OWTS HV 150
Partial Discharge Diagnosis System for HV Cables up to 150 kV
Benefits
damped AC voltages
Advanced PD detection and PD site
localisation Integrated dielectric losses - measurement Portable test system, compact design and
low weight Real-time analysis and reporting using
Explorer software
Technical data subject to change without notice. LFT_OWTS HV 150_eng_2007_18
sebaK MT is a reg istere d trade mark of th e sebaKMT grou p
Description
The oscillating wave test system (OWTS) is used to identify, evaluate and locate partial discharge (PD) faults in cable insulation and accessories in all types of high voltage power cables. The system consists of a notebook as a WLAN control unit and a HV unit. The HV unit contains a HV source and a resonance inductor with an integrated electronic switch to generate damped AC test voltage. The HV divider and the coupling capacitor are integrated in a separate unit together with the embedded controller for the digital data acquisition and PD signal processing. The storage, analysis and evaluation of the PD signals takes place in the notebook and can be done either on site or in the office. The PD fault location is based on the time domain reflection method. For the PD diagnosis the test object is charged to the pre­selected peak value by a HV source within a couple of seconds and afterwards shorted with an electronic 150kV switch via a resonance coil. Thus a sinusoidal damping AC voltage with low damping is created (DAC). Depending on the capacitance of the test object the AC frequency varies in the range from tens to hundreds of Hz. Since the DAC frequency of the test voltage is close to nominal AC service conditions all measured PD activities can be effectively evaluated. The PD inception voltage (PDIV), PD extinction voltage (PDEV) and the dielectric losses value can be easily determined due to the decaying amplitude of the test voltage. Critical PD levels responsible for the insulation degradation status of the cable insulation are important criteria in the evaluation. The analysis and evaluation of the typical PD parameter as well as the PD fault location supports the Asset Management for reliable decision criteria for maintenance- or replacement activities.
Features
PD diagnosis by means of damped AC voltage (DAC) PD level measurement according to IEC 60270 Adjustment features to optimize detection sensitivity Automatic calibration mode with joint location feature PC with WIN XP and WLAN for system control Real-time data processing Menu-driven unit to operate the test sequence Portable design, low weight, easy set-up on-site
Technical Data
Max. DAC output voltage 150 kVpeak / 106 kVrms DAC frequency range 20 Hz … 500 Hz Capacitance range 0.025 µF … 13 µF HV charging current 10 mA
PD measuring range 1 pC … 100 nC
PD level detection acc. to IEC 60270 Bandwidth for PD-
localisation
150 kHz … 45 MHz
Dissipation factor δ δ
0.1 % … 10 %
Power supply 115 / 230 V, 50 / 60 Hz Operating temperature -10 °C … +40 °C Weight app. 300 kg Components Unit 1 HV source and LTT switch Unit 2 (3 coils &basis) Ø: 650 mm, H: 1400 mm Unit 3 HV divider and DAQ Unit 4 Notebook app. 2 kg
Scope of delivery
HV unit with HV source, LTT switch and inductive coil with
base unit and three additional modules HV divider with controller and coupling capacitor Notebook with WLAN connection to the HV unit Safety-Box with HV ON/OFF ; Emergency OFF push button
and key switch Accessory bag Operating manual HV connection: Metallic corrugated flexi tube Set of connection cables Control cables OWTS Explorer Package, 2 Dongles, CD-ROM PD Calibrator