Atec FPW55 User Manual

Product data sheet
FPW55-SL Ultra-Low Refrigerated-Heating Circulator
Superior models for most demanding applications
JULABO Ultra-Low Refrigerated Circulators for heating and cooling are suitable for external temperature tasks. Powerful circulating pump systems and high heating and cooling capacities guarantee short heat-up and cool-down times. ACC ‘Active Cooling Control‘ provides active cooling control across the whole temperature range. An energy saving feature with only minor loss of heat is provided by the proportional cooling capacity control in the ‘FP’ refrigeration units. The inevitable dust accumulation that occurs in refrigeration systems is solved by means of an easily removed venting grill, which allows for easy cleaning. The units are equipped with handles or castors for an easy transportation. All models have a drain tap on the front allowing the fluid to be drained easily. Additionally the instruments are equipped with an improved insulation to help avoid ice-formation, and have a visual liquid level display.
Your advantages
VFD COMFORT DISPLAY LCD DIALOG DISPLAY backlit for convenient interactive operation Keypad for setpoints, warning/safety values and menu functions ICC (Intelligent Cascade Control), self-optimizing temperature control TCF Temperature Control Features to optimize the control behaviour ATC3 3-Point-Calibration Pt100 External sensor connection for measurement and control SMART PUMP, electronically adjustable pump stages Early warning system for low liquid level (DBGM 203 06 059.8) Adjustable high temperature cut-out, visible via display RS232/RS485 interface for online communication Integrated programmer for 6 x 60 program steps Connections for solenoid valve and HSP booster pump Proportional cooling control Active Cooling Control
Technical Data
Order No. 9352756 Model series HighTech Category Ultra-Low Refrigerated-Heating Circulators Working temperature range (°C) -60 ... 100 Temperature stability (°C) ±0.05 Setting / display resolution 0.01 °C Integrated programmer 6x60 steps Temperature Display VFD
LCD
Heating capacity (kW) 3 Cooling capacity (Medium Ethanol) °C 20 0 -20 -40 -60
kW 5.5 4.1 2.2 1 0.13 Pump capacity flow rate (l/min) 22-26 Pump capacity flow pressure (psi) 5.8-10.2 Pump capacity flow suction (psi) 2.9-5.8
Product data sheet
Pump connections M16x1 Barbed fittings diameter (inner dia. / mm) 8 / 12 Filling volume liters 27 Refrigerant R404A External Pt100 sensor connection integrated Digital interface RS232, RS485, Optional Profibus Ambient temperature 5...40 °C Dimensions W x L x H (inch) 23.2 x 29.9 x 45.7 Weight (LBS) 423 Classification according to DIN12876-1 Classification III (FL)according to DIN 12876-1 Included with each unit 2 each barbed fittings for tubing 8 and 12 mm inner dia.
(pump connections M16x1 female). Cooling water
connection G 3/4" male with barbed fittings for tubing 1/2"
inner dia. Cooling of compressor Water Power requirement V / Hz / A 3x 230/60/31
Available voltage versions
400 V / 3 Ph. / 50 Hz 230 V / 3 Ph. / 60 Hz
Characteristics
A perfect view
Ample, easy to read VFD Comfort display for simultaneous display of 3 values, warning functions, high temperature cut-off, pump stages (resolution 0.01 °C)
Pump stage and liquid level
Backlit indicator for selected pump stages and filling volume on Presto® PLUS, Magnum 91 & Forte HT
For perfect results
Intelligent Cascade Control’, automatic & self optimizing adjustment of PID control parameters, temperature stability ±0.005 °C internal, <±0.05 °C external
Highest measuring accuracy
Absolute Temperature Calibration’ for manual compensation of a temperature difference, 3-point calibration
Control from the external application
External Pt100 sensor connection for precise measurement and control directly in the external application
Additional plain text information
Comfortable LCD dialog display for interactive operation with plain text display
Comfortable and detailed
Comfortable keypad with additional menu functions for pump stages, calibration, control parameters, programmer, warnings, etc.
Full control
Temperature Control Features’ for individual optimization, access to all important control parameters, additional settings for band limit, limits, Co-Speedfactor etc.
Clever pump system
Reliable and consistent pump capacity, electronically adjustable pump stages
Connection compliant to standard
RS232/RS485 dual-interface for serial data transmission according to EIA-485 industry standard (2-wire bus technology), upgradable with Profibus DP
Optimal program control
For the execution of time and temperature dependant profiles, 6 temperature profiles with 60 steps max., with real time clock
Automatic control of operating time
Electronic countdown-timer function for timer-programmed unit shut-down, standby mode after programmed time expires
Loading...