Atec FW-Bell-5080 User Manual

Hall Effect Gaussmeters
Description
The 5000 Series Hall effect portable gaussmeters represent the latest design from the world leader in magnetic measuring equipment. F.W. Bell’s exclusive Dynamic Probe Correction allows measurements from 0 to 30 kG with a basic accuracy of 1%.
Key features include Auto Zero, Min./Max./Peak Hold, Auto Range and Relative Mode. All models allow the user to select Gauss or Tesla readings. The Model 5080 also has a selection for readings in Ampere/Meters and features a corrected analog output (± 3 V F.S.) and an RS­232 communications port.
The 5000 Series Hand-Held Gaussmeters’ built-in software eliminates the need for complex calibration procedures. User prompts on the custom formatted LCD allow fast, simple push button operation. All models come equipped with a detachable transverse probe, zero gauss chamber, instruction manual, hard carrying case and two 9 volt batteries. Axial and other style probes are available as options.
Applications for the 5000 Series range from the most sensitive laboratory environment to the most rugged industrial setting. All instruments are CE compliant.
Features
5000 Series Hand-Held Gaussmeters
0605ledoM 0705ledoM 0805ledoM
dedulcnIeborP
oreZotuA
dloHxaM/niM
SMReurT
egnaRotuA
dloHkaePeurT
edoMevitaleR
)golana(stuptuO
troPnoitacinummoC
Sypris Test & Measurement, Inc. • 6120 Hanging Moss Road • Orlando, Florida 32807 • Phone (407) 678-6900 • Fax (407) 677-5765 • www.fwbell.com
5000 Series Specifications
General Information
Hall Effect Gaussmeters
Bell Technologies Inc. a SYPRIS company • 6120 Hanging Moss Road • Orlando, Florida 32807 • Tel.: (407) 678-6900 • Fax: (407) 677-5765 • www.fwbell.com
Due to continuous process improvement, specifications subject to change without notice.
Probes and Accessories
Model 5060 5070 5080
Basic Accuracy 4% 2% 1% Frequency Bandwidth dc dc - 10 kHz dc - 20 kHz Sampling Rate (dc Mode)
10/sec 10/sec 10/sec
Ranges
Low Range Mid Range High Range
(2)
2 kG
-
20 kG
(3)
200 G
2 kG
20 kG
(3)
300 G
3 kG
30 kG
Resolution
Low Range Mid Range High Range
1.0 G (100 mT)
-
10 G (1 mT)
0.1 G (10 mT)
1.0 G (100 mT) 10 G (1 mT)
0.1 G (10 mT)
1.0 G (100 mT) 10 G (1 mT)
Display LCD LCD LCD Digits
3 3 3
Readings Gauss
Tesla
Gauss
Tesla
Ampere / Meters
Gauss
Tesla
Ampere / Meters
Analog Output --
±
3V F.S.
Communication Port
--RS-232
Model All
Temperature
Operating Storage
0°C to +50°C
Power
two 9V batteries
Size
Length x Width x Height 5.2 (132 mm) x 5.3 (135 mm) x 1.5 (38 mm)
Model Number Description Item Number
Model 5080 Probes
STD58-0404 STD58-0402 SAD58-1904 SAD58-1902
4 Transverse Probe (Std. w meter) 2 Transverse Probe 4 Axial Probe 2 Axial Probe
125804 125803 125802 125801
Model 5070 Probes
STH57-0404 STH57-0402 SAH57-1904 SAH57-1902
4 Transverse Probe (Std. w meter) 2 Transverse Probe 4 Axial Probe 2 Axial Probe
125704 125703 125702 125701
Model 5060 Probes
HTV56-0602 STV56-0404 STV56-0402 SAV56-1904 SAV56-1902
2 H.D. Transverse Probe (Std. w meter) 4 Transverse Probe 2 Transverse Probe 4 Axial Probe 2 Axial Probe
125605 125604 125603 125602 125601
Meter Accessories
X-5000-0006 YA-111 PSU-15 PSR-15
6 ft. Extension Cable Zero Gauss Chamber AC Adapter, 110V AC Adapter, Switching
125000 122920 145012 115001
Due to continuous process improvement, specifications subject to change without notice.
-25ºC to +70ºC
®
1/2 1/2 3/4
6120 Hanging Moss Road • Orlando, Florida 32807
Phone (407) 678-6900 • Fax (407) 677-5765 • www.fwbell.com