FLX380-30x FlexTester3 OTDR
Features
• 3rd generation hand-held, all-in-one OTDR, OLS, OPM, VFL
• Patented in- or out-of-service testing from a single port
• 41/41 dB dynamic range @ 1310/1550 nm
• Industry-leading 0.8/2.5/30 m event / attenuation / PON dead zones
• ServiceSafe™ live PON detection and OTDR test without service disruption
• Integrated OLS/OPM with Wave ID reduces test time 80% and eliminates setup errors
• Rugged, hand-held and lightweight (<1 kg)
• High-contrast display: clear and bright, even in direct sunlight
• Industry leading battery life: over 12 hours operation from a single charge
• It’s all about speed: with Instant On, you’re ready to test in <5 sec
Applications
• Certify new FTTx PON or point-to-point ber installations, including splice, splitter and
connector loss and reectance, end-to-end length, loss and optical return loss (ORL).
• Troubleshoot live FTTx PONs, including live PON detection and PON power
measurements plus live PON OTDR testing at 1625 or 1650 nm.
• Complete multi-wavelength end-to-end insertion loss tests faster and eliminate setup
errors using AFL’s Wave ID loss test feature.
• Generate stable optical source signals (CW, Wave ID or ber-identifying tones) using the
integrated Optical Laser Source.
• Trace bers or locate ber bends or breaks using the VFL (visible red laser).
The NOYES FLX380 FlexTester3 is the world’s smallest, lightest, most complete single mode ber optic test set. It combines highperformance, multi-wavelength OTDR / PON OTDR, OLS, OPM, VFL and PON Power Meter in a rugged, hand-held package.
With 41 dB dynamic range, best-in-class event, attenuation, and PON dead zones, macrobend and splitter detection, launch quality
check, plus AFL’s unique ServiceSafe and Wave ID features, the FLX380 FlexTester3 Series offers an unmatched combination of optical
test functions, ease-of-use, portability, and value. FlexTester3 Series is offered in four models to best suit your application requirements:
• FLX380-304: Verify both in-service (live) and out-of-service FTTx networks from a single port. Includes 1310/1550/1650 nm live PON
OTDR with integrated PON Power Meter.
• FLX380-303: Similar to FLX380-304, but with 1625 nm ltered Live PON OTDR, instead of 1650 nm.
• FLX380-302: Complete out-of-service testing at all FTTx PON wavelengths (1310/1490/1550 nm).
• FLX380-300: Lowest cost, high-performance, all-in-one 1310/1550 nm OTDR for out-of-service installation testing or troubleshooting
on both FTTx PON and point-to-point ber optic networks.
• All models include integrated VFL plus Wave ID source and power meter.
Over 1000 OTDR test results (Telcordia SR-4731 .SOR le format) may be saved in the FLX380’s internal 4GB memory. Stored OTDR
and OPM results may be transferred to PC via USB cable or wirelessly via Bluetooth®. Windows® compatible TRM® 2.0 Basic Test
Results Manager software is included for OTDR and OPM results viewing, analysis, and professional report generation.
www.AFLglobal.com or (800) 321-5298, (603) 528-7780
1
© 2013, AFL, all rights reserved. FLX3-3X-2000 Revision 1C 2013-09-30
Specications are subject to change without notice.
FLX380-30x FlexTester3 OTDR
ServiceSafe™ Testing on Live PONs
In FTTx PONs, it is possible for one user to lose service while other subscribers served by
the same OLT continue to remain in service. Attempting to troubleshoot a faulty optical
distribution and drop ber connection from the out-of-service subscriber’s location using
a 1310 or 1550 nm OTDR, would disrupt service to remaining users. AFL’s patented
ServiceSafe feature alerts the OTDR user to the presence of live trafc and prevents
the initiation of service-disrupting OTDR tests at 1310 or 1550 nm. FLX380-303 and
-304 models additionally measure downstream power levels at 1490 and/or 1550 nm,
and allow the user to initiate an OTDR test using a non-disruptive 1625 or 1650 nm
wavelength. To eliminate unnecessary connector wear and tear, 1625/1650 nm live PON
OTDR testing and PON power measurements are performed through the same optical
port used for 1310/1550 OTDR testing (US patent 8,411,259).
Fast, error-free Loss Tests using Wave ID
All FLX380s integrate an Optical Laser Source (OLS) and Optical Power Meter (OPM)
supporting AFL’s unique Wave ID capability. With Wave ID, the OPM automatically
synchronizes to a single or multi-wavelength Wave ID optical signal sent by another
FLX380, OFL280, or NOYES hand-held OLS connected to the other end of the link. The
OPM automatically determines which wavelengths are sent and measures power and
loss at each wavelength. There is no need for the OPM user to coordinate wavelength
settings with the OLS user at the other end, saving signicant test time and eliminating
setup errors.
The integrated OLS and OPM also generate and detect ber-identifying tones to enable
positive ber identication before disconnecting bers during maintenance.
OPM results may be saved using the same le-naming convention applied to OTDR
results. Saved OPM results may be recalled and viewed or uploaded to TRM
for report generation.
Create Professional Test Reports using TRM® 2.0
Stored OTDR and/or OPM results can be uploaded via USB to a PC, then viewed and
analyzed using TRM 2.0 Basic Test Results Manager software included with each
FLX380 FlexTester3. With TRM, users can generate professional acceptance test reports
conforming to industry guidelines. TRM allows users to create customized cover pages
with their company logo along with results pages showing dual wavelength traces,
event tables, event map, and loss results for each ber. A report generation Wizard
makes custom report generation fast and easy.
TRM also supports OTDR trace analysis providing batch editing features, event add,
modify, or delete, trace compare, and advanced event analysis capabilities. Upgrade to
TRM 2.0 Advanced to add bi-directional trace averaging.
www.AFLglobal.com or (800) 321-5298, (603) 528-7780
2
© 2013, AFL, all rights reserved. FLX3-3X-2000 Revision 1C 2013-09-30
Specications are subject to change without notice.