The Optimized Paperless Recorder in the Applications
Data Display that’s Easy-to-Read in the Field
The FX100 is a cost effective paperless recorder with highly optimized performance.
Measured data can be easily viewed on the FX’s versatile displays, even in the field.
Unlike data from chart recorders, electrically stored data can be archived and copied
securely, quickly and easily without taking up space. The FX100 delivers what all
companies demand: reductions in TCO, improved efficiency, and enhanced control.
Outstanding Display and Flexible Operation
A Wide Variety of Highly Visible Displays
• 5.5’’ TFT color LCD display with wide viewing angle
• Trend, digital, bar, overview, information, and historical displays
• 4 display groups and 6 channels per group: Freely assignable measurement and
mathematical channels
• Display languages: English, German, French, or Japanese
Versatile Measurement
• Universal input and optional inputs (pulse and Pt1000 input)
• Up to 50 VDC direct input, no need of external voltage divider
• Up to 12 analog input channels
• Measurement interval: FX103: 250 ms
FX106, FX112: 1 s and 2 s
Simple and Easy Operation
• Interactive setup with Key panel’s navigation keys means easy operation
Dust-proof and Water-proof
(IP65)
• Can be installed in harsh environment
Easy Wiring
• Detachable analog input terminal makes it easy to wire
Powerful and Useful Functions
Powerful Computation Functions beyond Simple Calculation (/M1 Option)
• Multiple computations for measurement channels
• Displays and records12 mathematical channels
• Report function generates periodical report
Example
Detachable clamp terminal
- When ch02 is high,
ch01 value is accumulated.
- When ch01 is over measurement higher limit,
total time is accumulated.
Alarm Level
ch01
ch02
A Variety of Communication Option Combination (/C2, /C3, /C7 Option)
• The FX100 supports Ethernet, RS232, RS422A/RS485
• Communication interface can be used with the other options such as alarm output and fail/
FX100 back side
memory end.
• Ethernet interface and RS232 or RS422A/RS485 can be used together
Reliable Measurement Secure Data Acquisition PC Software
Meets Your Needs, Fits Your Applications
The FX100 provides an excellent alternative to chart recorders through enhanced data management and high performance. With a
powerful set of optional functions such as pulse input, Pt1000, and mathematical functions, the FX100 enables easy operation
tailored to your specific application, whether it be water treatment, wastewater treatment, heat treatment, process technology, or
environmental test equipment.
Data Display/Record in Wastewater Treatment
FX100 can display measured data and computation
results in real time.
■ Display and record Inputs data such as temperature, flow, turbidity,
pH, dissolved oxygen
■ Easy analysis data on the PC
■ Water quality management with the option Pt1000 (/N3):
Temperature display with high resolution
■ Pulse measurement up to 100Hz with option pulse input (/PM1):
Display/record of computations such as flow accumulation
Example
- Process flow (F1-F2) display/record.
The accumulation flow display on 31ch
Measurement:
Drawn flow(F1)
: ch01
Grit chamber Effluent chamber
Temperature/flow/turbidity
/pH/dissolved oxygen
Effluent flow (F2)
: ch02
Acquiring Sterilization Data for Food
Records sterilization process with optional mathematical
function (/M1): Easy F0 computation
L
Food sterilizer
■ Multi points and mixed inputs types (Temperature, F0, pressure, etc)
record
■ Improve efficiency by electric record
■ Measurement ON/OFF by external input (option)
■ Storing files by each test
L
5
L
5
L
4
L
4
L
3
L
3
L
L
2
2
L
1
L
1
S1S2S3S
4
S1S2S3S
4
∆t ∆tt
F0 is summation of area
F0 computation
Analysis/Report
Easy data conversion to Excel format
Ln-2
Ln-2
L
L
Sn-2 Sn-1
Sn-2 Sn-1
n
-1
n
-1
Temperature Recording/Monitoring for Aluminum Casting
Simplities casting temperature quality management.
■ Displays and records Aluminum casting data
- Molten metal temperature
- Cooling water temperature
■ Archives data upon alarm occurrence
- Analysis alarm data
Furnace data record
Molten metal temperature
Cooling water temperature
Melting furnace
Metal Mold
Data Display/Record in Environmental Chamber
FX100 measures accurate environmental test data and
displays data on versatile screen.
n
n
L
L
■ Records Data (temperature, humidity, voltage, current)
■ Versatile display enable easy interpretation of data
■ Easy data analyzing with PC software
■ Simple design and paperless recorder reduces TCO
Accurate measurement Versatile
displays
Delivers Stable Measurement
• FX100 uses High-breakdown-voltage Solidstate Relays as scanners for switching
signals, thus overcoming the problem of
defective measurement caused by faulty or
worn contacts of the mechanical contact.
• Resolution of A/D with 16 bits and isolated
channel inputs for DC voltage and TC input
make it stable measurement.
High-breakdown-voltage solid-state relays Data security in binary formatInternal flash memory
Protects Data When Power Interrupted
• The internal flash memory is nonvolatile
(requiring no battery backup), and holds
measurement data even during a power
interruption.
Keeps Your Data Secure
• FX100 saves measurement data in binary
format which provides high level of security.
Online/Offline Configuration
• Setting can be sent to or received from the
FX100.
Data Viewer/Conversion
• Data can be displayed, printed, or converted
to ASCII, Lotus 1-2-3 and Excel format.
Standard software DAQSTANDARD
Remote Monitoring for Water Distribution
Simple data acquisition over a wide area networking is available with optional Ethernet communication port (/C7 option).
■ Effective data management/data monitoring
via wide area networking
■ Can select no external media (reduces TCO)
Stores data file in FTP server
■ Real time data monitoring at remote sites
■ E-mail notification upon occurrence of alarm
■ Generates periodic report (/M1 option)
Flow turbidity
Temp pH
water treatment A
water treatment B
Periodical data transfer (/M1)
EX. Per each a week
Telephone line
(ISDN, Analog)
LAN/WAN
Dial-up router
Web Monitoring
Data management
Web Monitoring
Office
ServerWeb Monitoring
Maintenance department
Printer for data form

FX100 Specification
Input section
Measurement points: FX103 3 (three) channels
FX106 6 (six) channels
FX112 12 (twelve) channels
Measurement interval: FX103 250 ms
Input Types DCV:20mV, 60mV, 200mV, 2V, 6V, 20V, 50V
FX106, FX112 1s, 2s
TC: R, S, B, K, E, J, T, N, W, L, U, WRe
RTD:Pt100, JPt100 (Pt1000: Optional)
DI: voltage input (TTL), contact input
DCA:with external shunt register
Simple Calculation: Differential, linear scaling, square root
Maximum allowable input voltage:
±10 VDC (continuous) for less than 200mVDC range, TC, RTD, DI
ranges
±60 VDC (continuous) for more than 2 VDC range
Maximum common mode noise voltage:
Maximum noise voltage between channels:
250 Vrms AC (50/60Hz)
250 Vrms AC (50/60Hz)
Display
Display: 5,5“ TFT color-LCD
Display types: Trend, bar graph, digital, overview, historical,
information (alarm, message, memory)
Language: English, French, Germany, Japanese
Data Storage Function
Internal memory: Flash memory
External media: One of the following external media options can be specified:
Saving method: Automatic saving or manual saving
- None, - 3,5“ floppy disk, - compact flash memory card (32MB-512MB)
Data type: Display data, event data
Data format: Binary format
Alarm Function
Number of levels: 4 levels per channels
Type of alarm: Higher/lower limits, differential higher/
lower limits, rate-of-change rising/falling limits
Construction
Dimensions: 144(W) x 144(H) x 234(D) mm
Weights: FX1xx-0: approximately 2.2 kg
FX1xx-1: approximately 2.5 kg
FX1xx-4: approximately 2.3 kg
Front panel: Water and dust proof (based on IEC529-IP65, except external icing
test, except for side-by-side mounting)
Suffix
code
-1
-4
Option
code
FX100(3ch)
FX100(6ch)
FX100(12ch)
None
FDD (3.5 inch, 1.44MB)
Compact flash memory card(32MB)
English (German/French)
Alarm output 2 points *
Alarm output 4 points *
/A2
Alarm output 6 points *
/A3
RS-232 communication interface *
/C2
RS-422-A/485 communication interface *
/C3
Ethernet(10BASE-T) communication interface
/C7
FAIL/memory end output *
/F1
Mathematical function (with report function)
/M1
3 legs isolated RTD
/N2
Pt1000Ω input
/N3
Pulse input 3 points, remote control 5 points (including Mathematical function )*
/PM1
Remote control 8 points
/R1
1
1
1
2
2
3
Model Description
FX103
FX106
FX112
External memory -0
Display Language -2
Option /A1
*1: /A1, /A2, /A3 cannot be specified together.
*2: /C2, /C3 cannot be specified together.
*3: If /F1 is specified, /A3 cannot be specified.
*4: If /PM1 is specified, each /A3, /R1, and /M1 cannot be specified.
*4: If /PM1 is specified, /A2 and /F1 cannot be specified together.
In case that Modbus master function is utilized, either /M1 or /PM1 must be specified.
The TCP/IP software used in this product and the document for that
TCP/IP software are based in part on BSD networking software, Release 1 licensed from The
Regents of the University of California.
• Ethernet is a registered trademark of XEROX Corporation.
• Modbus is a registered trademark of AEG Schneider
• Other company and/or product names are registered trade mark of their manufactures.
Power Supply
Rated voltage: 100 to 240 VAC
Rated frequency: 50/60 Hz
Power consumption: normal 22 VA, maximum 35 VA
Safety and EMC Standards
Safety standards: Certified by CSA22.2 No.1010-1, UL61010B-B complies with
EMC standards: Complies with EN61326-1
EN61010-1
Optional Pulse Input Functions (/PM1)
Number of channels: 3 for pulse, and 5 for remote controlling
Applicable frequency: Up to 100 Hz
Minimum pulse width detection:
Low (close), high (open) : more than 5ms
Optional Relay Output (/A1, /A2, /A3)
Number of outputs: 2,4,or 6 points; energized/
di-energized, hold/non-hold, AND/OR
Optional Serial Communication functions (/C2, /C3)
Connection: EIA RS232 (/C2) or RS-422-A/485 (/C3)
Protocols: Yokogawa private protocol
Modbus function: MODBUS RTU MASTER/ SLAVE
Optional Ethernet Communication functions (/C7)
Connection: Ethernet (10Base-T)
Functions: E-mail notification, Web-server, FTP function
Optional Mathematic Functions (/M1)
Number of channels: Up to 12 channels
Operations:
General arithmetic operations:
Four arithmetic operations, square root, absolute, common
logarithm, exponential, power, relations, logic operations.
Statistical operations: Average, minimum, maximum, and summation
Constant: Available (up to 30 constants)
Digital data input via communication:
Report function:
Up to 12 data
Type: Hourly, daily, hourly+daily, daily+weekly, daily+monthly
Operation: Average, maximum, minimum, summation
Data format: ASCII
Optional Remote Controlling Functions (/R1)
Number of channels: 8 points
Operable items: Memory start/stop, computation start/stop, computation data reset,
alarm acknowledgement, event file external trigger, message writing,
load setting, time setting, snapshot.
(2.30)
58.4
0
+0.4
Unit : mm
(approx. inch)
9.4
(0.37)
(min. space for mounting)
Option Terminal
(5.37)
Input Terminal
136.5
1 to 12ch
7.5
(0.30)
(dimension after mounting)
RS-232 or RS-422A/485
STYLE
SUFFIX
MODEL
FREQUENCY
NO.
SUPPLY
10Base-T
SDBSDA RDBRDA
RS-422A/485
FGSG
151.5 (5.96)
144.3 (5.68)
4
(0.95)
144.3 (5.68)
151.5 (5.96)
24.1
175 (6.89)
2 to 26 (panel thickness)
NOTICE
● The mounting hardware is attached on both sides or at the top and
bottom (2places) for panelmounting.
● See the general speelfication sheet (GS 04N03A01-00E) for the panel
cutout for
side by side or top-and bottom mounting.
Ethernet
Power Supply
Terminal
YOKOGAWA ELECTRIC CORPORATION
Network Solutions Sales Business Div.
/Phone: (81)-55-243-0309, Fax: (81)-55-243-0397
E-mail: tm@csv.yokogawa.co.jp
YOKOGAWA CORPORATION OF AMERICA Phone: (1)-770-253-7000, Fax: (1)-770-251-2088
YOKOGAWA EUROPE B.V. Phone: (31)-33-4641806, Fax: (31)-33-4641807
YOKOGAWA ENGINEERING ASIA PTE. LTD. Phone: (65)-62419933, Fax: (65)-62412606
Subject to change without notice.
[Ed : 01/b] Copyright ©2003
Printed in Japan, 310(YG)
RS-12E