Fluke 772 and 773
Milliamp Process
Clamp Meters
mA measurements
without breaking
the loop.
Save time.
Save money.
Technical Data
Use the Fluke 772 and 773 to:
Measure 4 to 20 mA signals without ”breaking the
•
loop” just like the innovative and popular Fluke 771
Process Milliamp Clampmeter
Source 4 to 20 mA signals for testing control
•
system I/O or I/Ps
Simulate 4 to 20 mA signals for testing control
•
system I/O
Measure 4 to 20 mA signals with in-circuit
•
measurement
Simultaneously measure mA in-circuit with 24 V
•
loop power for powering and testing transmitters
Source mA output signals in a linear ramp or 25 %
•
step output
– Automatically change the 4 to 20 mA output for
remote testing
Power saving features, auto-off, backlight timeout
•
extend battery life
Fluke 773 features:
DC voltage measurement to verify 24 V power
•
supplies or voltage I/O signals
Source dc voltage to test input devices that accept
•
a 1 to 5 volt or 0 to 10 volt signal
Scaled mA output provides a continuous mA signal
•
that corresponds to the 4 to 20 mA signal measured
by the mA clamp
– Output mA signal enables a logging DMM (289)
or other device to record the 4 to 20 mA signal
without breaking the loop
mA in/out: simultaneously measure the mA signal
•
with the clamp and source a mA signal
– Apply a mA input signal to a device and measure
its’ 4 to 20 mA output on devices such as valves
or mA isolators
Voltage output linear ramp or 25 % step output
•
– Automatically change the voltage output for
remote testing
Functions
mA measure
w/jaw
7 71
772
773
Functional specifications
771, 772, 773 mA measurement
772 and 773 mA measurement 0 to 24.00 mA 0.2 % + 2 counts
772 and 773 mA source 0 to 24.00 mA 0.2 % + 2 counts
772 and 773 mA simulate 0 to 24.00 mA 0.2 % + 2 counts Maximum voltage 50 V dc
773 Voltage source 0 to 10.00 V dc 0.2 % + 2 counts 2 mA maximum drive current
773 Voltage measure 0 to 30.00 V dc 0.2 % + 2 counts
•
• • • • •
• • • • • • • • •
mA measure
In circuit mA source mA sim
Function Resolution and range Accuracy Notes
0 to 20.99 mA 0.2 % + 5 counts
21.0 mA to 100.0 mA 1 % + 5 counts
Loop power
24 V
DCV source
0-10 V
DCV
measure
0-30 V
Scaled mA
output to mA
input mA in/out
Measured by clamp
Measured in series with test
jacks
Maximum mA drive: 24 mA into
1,000 ohms
General specifications 772 and 773
Influence of earth’s field < 0.12 mA
Battery (4) 1.5 V, Alkaline, IEC LR6
Working hours 12 hours @ 12 mA source into 500 ohms
Size (HxWxL) 772, 773: 41.3 mm x 76 mm x 248 mm (1.625 in x 3 in x 9.75 in)
Weight 772, 773: 415 g (14 oz) 771: 260 g, (9.1 oz)
Operating temperature -10 °C to 50 ºC
Storage temperature -25 °C to 60 °C
Operating humidity < 90 % @ < 30 °C; < 75 % @ 30 ~55 °C
Operating altitude 0 ~ 2,000 m
Storage altitude None
IP rating IP 40
Vibration requirements Random 2 g, 5 Hz to 500 Hz
Drop test Passes 1 meter drop test (except the jaw)
EMI, RFI, EMC
Temperature coefficients 0.1(/°C x specified accuracy for temperature < 18 °C or > 28 °C)
Warranty Three-years, one-year on mA clamp assembly and cable
771: 59 mm x 38 mm x 212 mm, (2.32 in x 1.5 in x 8.35 in)
Meets applicable requirements in EN61326-1 Note: For current
measurement w/jaw, add 1 mA to specification for EMC field strengths
of 1 V/m up to 3 V/m
(see www.fluke.com/771 for more information on the Fluke 771 specifications)
Ordering information
Fluke-772 Milliamp Process Clamp Meter
Fluke-773 Milliamp Process Clamp Meter
Included accessories
Soft carrying case, test leads, alligator clips, hanging
strap and user’s manual.
772 773
2 Fluke Corporation 772 and 773 Milliamp Process Clamp Meters
Fluke. Keeping your world
up and running.
Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A.
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa +31 (0) 40 2675 200 or
Fax +31 (0) 40 2675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com
©2009 Fluke Corporation. Specifications subject to
change without notice. Printed in U.S.A.
5/2009 3442293 D-EN-N Rev B
Modification of this document is not permitted
without written permission from Fluke Corporation.
®