Atec Fluke-789 User Manual

Technical Data
New
Fluke 789
ProcessMeter
1000V CAT III
Designed and Conforms to
IEC 1010-1
LISTED
950 Z
R
N10140
These 787 features are also included in the 789
DMM designed to meet 1000 volt IEC 1010 CAT III standards
Precision 1000 V, 440 mA True-rms digital multimeter
Frequency measurement to 20 kHz
Min/Max/Average/Hold/Relative modes
Diode Test and Continuity Beeper
Simultaneous mA and % of scale readout
20 mA dc current source / loop calibrator / simulator
Manual Step (100 %, 25 %, Coarse, Fine) plus Auto Step and Auto Ramp
Externally accessible battery for easy battery changes
Key new features of the Fluke 789
24 V Loop power supply
HART mode setting with loop power (adds 250 ohm resistor)
100 % larger dual display
1200 ohm drive capability on mA source
Enhanced backlight with two brightness settings
0-100 % mA Span Check buttons to toggle between 4 and 20 mA
Infrared I/O serial port compatible with FlukeView®Forms Software Version 2.1 (available Feb. 2003)
Externally accessible fuses for easy replacement
Double your power.
The Fluke 787 ProcessMeter was the first tool to combine a loop calibrator with a DMM to give process techni­cians double the power in one tool. Now it’s even better – the ultimate loop calibration multimeter – the Fluke 789 ProcessMeter.
The 789 has a display that’s not only twice as large, but also twice as bright with two levels of backlighting. And with its built-in, selectable 250 ohm HART
®
resistor, it eliminates the need to carry a separate resistor with you.
Now process technicians can do a
lot more while carrying a lot less.
Measurement Function Range and Resolution
Best Accuracy
(% of reading + LSD)
V dc 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V 0.1 % + 1 V ac (true-rms) 400.0 mV, 4.000 V, 40.00 V, 400.0 V, 1000 V 0.7 % + 2 mA dc 30.000 mA .05 % + 2 A dc 1.000 A (0.440 A continuous) 0.2 % + 2 A ac 1.000 A (0.440 A continuous) 1 % + 2 Resistance 400.0 Ohms, 4.000 k, 40.00 k, 400.0 k, 4.0 M, 40 M 0.2 % + 1 Frequency (0.5 Hz to 20 kHz) 199.99 Hz, 1999.9 Hz, 19.999 kHz .005 % + 1 Diode Test 2.000 V (shows diode voltage drop) 2 % + 1 Continuity Beeps for resistance < approx. 100 ohms
Fluke Corporation
PO Box 9090, Everett, WA USA 98206 Fluke Europe B.V.
PO Box 1186, 5602 BD Eindhoven, The Netherlands
For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa (31 40) 2 675 200 or Fax (31 40) 2 675 222 In Canada (800) 36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: http://www.fluke.com/
©2002 Fluke Corporation. All rights reserved. All copyrights are the property of their respective owners. Printed in U.S.A. 10/2002 1999242 D-E NG-N Rev C
Fluke. Keeping your world
up and running.
General specifications
Maximum voltage applied between any jack and earth ground:
1000 V RMS
Storage temperature: -40 °C to 60 °C Operating temperature: -20 °C to
55 °C Temperature coefficient: 0.05 x (speci-
fied accuracy) per °C (for temperatures < 18 °C or > 28 °C)
Relative humidity: 95 % up to 30 °C; 75 % up to 40 °C; 45 % up to 50 °C; 35 % up to 55 °C
Vibration: Random, 2 g, 5-500 Hz Shock: 1 meter drop test Safety: Designed in accordance with
EN61010, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No. 1010..1-92 Over-voltage Category III
Size: 50 mm H x 100 mm W x 203 mm L (1.97 in H x 3.94 in W x 8.00 in L)
Weight: 600 g (1.3 lbs) Battery: Four AA alkaline batteries Battery life: 140 hours typical
(measurement), 10 hours typical (sourcing 12 mA)
Warranty: 3 years
Output Function Range and Resolution
Drive Capability Accuracy
(% of span)
DC Current Output 0.000 to 20.000 mA or 4.000 to 20.000 mA 24 V compliance,
(selectable at power-up) or,
.05 %
(Internal battery operation) Over-range to 24.000 mA 1,200 Ohms,
@ 20 mA
DC Current Simulate 0.000 to 20.000 mA or 4.000 to 20.000 mA, 1000 Ohms,
(selectable at power-up) @ 20 mA .05 %
(Ext. 24 Volt loop supply) Over-range to 24.000 mA 24 V Loop Supply Minimum 24 V 250 Ohms
> 24 V
@ 20 mA
Current Adjustment Modes Manual: Coarse, Fine, 25 % and 100 % step
Automatic: Slow Ramp, Fast Ramp, 25 % step
Temperature range of 18 °C to 28 °C, for one year after calibration
Optional accessories
80T-IR Infrared Temperature Probe 80TK Thermocouple Module 80T-150U Universal Temperature Probe TL20 / TL22 / TL24 / TL26 / TL28 /
TL40A Test Lead Sets AC20 / AC80 Clips TP20 Industrial Test Probes 80i-400 AC Current Clamp* i-410 AC/DC Current Clamp** i-1010 AC/DC Current Clamp** C25 / C100 Cases 80K-6 and 80K-40 High Voltage Probes 85RF High Frequency Probes PV350 Pressure Vacuum Module Fiber Optic Meter FOM LPAK80-4 LockPak TPAK ToolPak Meter Hanging Kit
*Above 50 A ac **Above 1 A dc or 20 A ac
Ordering information
Model
Fluke-789 ProcessMeter
Including: TL71 Premium Test Lead Set plus AC72 Alligator Clips, Four AA alkaline batteries (installed), Users Manual and Quick Reference Guide
Loading...