1 / 2
The FP-COMB 32 coupling/decoupling network – for
Surge Combination Wave, Ring Wave and EFT/Burst –
is fully compliant with the standard requirements of
IEC/EN 61000-4-4, IEC/EN 61000-4-5 and IEC/EN
61000-4-12.
The FP-COMB 32 is controlled by the AXOS5 / AXOS
8
expandable immunity test system(s). The CDN
automatically changes the coupling paths, phase
angles and source impedance based on test
parameters set by the user via the AXOS controller –
depending on the standard and coupling mode.
The FP-COMB 32 was designed to reduce residual
voltage levels at the EUT mains input by integrating the
proper decoupling inductors for each type of CDN
application in order to meet the requirements (with
regard to voltage drop at the rated current). Apart from
covering the EN/IEC 61000-4-5 standard, the FPCOMB 32 also covers tests to meet surge
requirements outlined in ANSI/IEEE C62.41.
FEATURES
Surge Combination Wave, 1.2/50us - 8/20us
Ring Wave, 100kHz
Electrical Fast Transient (EFT) / Burst
7kV impulse voltage for Surge Combination Wave
and Ring Wave
5kV impulse voltage for EFT/Burst
Line voltage 480V AC / DC phase-to-phase
32A EUT current per phase
Phase angle synchronization for each path
BENEFITS
Combined CDN for Surge Combination Wave,
Ring Wave and EFT/Burst
LEDs indicate active mode and coupling path
Automatic selection of Surge impedance
Fully remote controlled by AXOS
5
/ AXOS8
APPLICATIONS
Single & three phase power line systems
IEC 61000-4-4 Edition 3
IEC 61000-4-5 Edition 3
IEC 61000-4-12
ANSI C62.41 & C62.45 power lines
Many IEC & EN product standards
Qty. 1 FP-COMB 32
Qty. 1 AC mains cable country specific
Qty. 1 EUT mains cable 32A
Qty. 1 EUT mains adapter 32A
Qty. 1 Calibration certificate
Qty. 1 Surge cable to AXOS
Qty. 1 EFT/Burst cable to AXOS
Qty. 1 User’s manual
FP-COMB 32
COMBINED AUTOMATIC 3-PHASE COUPLING / DECOUPLING NETWORK
1 / 2
Banana socket front panel
Banana socket front panel
EFT/Burst
Surge Combination Wave
Ring Wave
IEC/EN 61000-4-4 Ed. 3
IEC/EN 61000-4-5 Ed. 3
IEC/EN 61000-4-12 Ed. 2, C 62.41
Maximum EFT/Burst Input Voltage
Maximum Surge Combination Wave
Input Voltage
7kV
Maximum Ring Wave Input Voltage
7kV Coupling Path Selection
10V to 480V input voltage
0° to 359°, step 1°
Sync. on coupling path,
output BNC rear panel
Up to 480V AC
16.7Hz, 50Hz, 60Hz
EFT/Burst Input Voltage Range
Surge Combination Wave Input
Voltage Range
0.2kV - 7kV
Ring Wave Input Voltage Range
10V to 480V input voltage
0° to 359°, step 1°
Extension Connector
(37 pol. Sub-D connector)
Indication of coupling path Power ON LED
CDN active LED
Europe
Haefely Test AG
Birsstrasse 300
4052 Basel
Switzerland
China
Haefely Test AG Representative Beijing Office
8-1-602, Fortune Street
No. 67, Chaoyang Road, Chaoyang District
Beijing, China 100025
North America
Hipotronics, Inc.
1650 Route 22 N
Brewster, NY 10509
United States
+ 41 61 373 4111
+ 41 61 373 4912
sales@haefely.com
+ 86 10 8578 8099
+ 86 10 8578 9908
sales@haefely.com.cn
+ 1 845 279 3644
+ 1 845 279 2467
sales@hipotronics.com
TECHNICAL SPECIFICATIONS
HAEFELY HIPOTRONICS has a policy of continuous product improvement. Therefore we reserve the right to change design and specification without notice.
2 / 2