a maxi mum of
320,000 divisions in 1 division units.
Input
Input
A/D
A/D
Insulation
Screen display
Maximum Value
Minimum Value
Recording Speed
REC
time ax is
Sampling period
To internal me mory
20,000 di visions
Contin uous (appr ox. recording t ime with one 30 m paper roll)
Note: Calculated as 30 m = 2,970 divisions Changing paper enables permanent continuation of recording
100 ms/div
1 ms, 10 ms, 100 ms, 1 ms, 10 ms, 100 ms
Note: Limited by combination of selections under 1/100 on
time axis and time axis setting
for memory recording
33 min 20 s Display only 200 ms/div 1 h 6 min 40 s Display only 500 ms/div 2 h 46 min 40 s 24 min 45 s
1 s/div 5 h 33 min 20 s 49 min 30 s 2 s/div 11 h 6 min 40 s 1 h 39 min 00 s
5 s/div 1 d 3 h 46 min 40 s 4 h 7 min 30 s 10 s/div 2 d 7 h 33 min 20 s 8 h 15 min 00 s 30 s/div 6 d 22 h 40 min 00 s 24 h 45 min 00 s 50 s/div 11 d 13 h 46 min 40 s 1 d 17 h 15 min 00 s
100 s/div 23 d 3 h 33 min 20 s 3 d 10 h 30 min 00 s 1 min/div 13 d 21 h 20 min 00 s 2 d 1 h 30 min 00 s 2 min/div 27 d 18 h 40 min 00 s 4 d 3 h 00 min 00 s 5 min/div 69 d 10 h 40 min 00 s 10 d 7 h 30 min 00 s
10 min/div 138 d 21 h 20 min 00 s 20 d 15 h 00 min 00 s
30min/div 416 d 16 h 00 min 00 s 61 d 21 h 00 min 00 s
1 hr/div 833 d 8 h 00 min 00 s 123 d 18 h 00 min 00 s
- Simultaneous recording on recording media -
- Chart recording reliably captures noise events -
Maximu m recording time
increas es depending on
number of c hannels used
Analo g 16 ch
+ internal L ogic 16 ch
Analo g 8 ch
+ internal L ogic 16 ch
Analo g 4 ch
+ internal L ogic 16 ch
Analo g 2 ch
+ internal L ogic 16 ch
Logic 48 c h
+ internal L ogic 16 ch
Time a xis
Samp. period
20,000 di v 50,000 d iv 100,000 di v 200,000 d iv 100,000 d iv
5 μs/div to
50 ms/div
50 ns to
500 μs
- omitted - - omitted - - omitted - - omitted - - omitted -
100 ms/div 1 ms
33 min 20 s
1 h 23 min 20 s 2 h 46 min 40 s 5 h 33 min 20 s 2 h 46 min 40 s
200 ms/div 2 ms
1 h 06 min 40 s 2 h 46 min 40 s 5 h 33 min 20 s 11 h 06 min 40 s 5 h 33 min 20 s
500 ms/div 5 ms
2 h 46 min 40 s 6 h 56 min 40 s 13 h 53 min 20 s
1 d 03 h 46 min 40 s
13 h 53 min 20 s
1 s/div 10 ms
5 h 33 min 20 s 13 h 53 min 20 s
1 d 03 h 46 min 40 s 2 d 07 h 33 min 20 s 1 d 03 h 46 min 40 s
2 s/div 20 ms
11 h 06 min 40 s
1 d 03 h 46 min 40 s 2 d 07 h 33 min 20 s 4 d 15 h 06 min 40 s 2 d 07 h 33 min 20 s
5 s/div 50 ms 1 d 03 h 46 min 40 s 2 d 21 h 26 min 40 s 5 d 18 h 53 min 20 s 11 d 13 h 46 min 40 s 5 d 18 h 53 min 20 s 10 s/div 100 ms 2 d 07 h 33 min 20 s 5 d 18 h 53 min 20 s 11 d 13 h 46 min 40 s 23 d 03 h 33 min 20 s 11 d 13 h 46 min 40 s 30 s/div 300 ms 6 d 22 h 40 min 00 s 17 d 08 h 40 min 00 s 34 d 17 h 20 min 00 s 69 d 10 h 40 min 00 s 34 d 17 h 20 min 00 s 50 s/div 500 ms 11 d 13 h 46 min 40 s 28 d 22 h 26 min 40 s 57 d 20 h 53 min 20 s 115 d 17 h 46 min 40 s 57 d 20 h 53 min 20 s
100 s/div 1.0 s 23 d 03 h 33 min 20 s 57 d 20 h 53 min 20 s 115 d 17 h 46 min 40 s 231 d 11 h 33 min 20 s 115 d 17 h 46 min 40 s 1 min/div 600 ms 13 d 21 h 20 min 00 s 34 d 17 h 20 min 00 s 69 d 10 h 40 min 00 s 138 d 21 h 20 min 00 s 69 d 10 h 40 min 00 s 2 min/div 1.2 s 27 d 18 h 40 min 00 s 69 d 10 h 40 min 00 s 138 d 21 h 20 min 00 s 277 d 18 h 40 min 00 s 138 d 21 h 20 min 00 s 5 min/div 3.0 s 69 d 10 h 40 min 00 s 173 d 14 h 40 min 00 s 347 d 05 h 20 min 00 s 694 d 10 h 40 min 00 s 347 d 05 h 20 min 00 s
Input
A/D
conversion
A/D
conversion
Write to memory
Write to media
Chart recording reliably captures noise events (Recorder function)
High-speed sampling ensures that noise events are captured also with slow recording
Data compression achieved by recording maximum/minimum value pairs
Up to 416 days of recording time with maximum memory capacity (1 hour/division)
Chart output enables permanent recording
* When opening data created with the Recorder function on a computer, the maximum and minimum
data pairs are lined up in a time series. * Length of printer paper roll is 30 meters. Paper can be changed during operation without stopping the recording process.
Write to memory
Recording on chart
Maximum recording times with Recorder function
With settings betwe en 100 and 200 m s per divisi on on the time a xis, c ontinuo us re cording is not
possible if printer is ON.
Highlights
Memory
function
Recorder function
Simultaneous recording on recording media (Memory function)
Automatic data saving on CF card or HDD
During high-speed sampling, data are written to internal
RAM first and later saved on other media
During low-speed sampling, data are written to internal RA M
and sequentially saved on other media
Highly suitable for long-term recording
* Available recording duration is determined by internal RAM capacity, not by
exter nal media.
Input
Input voltage
Sampling period
Time
10
Time domain
Frequency domain
1,000 points
Convert 1,000 to 10,000 points
Before scaling
After scaling
Waveform in the MEM function
Recalculate by changing the number of calculation points after measurement
Even for measurement data currently based on a lower number of calculation points, it is possible to increase the number later and perform analysis again. For example, data measured at a setting of 1,000 points can be converted and reanalyzed with a 10,000 point setting. This will result in a tenfold increase in frequency analysis resolution. Of course, the opposite is also possible, going for example from 10,000 points to 1,000 points.
* Recalculation with a different number of calculation points is not possible if frequency
averaging is set to ON.
Decibel-based scaling
Decibel-based scaling as requested by numerous customers is now possible. There is no more need to make logarithmic conversions on the side with an electronic calculator. The 8847 can accept input of overall values (power spectrum sum) in dB, with the capability for easy scaling. Signals from noise level meters and similar equipment can therefore be read directly.
function available from version 2.00 onward
- Frequency area data analysis (FFT function) -
- Electrical distortion analysis/mechanical vibration analysis -
Highlights
This function comprises single-signal FFT for tasks such as frequency component analysis, dual-signal FFT for transfer function analysis, and octave analysis for acoustic measurements. The signal source for analysis are specified sections from waveform data captured using the Memory function.
* The selectable range is 1,000 to 10,000 data points.
Compared to the predecessor model 8841, processing speed is about
1.6 times faster (internal clock ratio) when performing the most time­intensive analysis calculation under the same conditions.
FFT analysis function
To use measurement data captured with the Memory function, the Jog & Shuttle knobs serve to specify analysis points, and processing results can now be displayed at the same time. Compared to earlier models such as the 8855 and 8841, operation has been significantly streamlined by eliminating the need to go back and forth between the Memory function and the FFT function. It is also possible to view raw data measured with the Memory function and processing results obtained from stored waveforms side by side. This makes it possible to check the effects of window functions while viewing spectrum waveforms, resulting in a dramatic improvement in operation convenience during use of the analysis functions.
FFT analysis from memory waveform data
Specify an analysis point
11
M e asure a variety of s ignals in on e go
Find problem sol u tio ns s traigh t away
Power facilities
Generating stations
Transformer stations
Steel and chemical plants
Short-circuit/interruption
testing
Facilities diagnosis
Troubleshooting
Motors
Railways/Transport
Automotive
Development and testing
Fault and problem
analysis
Quality control
Elevators
Machine tools and
hydraulic machinery
Production facilities
Maintenance
Troubleshooting
Performance and
characteristics testing
Application example
Load interruption test at generator
Use pretrigger function to record waveform before and after
interruption
Test breaker characteristics
Use multiple isolated input channels simultaneously
Instantly load paper and print out full-width waveform
Application example
Commercial power supply line
measurement
Use drop trigger to monitor voltage drops
Evaluate waveform when switching to UPS or other source
Use instantaneous waveform recording for 50/60 Hz
Isolated inputs eliminate short-circuiting risks
Application example
Railway carriage problem analysis
Use pretrigger function to record instantaneous waveform
before and after problem
Check notch curves and cam progression waveform
Use logic probe to record cam contact point signal waveform
Record MG startup current waveform using clamp sensor
Application example
Motor startup current measurement
Observe correlation between main motor current waveform
and relay signal
Record up to 3 m 20 s at 1/1000 s (1 ms per division)
Make simultaneous current and voltage measurements using
multiple channels and isolated inputs
Use trigger wait function to pinpoint and record problem
waveforms only
Application example
Measurement of hydraulic machinery
operation waveform
Perform braking mechanism measurement
Perform X-Y measurement of valve fl ow and pressure
Perform X-Y measurement of load and displacement
Use pen up/down and playback functions
Application example
Check for bearing wear and
deterioration
Perform FFT analysis over a frequency range from DC to 8
MHz
Perform long-term signal recording and analyze only
required parts
Use FFT analysis to diagnose cracks and similar problems
Note: FFT analysis function available from version 2.00 onward
12
MEMORY (high-speed recording)
Time axis
5 μs to 5 min/division (100 points/div) 26 ranges, External sam-
pling (100 points/div, or free setting),
Time axis zoom: ×2 to ×10 in 3 stages, compression: 1/2 to
1/20,000 in 13 stages
Sampling rate
1/100 of time axis range (minimum 50 ns period)
Recording length
16 ch mode : built-in presets of 25 to 20,000 divisions 8 ch mode : built-in presets of 25 to 50,000 divisions 4 ch mode : built-in presets of 25 to 100,000 divisions 2 ch mode : built-in presets of 25 to 200,000 divisions or free setting in 1-division steps (max. 320,000 div)
Pre-trigger
Record data from before the trigger point, 0 to +100% or -95%
of recording length 15 stages
Numerical calculation
• Simultaneous calculation for up to 16 selected channels
Average value, effective (rms) value, peak to peak value, maxi-
mum value, time to maximum value, minimum value, time to minimum value, period, frequency, rise time, fall time, standard deviation, area value, X-Y area value, specified level time, specified time level, pulse width, duty ratio, pulse count, four arithmetic operations
• Calculation result evaluation output: GO/NG (with open-
collector 5 V output)
• Automatic storing of calculation results
Other functions
• Averaging (cumulative average, exponential average, with unit
firmware version 2.00 and later)
• No logging
• X-Y waveform synthesis (1-screen, 4-screens)
• Overlay (always overlay when started/overlay only required
waveforms)
• Automatic/manual/AB cursor range printing/report printing
Additional functions
Note: By installing optional
Functi on Expansion S oftware
9785 in unit
• Waveform calculation: For up to 8 freely selectable channels,
the following functions can be performed
(results are automatically
stored)
: Four arithmetic operations, absolute value, exponentia­tion, common logarithm, square root, moving average, differen­tiation (primary, secondary), integration (primary, secondary), parallel displacement along time axis, trigonometric functions, reverse trigonometric functions
• Memory splitting (max. 1024 blocks): sequential storage,
multi-block storage
RECORDER (real-time recording)
Time axis
10 ms to 1 hour per division, 19 ranges, time axis resolution
100 points/division
* Out of data acquired at selected sampling rate, only
maximum and minimum value data determined using 100 points/division units
are stored
Time axis compression selectable in 13 steps, from × 1/2 to ×
1/20,000
Sampling rate
1/10/100 µs 1/10/100 ms
(selectable from 1/100 or less of time axis)
Real-time printing
Supported
* Real-time printing is possible at time axis settings slower than 500 ms per
division
* Delayed print is performed when recording length is not set to “ Continuous”
and time axis setting is 10 ms - 200 ms per division
* When recording length is set to “ Continuous” and time axis setting is 10 ms -
200 ms per division, manual printing can be performed after measurement stop
Recording length
Built-in presets of 25 to 20,000 divisions, or “Continuous” or free setting in 1-division steps (max. 20,000 div)
Additional recording
Supported (recording is resumed without overwriting previous data)
* With unit firmware version 2.00 and later
Waveform memory
Store data for most recent 20,000 divisions in memory
*Backward scrolling and re-printing available
Auto save
Data are automatically saved on CF card or internal HDD after
measurement stop
Other functions
• No logging
• Event recording (screen during measurement/marker input for
print recording)
* With unit firmware version 2.00 and later
• Manual/AB cursor range printing/report printing
X-Y RECORDER (X-Y real-time recording)
Sampling rate
1/10/100 ms (dot), 10/100 ms (line)
Recording length
Continuous
Screen, Printing
Split screen (1 or 4), Manual printing only
Number of X-Y
1 to 8 phenomenon
X-Y channel setting
Any 8 channels out of 16 can be selected for X axis and Y axis
respectively
X-Y axis resolution
25 dots/division (screen), 80 dots (horizontal) × 80 dots
(vertical)/division (printer)
Waveform memory
Sampling data for last 2,000,000 points are stored in memory
Pen up/down
Simultaneous for all phenomena
External pen control
Possible via external input connector (simultaneous up/down for
all phenomena)
Internal Printer
Features
Printer paper one-touch loading, high-speed thermal printing
Recording paper
216 mm
(8.50 in) × 30 m (98.43 ft), thermal paper roll (use 9231 paper)
Recording witdh: 200 mm (7.87 in) 20 division full scale, 1 div = 10 mm
(0.39 in) 80 dots
Recording speed
Max. 50 mm (1.97 in)/sec
Paper feed densit y
10 lines/mm
Display
Display
10.4 inch SVGA-TFT color LCD
(800 × 600 dots)
(Time axis 25 div × Voltage axis 20 div, X-Y 20 div × 20 div)
Displayable languages
English, Japanese, Korean, Chinese
Note: Chinese (available end of 2009)
Waveform display zoom/compression
Time axis: × 10 to × 2 (zoom at MEMORY function only), × 1, × 1/2 to × 1/20,000, Voltage axis: × 100 to × 2, × 1, × 1/2 to × 1/10
Variable display
Upper/Lower limit set, display/div set
Scaling
10:1 to 1000:1, automatic scaling for various probes Manual scaling
(conversion ratio setting, 2-point setting, unit setting)
Comment input
Alphanumeric input (title, analog and logic channels) Simple input, history input, phrase input
Logic waveform display
Display point move 1 % step, Line width 3 types
Display partition
Max. eight divisions
Monitor function
Input level monitor Numerical value
(Sampling 10kS/s fixed, refresh rate 0.5s)
Other display functions
• Waveform inversion (positive/negative)
• Cursor measurement (A, B, 2-cursor, for all channels)
• Vernier function (amplitude fine adjustment)
• Zoom function (horizontal screen division, zoomed waveform
shown in lower section)
• 16 selectable colors for waveform display
• Zero position shift in 1% steps for analog waveform
• Global zero adjust for all channels and all ranges
Basic specifi cations (product guaranteed for one year)
Measurement functions
MEMORY
(high-speed recording)
RECORDER (real-time recording) X-Y RECORDER (X-Y real-time recording)
FFT (frequency analysis) Note: function available from version 2.00 onward
Number of input modules
[8 analog input modules]: 16 analog channels + 16 logic channels
(standard)
[5 analog input modules + 3 logic input modules]: 10 analog
channels + 64 logic channels
(standard 16 channels + 48 channels in logic
input modules)
* For analog modules, channels are insulated vs. each other and vs. unit ground. For logic modules and integrated standard logic channels, all channels use the unit ground.
Maximum sampling rate
20 MS/second
(50 ns period, all channels simultaneously)
External sampling (10 MS/second, 100 ns period)
Direct access internal memor y
64 Mega-words
(Memory expansion: none)
32 Mega-words/ch
(using 2 Analog channels)
, 16 Mega-words/ch
(using
4 Analog channels)
, 8 Mega-words/ch
(using 8 Analog channels)
, 4 Mega-
words/ch
(using 16 Analog channels)
Note: 1 word = 2 bytes (12-bits or 16-bits), therefore 64 Mega-word = 128 Mega-bytes. Note: Internal memory is allocated depending on the number of channels used.
Data storage media
*
2 Factory installation only
CF Card slot (standard) × 1: up to 1GB, FAT, or FAT-32 format Hard disk drive
(option, HD UNIT 9664 *2) × 1: 80GB
Main unit Specifications
Backup functions
(at 25°C/ 77°F)
Clock and parameter setting backup: at least 10 years Waveform backup function: none
External control connectors
Terminal block: External trigger input, Trigger output, External
sampling input, Two external outputs (GO/NG output), Three external inputs (start, stop, print input)
External inter faces
LAN: RJ-45 connector, Ethernet 100BASE-TX Functions: DHCP, DNS supported, FTP server, HTTP server USB: USB2.0 compliant, series A receptacle 1 port, series B
receptacle 1 port
(file transfer to PC, remort control from PC)
Environmental conditions
(no condensation)
Operation: -10 °C (14 °F) to 40 °C (104 °F), 20 % to 80 % rh Printer use: 0 °C
(32 °F) to 40 °C (104 °F), 20 % to 80 % rh
HD use: 5 °C
(41 °F) to 40 °C (104 °F), 20 % to 80 % rh
Storage: -20 °C
(-4 °F) to 50 °C (122 °F), 90 % rh or less
Compliance standard
Safety: EN61010, EMC: EN61326, EN61000-3-2, EN61000-3-3
Power requirements
100 to 240 V AC
(50/60 Hz)
10 to 28 V DC
(use the DC POWER UNIT 9784 : option, factory installation only)
Power consumption
130 VA max. (printer not used), 220 VA max. (printer used)
Dimensions and mass
Approx. 351 mm
(13.82 in) W × 261 mm (10.28 in) H × 140 mm
(5.51 in) D, 7.6 kg (268.1 oz) (main unit only)
Supplied accessories
Instruction Manual × 1, Measurement Guide × 1, Application Disk
(Wave Viewer Wv, Communication Commands table) × 1,
Power cord × 1, Input cord label × 1, USB cable × 1, Printer paper
× 1, Roll paper attachment × 2
13
Measurement Indices (optional input module types)
• Each module has two input channels.
• Besides logic modules (16 channels), Model 8847 comes standard with 16 logic inputs integrated in the
device.
Trigger functions
Trigger mode
MEMORY
(high-speed recording) : Auto, Single, Repeat
RECORDER
(real-time recording) : Single, Repeat
Trigger sources
CH1 to CH16 (analog), Standard Logic 16ch + Logic Unit (Max. 3 units
48 channels), External (a rise of 2.5V or terminal short circuit), Timer , Manual (either ON or OFF for each source),
Logical AND/OR of sources
Trigger types
• Level: Triggering occurs when preset voltage level is crossed
(upwards or downwards).
• Voltage drop: Triggering occurs when voltage drops below
peak voltage setting (for 50/60 Hz AC power lines only).
• Window: Triggering occurs when window defined by upper
and lower limit is entered or exited.
• Period: Rising edge or falling edge cycle of preset voltage
value is monitored and triggering occurs when defined cycle range is exceeded.
• Glitch: Triggering occurs when pulse width from rising or
falling edge of preset voltage value is underrun.
• Event setting: Event count is performed for each source, and
triggering occurs when a preset count is exceeded.
• Logic: 1, 0, ×, pattern setting,
Level set ting resolution
0.1% of full scale (full scale = 20 divisions)
Trigger filter
OFF, setting range 0.1 to 10.0 divisions
(MEMORY: high-speed
recording)
,
ON (10 ms fixed)/OFF
(RECORDER: real-time recording)
Trigger output
Open collector (5 voltage output, active Low) at Level setting: pulse width (Sampling period × data number
after trigger)
at Pulse setting: pulse width (2ms)
Other functions
Trigger priority (OFF/ON), pre-trigger function for capturing
data from before/after trigger event (memory), level display during trigger standby, start and stop trigger for recorder (real­time recording)
FFT function (function available from version 2.00 onward)
Analysis mode
Storage waveform, linear spectrum, RMS spectrum, Power
spectrum, Cross power spectrum,
Auto-correlation function, Histogram, Transfer function, Cross-
correlation function, Impulse response, Coherence function, Octave analysis
Analysis channels
1 or 2 selected channels out of all analog channels
Frequency range
133 mHz to 8 MHz, External, (resolution 1/400, 1/800, 1/2000,
1/4000)
No.of sampling points
1000, 2000, 5000, 10000 points
Window functions
Rectangular, Hanning, Exponential
Averaging function
Time axis / frequency axis simple averaging, Exponential
averaging, Peak hold (frequency axis),
Averaging times: 2 times to 4,096 times
Other functions
• Display screen: Single, Dual, Nyquist
• Auto, Manual, Report printing
Measurement
target
With use i nput unit Measurement range Resolution
Voltage
ANALOG UNIT 8966
100 mV f.s. to 400 V f.s. 50 µV
HIGH RESOLUTION UNIT 8968
100 mV f.s. to 400 V f.s. 3.125 µV
DC/RMS UNIT 8972
100 mV f.s. to 400 V f.s. 50 µV
Current
* Using separate power supply
Use with the Clamp 9272-10 (20A), 9277, 3273-50, 3276
20 A f.s.
Note: 2 V f.s. voltage measurement
10 mA
Current
* Using separate power supply
Use with the Clamp 9272-10 (200A), 9278, 3274
200 A f.s.
Note: 2 V f.s. voltage measurement
0.1 A
Current
* Using separate power supply
Use with the Clamp 9279
500 A f.s.
Note: 2 V f.s. voltage measurement
0.25 A
Current
* Using separate power supply
Use with the Clamp 3275
500 A f.s.
Note: 2 V f.s. voltage measurement
0.25 A
RMS AC voltage
DC/RMS UNIT 8972
100 mV f.s. to 400 V f.s. 50 µV
Temperature
(thermocouple input)
TEMP UNIT 8967
200 °C f.s. to 2000 °C f.s.
Note: Upper and lower limit values depend on the thermocouple
0.01 °C
Frequency, rpm
FREQ UNIT 8970
20 Hz f.s. to 100 kHz f.s. 2 (kr/min) f.s. to 2000 (kr/min) f.s.
0.1 Hz 10 (r/min)
Commercial power
supply frequency
FREQ UNIT 8970
40 Hz f.s. to 60 Hz f.s. 50 Hz f.s. to 70 Hz f.s.
0.1 Hz
Pulse count
FREQ UNIT 8970
40 k counts f.s. to 20 M counts f.s.
20 counts
Pulse du ty ratio
FREQ UNIT 8970
100 % f.s. 0.5 %
Pulse width
FREQ UNIT 8970
0.01 s f.s. to 2 s f.s. 50 µs
Vibration/stress
STRAIN UNIT 8969
400 με f.s. to 20000 με f.s.
0.016 με
Relay co ntacts,
voltage on/off
LOGIC UNIT 8973
Maximum Recording Time for the Memory Function
• Operation cannot be guaranteed when the time axis is longer than one year.
• Setting recording length to an arbitrary value allows increasing the 200,000 division limit up to a maximum of 320,000 divisions in 1 division units.
PC Software Specifications
Note: With use of the 8847 , Wv ver 1.26 or later
Wave Viewer (Wv) Software (Application disk CD-R, bundled accessory)
Functions
• Simple display of waveform file
• Text conversion: convert binary data file to text format,
with selectable space or tab separators in addition to CSV, and specifiable section, thinning available
• Display format settings: scroll functions, enlarge/reduce
display, display channel settings
• Others: voltage value trace function, jump to cursor/trigger
position function
Compatible PC operating systems
Windows 95/98/Me, Windows NT 4.0 (SP3 or later), 2000,
XP
Maximu m recording time increas es depending on number of c hannels used
Analo g 16 ch
+ internal L ogic 16 ch
Analo g 8 ch
+ internal L ogic 16 ch
Analo g 4 ch
+ internal L ogic 16 ch
Analo g 2 ch
+ internal L ogic 16 ch
Logic 48 c h
+ internal L ogic 16 ch
Time a xis
Samp. period
20,000 di v 50,000 d iv 100,000 di v 200,000 d iv 100,000 d iv
5μs/div 50ns
100ms 250ms 500ms 1s 500ms
10μs/div 100ns
200ms 500ms 1s 2s 1s
20μs/div 200ns
400ms 1s 2s 4s 2s
50μs/div 500ns
1s 2.5s 5s 10s 5s
100μs/div 1μs
2s 5s 10s 20s 10s
200μs/div 2μs
4s 10s 20s 40s 20s
500μs/div 5μs
10s 25s 50s 1min 40s 50s
1ms/div 10μs
20s 50s 1min 40s 3min 20s 1min 40s
2ms/div 20μs
40s 1min 40s 3min 20s 6min 40s 3min 20s
5ms/div 50μs
1min 40s 4min 10s 8min 20s 16min 40s 8min 20s
10ms/div 100μs
3min 20s 8min 20s 16min 40s 33min 20s 16min 40s
20ms/div 200μs
6min 40s 16min 40s 33min 20s
1h 06min 40s
33min 20s
50ms/div 500μs
16min 40s 41min 40s
1h 23min 20s 2h 46min 40s 1h 23min 20s
100 ms/div 1 ms
33 min 20 s
1 h 23 min 20 s 2 h 46 min 40 s 5 h 33 min 20 s 2 h 46 min 40 s
200 ms/div 2 ms
1 h 06 min 40 s 2 h 46 min 40 s 5 h 33 min 20 s 11 h 06 min 40 s 5 h 33 min 20 s
500 ms/div 5 ms
2 h 46 min 40 s 6 h 56 min 40 s 13 h 53 min 20 s
1 d 03 h 46 min 40 s
13 h 53 min 20 s
1 s/div 10 ms
5 h 33 min 20 s 13 h 53 min 20 s
1 d 03 h 46 min 40 s 2 d 07 h 33 min 20 s 1 d 03 h 46 min 40 s
2 s/div 20 ms
11 h 06 min 40 s
1 d 03 h 46 min 40 s 2 d 07 h 33 min 20 s 4 d 15 h 06 min 40 s 2 d 07 h 33 min 20 s
5 s/div 50 ms 1 d 03 h 46 min 40 s 2 d 21 h 26 min 40 s 5 d 18 h 53 min 20 s 11 d 13 h 46 min 40 s 5 d 18 h 53 min 20 s 10 s/div 100 ms 2 d 07 h 33 min 20 s 5 d 18 h 53 min 20 s 11 d 13 h 46 min 40 s 23 d 03 h 33 min 20 s 11 d 13 h 46 min 40 s 30 s/div 300 ms 6 d 22 h 40 min 00 s 17 d 08 h 40 min 00 s 34 d 17 h 20 min 00 s 69 d 10 h 40 min 00 s 34 d 17 h 20 min 00 s 50 s/div 500 ms 11 d 13 h 46 min 40 s 28 d 22 h 26 min 40 s 57 d 20 h 53 min 20 s 115 d 17 h 46 min 40 s 57 d 20 h 53 min 20 s
100 s/div 1.0 s 23 d 03 h 33 min 20 s 57 d 20 h 53 min 20 s 115 d 17 h 46 min 40 s 231 d 11 h 33 min 20 s 115 d 17 h 46 min 40 s 1 min/div 600 ms 13 d 21 h 20 min 00 s 34 d 17 h 20 min 00 s 69 d 10 h 40 min 00 s 138 d 21 h 20 min 00 s 69 d 10 h 40 min 00 s 2 min/div 1.2 s 27 d 18 h 40 min 00 s 69 d 10 h 40 min 00 s 138 d 21 h 20 min 00 s 277 d 18 h 40 min 00 s 138 d 21 h 20 min 00 s 5 min/div 3.0 s 69 d 10 h 40 min 00 s 173 d 14 h 40 min 00 s 347 d 05 h 20 min 00 s 694 d 10 h 40 min 00 s 347 d 05 h 20 min 00 s
14
Options specifications
(sold separately, for the 8847 only)
ANALOG UNIT 8966
(Accuracy at 23 ±5 °C/73 ±9 °F, 20 to 80 % rh after 30 minutes of warm-up
time an d zero adjustme nt; accuracy/ product guar anteed for 1 year)
Measurement functions
Number of channels: 2, for voltage measurement
Input connectors
Isolated BNC connector
(input i mpedance 1 M Ω, input capac itance 30 pF)
,
Max. rated voltage to earth: 300 V AC, DC
(with input isolated from the unit, the maximum voltage that can be applied between input channel and chassis and between input channels without damage)
Measurement range
5 mV to 20 V/div, 12 ranges, full scale: 20 div, AC voltage for possible
measurement/display using the memory function: 280 V rms,
Low-pass filter: 5/50/500 Hz, 5 k/50 k/500 kHz
Measurement resolution
1/100 of measurement range
(using 12-bit A/D conversion and when installed in the 8847)
Highest sampling rate
20 MS/s (simultaneous sampling across 2 channels)
Measurement accuracy
±0.5 % of full scale (with filter 5 Hz, zero position accuracy included)
Frequency characteristics
DC to 5 MHz -3 dB, with AC coupling: 7 Hz to 5 MHz -3dB
Input coupling
AC/DC/GND
Max. allowable input
400 V DC
(the maximum voltage that can be applied across input pins without damage)
Dimensions and mass: approx. 106 (4.17in) W × 19.8 (0.78in) H × 196.5 (7.74in) D mm,
approx. 250 g (8.8 oz) Accessories: None
TEMP UNIT 8967
(Accuracy at 23 ±5 °C/73 ±9 °F, 20 to 80 % rh after 30 minutes of warm-up
time an d zero adjustme nt; accuracy/ product guar anteed for 1 year)
Measurement functions
Number of channels: 2, for temperature measurement with
thermocouple (voltage measurement not available)
Input connectors
Thermocouple input: plug-in connector, Recommended wire diameter: single-wire, 0.14 to 1.5 mm
2
, braided
wire 0.14 to 1.0 mm
2
(conductor wire diameter min. 0.18 mm)
, AWG 26 to 16
Input impedance: min. 5 MΩ
(with line fault detection ON/OFF)
,
Max. rated voltage to earth: 300 V AC, DC
(with input isolated from the unit, the maximum voltage that can be applied between
input channel and chassis and between input channels without damage)
Temperature measurement range
Note: Upper and lower limit values depend on the thermocouple
10 °C/div
(-100 °C to 200 °C)
, 50 °C/div
(-200 °C to 1000 °C)
, 100 °C/div
(-200 °C to 2000 °C)
, 3 ranges, full scale: 20 div,
Measurement resolution: 1/1000 of measurement range
(using 16-bit
A/D conversion and when installed in the 8847)
Thermocouple range
(JIS C 1602-1995) (ASTM E-988-96)
K: -200 to 1350 °C, J: -200 to 1100 °C, E: -200 to 800 °C, T: -200 to 400 °C, N: -200 to
1300 °C, R: 0 to 1700 °C, S: 0 to 1700 °C, B: 400 to 1800 °C, W (WRe5-26): 0 to 2000 °C,
Reference junction compensation: intern al/ exter nal
(switchable)
,
Line fault detection ON/OFF possible
Data refresh rate
3 methods, Fast: 1.2 ms
(digital filter OFF), Normal: 100 ms (digital
filter 50/60 Hz)
, Slow: 500 ms (digital filter 10Hz)
Measurement accuracy
Thermocouple K, J, E, T, N: ±0.1 % of full scale ±1 °C
(±0.1 % of full scale ±2 °C at
-200 °C to 0 °C)
,
Thermocouple R, S, W: ±0.1 % of full scale ±3.5 °C
(at 0 °C to 400 °C or less)
, ±0.1
% of full scale ±3 °C
(at 400 °C or more)
Thermocouple B: ±0.1 % of full scale ±3 °C
(at 400 °C or more)
,
Reference junction compensation accuracy: ±1.5 °C
(added to measurement accuracy
with in ternal re ference jun ction compe nsation)
Dimensions and mass: approx. 106 (4.17in) W × 19.8 (0.78in) H × 204.5 (8.05in) D mm,
approx. 240 g (8.5 oz) Accessories: Ferrite clamp × 2
HIGH RESOLUTION UNIT 8968
(Accuracy at 23 ±5 °C/73 ±9 °F, 20 to 80 % rh after 30 minutes of warm-
up time a nd zero adjustm ent; accurac y/product gua ranteed for 1 yea r)
Measurement functions
Number of channels: 2, for voltage measurement
Input connectors
Isolated BNC connector
(input i mpedance 1 M Ω, input capac itance 30 pF)
,
Max. rated voltage to earth: 300 V AC, DC
(with input isolated from the unit, the maximum voltage that can be applied between input channel and chassis and between input channels without damage)
Measurement range
5 mV to 20 V/div, 12 ranges, full scale: 20 div, AC voltage for possible
measurement/display using the memory function: 280 V rms,
Low-pass filter: 5/50/500 Hz, 5k/50k Hz
Measurement resolution
1/1600 of measurement range
(using 16-bit A/D conversion and when installed in the 8847)
Highest sampling rate
1 MS/s (simultaneous sampling across 2 channels)
Measurement accuracy
±0.3 % of full scale (with filter 5 Hz, zero position accuracy included)
Frequency characteristics
DC to 100 kHz -3 dB, with AC coupling: 7 Hz to 5 MHz -3dB
Input coupling
AC/DC/GND
Max. allowable input
400 V DC
(the maximum voltage that can be applied across input pins without damage)
Dimensions and mass: approx. 106 (4.17in) W × 19.8 (0.78in) H × 196.5 (7.74in) D mm,
approx. 250 g (8.8 oz) Accessories: None
STRAIN UNIT 8969
(Accuracy at 23 ±5 °C/73 ±9 °F, 20 to 80 % rh after 30 minutes of warm-
up time a nd auto-balan ce; accuracy/pr oduct guar anteed for 1 year)
Measurement functions
Number of channels: 2, for distortion measurement (electronic
auto- balancing , balance adju stment range w ithin ±10000 με)
Input connectors
Weidmuller SL 3.5/7/90G
(via Conversion Cable 9769, TAJIMI PRC03-12A10-
7M10.5)
Max. rated voltage to earth: 33 Vrms or 70 V DC
(with input isolated from the unit, the maximum voltage that can be applied between input channel and chassis and between input channels without damage)
Suitable transducer
Strai n gauge conver ter, Bridge impedance: 120 Ω to 1 kΩ,
Bridge voltage: 2 V ±0.05 V, Gauge rate: 2.0
Measurement range
20 με to 1000 με/div, 6 ranges, f ull scale: 20 division,
Low-pass filter: 5/10/100 Hz, 1 kHz
Measurement resolution
1/1250 of measurement range (using 16-bit A/D conversion and when
installed in the 8847)
Highest sampling rate
200 kS/s (simultaneous sampling across 2 channels)
Measurement accuracy
±(0.5 % of full scale +4 με) (at 5 Hz filter ON, After auto-balancing)
Frequency characteristics
DC to 20 kHz +1/-3dB
Dimensions and mass: approx. 106 (4.17in) W × 19.8 (0.78in) H × 196.5 (7.74in) D mm,
approx. 220 g (7.8 oz) Accessories: Conversion cable 9769 × 2 (cable length 50 cm/1.64 ft)
DC/RMS UNIT 8972
(Accuracy at 23 ±5 °C/73 ±9 °F, 20 to 80 % rh after 30 minutes of warm-
up time a nd zero adjustm ent; accurac y/product gua ranteed for 1 yea r)
Measurement functions
Number of channels: 2, for voltage measurement, DC/RMS selectable
Input connectors
Isolated BNC connector
(input i mpedance 1 M Ω, input capac itance 30 pF)
,
Max. rated voltage to earth: 300 V AC, DC
(with input isolated from the unit, the maximum voltage that can be applied between input channel and chassis and between input channels without damage)
Measurement range
5 mV to 20 V/div, 12 ranges, full scale: 20 div, AC voltage for possible
measurement/display using the memory function: 280 V rms,
Low-pass filter: 5/50/500 Hz, 5 k/100 kHz
Measurement resolution
1/100 of measurement range (using 12-bit A/D conversion and when installed in 8847)
Highest sampling rate
1 MS/s (simultaneous sampling across 2 channels)
Measurement accuracy
±0.5 % of full scale (with filter 5 Hz, zero position accuracy included)
RMS measurement
RMS amplitude accuracy: ±1 % of full scale
(DC, 30 Hz to 1 kHz)
, ±3 %
of full scale
(1 kHz to 100 kHz)
,
Response time: SLOW 5 s
(rise time from 0 to 90% of full scale)
, MID 800 ms
(rise time from 0 to 90% of full scale)
, FAST 100 ms
(rise time from 0 to 90% of
full scale)
, Crest factor: 2
Frequency characteristics
DC to 400 kHz -3 dB, with AC coupling: 7 Hz to 400 kHz -3dB
Input coupling
AC/DC/GND
Max. allowable input
400 V DC
(the maximum voltage that can be applied across input pins without damage)
Dimensions and mass: approx. 106 (4.17in) W × 19.8 (0.78in) H × 196.5 (7.74in) D mm,
approx. 250 g (8.8 oz) Accessories: None
LOGIC UNIT 8973
(Product guaranteed for 1 year)
Measurement functions
Number of channels: 16 channels
(4 ch/1 probe connector × 4 connectors)
Input connectors
Mini DIN connector
(for HIOKI logic probes only),
Compatible logic probes: 9320
-01, 9327, 9321-01
Dimensions and mass: approx. 106 (4.17in) W × 19.8 (0.78in) H × 196.5 (7.74in) D mm,
approx. 190 g (6.7 oz) Accessories: None
15
Options specifications (sold separately)
LOGIC PROBE 9320-01/9327
(Accuracy at 23 ±5 °C/73 ±9 °F, 35 to 80 % rh ; acc uracy/produc t guaranteed for 1 year)
Function
Detection of voltage signal or relay contact signal for High/Low state recording
Input
4 channels
(common ground between unit and channels)
,
Digital/contact input switchable
(contact input can detect open-collector signals)
,
Input impedance: 1 MΩ
(with digital input, 0 to +5 V)
, 500 kΩ or more
(with
digital input, +5 to +50 V)
, pull-up resistance: 2 kΩ
(contact input: internally
pulled up to +5 V)
Digital input threshold
1.4 V/2.5 V/4.0 V
Contact input detection resistance
1.5 kΩ or higher
(open)
and 500 Ω or lower
(short)
, 3.5 kΩ or hig her
(open)
and 1.5 kΩ or lower
(short)
, 25 kΩ or hig her
(open)
and 8 kΩ or lower
(short)
Response speed
9320
-01
: 500 ns or lower, 9327: detectable pulse width 100 ns or higher
Max. allowable input
0 to +50 V DC
(the maximum voltage that can be applied across input pins without damage)
Cable length and mass: Main unit cable 1.5 m (4.92 ft), input section cable 30 cm (0.98 ft),
approx. 150 g (5.3 oz)
Note: The unit-side plug of the 9320-01 and 9327 is different from the 9320.
LOGIC PROBE 9321-01
(Accuracy at 23 ±5 °C/73 ±9 °F, 35 to 80 % rh ; acc uracy/produc t guaranteed for 1 year)
Function
Detection of AC or DC relay drive signal for High/Low state recording Can also be used for power line interruption detection
Input
4 channels
(isolated between unit and channels)
, HIGH/LOW range switching
Input impedance: 100 kΩ or higher
(HIGH range)
, 30 kΩ or hig her
(LOW
range)
Output (H) detection
170 to 250 V AC, ±DC (70 to 250 V ) (HIGH range) 60 to 150 V AC, ±DC (20 to 150 V) (LOW range)
Output (L) detec tion
0 to 30 V AC, ±DC (0 to 43 V) (HIGH range) 0 to 10 V AC, ±DC (0 to 15 V) (LOW range)
Response time
Rising edge 1ms max., falling edge 3ms max.
(with HIGH range at
200 V DC, LOW range at 100 V DC)
Max. allowable input
250 Vrms (HIGH range), 150 Vrms (LOW range) (the maximum voltage
that can be applied across input pins without damage)
Cable length and mass: Main unit cable 1.5 m (4.92 ft), input section cable 1 m (3.28 ft), approx.
320 g (11.3 oz)
Note: The unit-side plug of the 9321-01 is different from the 9321.
Cable length and mass: Main unit cable 1.3 m (4.27 ft), input section cable 46 cm (1.51 ft),
approx. 350 g (12.3 oz)
DIFFERENTIAL PROBE 9322
(Accuracy at 23 ±5 °C/73 ±9 °F, 35 to 80 % rh after 30 minutes of warm-up time, accuracy/product guaranteed for 1 year)
Function
For high-voltage floating measurement, power line surge noise
detection, RMS rectified output measurement
DC mode
For waveform monitor output, Frequency characteristics: DC to 10 MHz
(±3 dB)
,
Amplitude accuracy: ±1 % of full scale
(at max. 1000 V DC)
, ±3% of full
scale
(at max. 2000 V DC) (full scale: 2000 V DC)
AC mode
For detection of power line surge noise, frequency characteristics: 1 kHz to 10 MHz
±3 dB
RMS mode
DC/AC voltage RMS output detection, Frequency characteristics: DC, 40 Hz to 100 kHz, Response speed: 200 ms or less
(400 V AC)
, accuracy: ±1 % of full scale
(DC, 40 Hz to 1 kHz)
, ±4 % of full scale
(1 kHz to 100 kHz) (full scale: 1000 V AC)
Input
Input type: balanced differential input,
Input impedance/capacitance: H-L 9 MΩ/10 pF, H/L-unit 4.5 MΩ/20 pF,
Max. rated voltage to earth: when using grabber clip 1500V AC/DC
(CAT II)
,
600 V AC/DC
(CAT III)
, when using alligator clip: 1000 V AC/DC
(CAT II)
,
600 V AC/DC
(CAT III)
Max. allowable input
2000 V DC, 1000 V AC (CAT II), 600 V AC/DC (C AT III )
Output
Voltage divider for 1/1000 of input, BNC connectors
(output switchable for 3 modes DC, AC, RMS)
Power source
(1) Connect the AC ADAPTER 9418-15, (2) Connect to HiCORDER
logic terminal via the POWER CORD 9324 and CONVERSION CABLE 9323
Dimensions and mass: approx. 290 (11.42in) W × 29 (1.14in) H × 219.5 (8.64in) D mm,
approx. 1.2 kg (42.3 oz) Accessories: None
DC POWER UNIT 9784
Rated input voltage
10 to 28 V DC
Power requirements
200 VA (printer used)
Note: Factory-installed option, build in on the rear of the main unit
DC power supply module
integrated on rear panel
Right side
External control
terminals
Standard logic
inputs
Input modules can be
freely interchanged
WAVE PROCESSOR 9335
Distribution media
One CD-R
Operating environment
Computer equipped with Pentium (133 MHz) or better CPU and at least 32 MB of memory, and running under Windows 95/98/Me, Windows NT 4.0/2000/XP, or Windows Vista 32-bit type
(recommended system:
Pentium (200 MHz) or better with at least 64 MB of memory)
Display functions
Waveform display/X-Y display/digital value display/cursor function/ scroll function/maximum number of channels (32 channels analog, 32 channels logic)/gauge display (time, voltage axes )/graphical display
File loading
Readable data formats (.MEM, .REC, .RMS, .POW) Maximum loadable file size: Maximum file size that can be saved by a given device (file size may be limited depending on the computer configuration)
Data conversion
Conversion to CSV format, tab delimited, space delimited/data culling (simple)/convert for specified channel/batch conversion of multiple files
Print functions
Print formatting (1 up, 2-to-1 6 up, 2-to-16 rows, X-Y 1-to-4 up) /preview/ hard copy functions usable on any printer supported by operating system
Other
Parameter calculation /search/clipboard copy/launchi ng of othe r applications
Data analysis on the computer
Features
Waveform display, data calculation, printing function
Factory-installed option *Must specify when ordering
Configuration of options
Note: Options described as ”factory-installed options” must be specified when ordering and cannot be installed by the user. Note: Product names appearing in this catalog are trademarks or registered trademarks of various companies.
PC Software
Voltage measurement for use with general input modules
CONNECTION CORD 9790
(Thin Type) CAT II 300 V, ultra-
flexible 2.8 mm (0.11 in) diameter test lead cable, 1.5 m (4.92 ft) length
Note: Attachment clips sold separately.
ALLIGATOR CLIP 9790
-01
Red/black set attaches to the ends
of test leads (9790)
GRABBER CLIP 9790
-02
Red/black set attaches to the ends
of test leads (9790)
CONTACT PIN 9790
-03
Red/black set attaches to the ends
of test leads (9790)
CONNECTION CORD 9197
For high voltage (up to 500 V), 1.8 m (5.91 ft) length
CONNECTION CORD 9198
For low voltage (up to 300 V), 1.7 m (5.58 ft) length
10:1 PROBE 9665
Max. rated voltage to earth is same as for input module, max. input voltage 1 kV rms (up to 500 kHz), 1.5 m (4.92 ft) length
100:1 PROBE 9666
Max. rated voltage to earth is same as for input module, max. input voltage 5 kV peak (up to 1MHz), 1.5 m (4.92 ft) length
Recommended
Tip Expa nders Attachment clips are sold separately from CONN ECTION CORD 9790. Purchase the appropriate attachment clips for you r application se parately
Tip Expanders
9790
-01
Tip Expanders
9790
-03
Tip Expanders
9790
-02
High-Voltage measurement for use with power supply
DIFFER ENTIAL PRO BE 9322
For up to 2 kV DC or 1 kV AC. Use with either AC Adapter 94 18-15
AC ADAPT ER 9418-15
For powering Differential probe 9322, 100 to 240 V AC
Not CE marked
WAVE PROCES SOR 9335
Data conversion, print functions, waveform display, compatible with Windows 95/98/Me, Windows NT 4.0/2000/XP, and Windows Vista 32-bit type.
Removable storage (CF card)
Supplied with PC Card adapter
PC CARD 256M 9727
(256 MB capacity)
PC CARD 512M 9728
(512 MB capacity)
PC CARD 1G 9729
(1 GB capacity)
PC Card Precaution
Use only PC Cards sold by HIOKI. Compatibility and performance are not guaranteed for PC cards made by other manufacturers. You may be unable to read from or save data to such cards.
3269
3273-50 3276
3274 3275
CLAMP ON PROBE 3276
DC to 100MHz wideband response,
mA-class current up to 30A rms
CLAMP ON PROBE 3275
DC to 2MHz wideband response,
mA-class current up to 500A rms
CLAMP ON PROBE 3274
DC to 10MHz wideband response,
mA-class current up to 150A rms
CLAMP ON PROBE 3273
-50
DC to 50MHz wideband response,
mA-class current up to 30A rms
POWER SU PPLY 3272
Connect and power up to one CLAMP
ON PROBE to use in combination with voltage input modules
POWER SU PPLY 3269
Connect and power up to four CLAMP
ON PROBEs to use in combination with voltage input modules
3272
Current measurement *Connect directly to the analog input module
MEMORY HiCORDER 8847
*
The MEMORY HiCORDER
8847
cannot operate alone. You must
install one or more optional input modules in the unit.
Printer options
Logic signal measurement
LOGIC PROBE 9320-01
4-channel type, for voltage/contact signal ON/OFF detection (response time 0.5 μsec, miniature terminal type)
LOGIC PROBE 9321-01
4 isolated channels, ON/OFF detection of AC/DC voltage (miniature terminal type)
LOGIC PROBE 9327
4-channel type, for voltage/contact signal ON/OFF detection (response time 0.1 μsec or higher, miniature terminal type)
CONVERSION CABLE 9323
Used for connecting the 9320/9321 to the 8847 MEMORY HiCORDERs, because the terminal shapes are different.
* This cable is not required for the small­terminal types 9327, 9320-01, and 9321-01.
Recommended Recommended
Install by inserting into the main unit. Can be replaced by user.
A NALOG UNIT 8966 TEMP UNIT 8967 HIGH RESOLUTION UNIT 8968 STRAIN UNIT 8969
...CONVERSION CABLE 9769, Two cables included
FREQ UNIT 8970
............(available middle 2009)
CURRENT UNIT 8971
............(available middle 2009)
DC/ RMS UNIT 8972 LOGIC UNIT 8973
Recommended
Input modules
Input cables are not supplied. Please purchase the appropriate cable for the intended application.
DC POWER UNIT 9784
Factory-installed option - not user
installable, built in on the bottom case. 10 to 28 V DC drive.
HD UNIT 9664
Factory-installed option. 80GB
Other options
CARRYING CASE 9783
Hard trunk type, also suitable for
shipping/transporting the 8847
RECORDING PAPER 9231
A4 width 216 mm (8.50 in) × 30
m (98.43 ft), 6 rolls/set
PAPER WINDER 220H
Paper width 70 to 220 mm (2.76
to 8.66 inch), 100V AC Only
Not CE marked
LAN CABLE 9642
Straight Ethernet cable, supplied with straight to cross conversion cable, 5 m (16.41 ft) length
CONNECTION CORD 9217
Cord has insulated BNC connectors at both ends, and connects to insulated BNC connectors on input module. 1.7 m (5.58 ft) length
CONNECTION CORD 9165
Cord has metallic BNC connectors at both ends, and connects to metallic BNC connectors. 1.5 m (4.92 ft) length
CONVE RSION ADAPTER 9199
Banana-to-BNC, use to connect to BNC
terminal on Input Module
Not CE marked
Combination example: 8847 (with mix of logic modules and standard analog modules) * 16 logic input channels installed as standard in unit, separate logic probes required
8847 × 1
Memory 64 MW
Logic 32 ch Logic 48 ch Logic 64 ch
Logic 64 ch Analog 2 ch Logic 64 ch Analog 4 ch Logic 64 ch Analog 6 ch Logic 64 ch Analog 8 ch Logic 64 ch Analog 10 ch
Logic input unit
8973 × 1 8973 × 2 8973 × 3 8973 × 3 8973 × 3 8973 × 3 8973 × 3 8973 × 3
Analog input unit
8966 × 1 8966 × 2 8966 × 3 8966 × 4 8966 × 5
Input cable
9198 × 2 9198 × 4 9198 × 6 9198 × 8 9198 × 10
PT 9303
Insulation transformer, 400V or 200V AC input, 10V AC output, for AC power line measurement. Required along with the Conversion Adapter 9199.
SENSO R UNIT 9555 -10
Power supply unit for the 9272 to the 9279 clamp sensors, except for connecting to the Current unit 8971, for signal output 92 17 is necessary.
CURRE NT UNIT 8971
CLAMP ON SENSOR 9272
-10
Enables observation of AC current waveforms. Input: 1 to 100kHz, selectable 20 and 200A rms ranges, 2V AC output
CONVE RSION CAB LE 9318
To connect the 9272 to 9279 and the 8 971
CLAMP ON PROBE 9018
-50
Enables observation of AC current waveforms. 40 Hz to 3 kHz response, input 10 A to 500 A range, output 0.2 V AC/range
CLAMP ON PROBE 9132
-50
Enables observation of AC current waveforms. 40 Hz to 1 kHz response, input 20 A to 1000 A range, output 0.2 V AC/range
Current measurement
* Use for commercial power line, 50/60 Hz (Useless the power supply)
Current measurement
* To connect the clamp-on sensor via the conversion cable, Band
width DC to 100 kHz class
UNIVE RSAL CLA MP ON CT 9277
Observe waveforms from DC to distorted AC. DC to 100kHz response, input 20A / output 2V AC
UNIVE RSAL CLA MP ON CT 9278
Observe waveforms from DC to distorted AC. DC to 100kHz response, input 200A / output 2V AC
UNIVE RSAL CLA MP ON CT 9279
Observe waveforms from DC to distorted AC. DC to 20kHz response, input 500A / output 2V AC, Not CE marked
AC/DC CURRENT SENSO R 9709
Pass through & high precision type, Observe
waveforms from DC to distorted AC. DC to 100kHz response, input 500A / output 2V AC
CONNEC TION CORD 92 17
Cord has insulated BNC connectors
at both ends, and connects to the
9555-10 and input module.
HEAD O FFICE :
81 Koizumi, Ue da, Nagano, 386-1192, Japan TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: os-com@hioki.co.jp
HIOKI USA CORPOR ATION :
6 Corporate Drive, Cra nbury, NJ 08512 USA TEL +1-609-40 9-9109 / FAX +1-609-409-9108 E-mail: hioki@hiokiusa.com
HIOKI ( Shanghai) Sales & Trading Co., Ltd. :
1608-1610 Shanghai Times Square O ffi ce, 93 Hua i Hai Zhong
, Shang hai, P.R.China P OSTCODE: 200 021
Road TEL +86 -21-6391-00 90/0092 FAX +86-21-63 91-0360 E-mail: info-sh@hioki.com.cn
Beijing Offi ce :
A-2602 Freetown, 58 Dong San H uan Nan Road Beijing, P.R.China PO STCODE: 100022 TEL +86 -10-5867-4080 /4081 FAX +86 -10-5867-4090 E-mail: info-bj@hiok i.com.cn
Guang zhou Offi ce :
Room A-3206, Victor y PlazaSe rvices C enter, No.103, Tiyuxi Road, Guan gzhou, P.R.China POSTCODE:510620 TEL +86 -20-38392673/2676 FAX +86-20-38392679 E-mail: info-gz@hioki.com.cn
All in formatio n correct a s of Apr. 27, 2009. All spec ifi cation s are subjec t to change wit hout notice. 8847E4-94E-00P Printed in Japan
DISTRIBUTED BY