Unless otherwise stated, WAN interfaces provide two input ports and two
output ports allowing any one of the following connection configurations to
be used:
Terminal Mode - uses one input and one output
Bridged Monitor Mode - uses both inputs and outputs for bi-directional
monitoring at test access points; a high input impedance should normally be
selected
Jack Monitor Mode uses both inputs only for bi-directional monitoring at
protected monitor points
Through Monitor Mode (Drop and Insert Mode) - uses both inputs and
outputs providing bi-directional repeater and monitoring functionality. Each
receiver input is terminated. The insert mode can place test traffic like SLA,
PING, LMI emulation, Traffic Generation and Simulation.
The operation of the physical interface is often critical in determining the
cause of network problems. Therefore, the Advisor tracks errors at the
physical layer, and it stamps the information with a 1 ms time stamp. Signal
events are recorded on the display for both the line (network) side as well as
the equipment (user/subscriber) side. The time of the last occurrence of a
particular event is recorded as well. Events are saved in the buffer and can be
logged to disk.
Line status is displayed in real time. All of the events listed in the Physical
layer alarms and statistics section for each interface below are saved in the
buffer and counted in the line status display. These events may be logged to
disk. Critical parameters marked with an asterisk (*) are also displayed in
large green or red boxes in the line status display for easy at-a-glance
viewing.
TT
11
//
DSDS
11
((
11
..
55
44
44
MM
bb
//
s)s)
JJ
22
22
99
88
BB
a a
nn
dd
J J
22
22
99
99
T
1
/
DS
1
(
1
.
5
4
4
M
b
/
s)
J
2
2
9
8
B
a
n
TT
11
//
DSDS
11
((
11
..
55
44
44
MM
bb
//
s)s)
JJ
22
22
General
This interface comprises a choice of two plug-in modules (J2298B and J2299B)
suitable for plugging into the J2300C/D Advisor mainframe and the J2900A
High Speed undercradle. The J2298B has RJ-48C connectors and the J2299B
has RJ-45 connectors. These modules handle cell and frame-based
technologies, i.e. ATM, Frame Relay, ISDN, HDLC, X.25, PPP, and BERT. These
interfaces do not support Frame Relay CIR and SLA measurements.
Common to Inputs and Outputs:
Connectors:
J2298B: balanced 100 Ohm RJ-48C and WECO mini-Bantams
J2299B: balanced 100 Ohm RJ-45 and WECO mini-Bantams
Line Code:
ATM: B8ZS
WAN: B8ZS, AMI
Framing:
ATM:
Extended Super Frame (ESF)
WAN:
Extended Super Frame (ESF)
D4 (Super Frame) Ft and Fs, or Fs only
Fractional, any multiple of 56 kbps or 64 kbps channels
Unframed 1.544 Mbps
Cell Mapping:
Direct (normal mode, ITU-T G.804) and PLCP (obsolete mode)
Cell Scrambling:
Conforms to ITU-T I.432.1 (x
d
99
88
BB
a a
nn
dd
43
+ 1) and may be turned on or off
BB
J
2
2
9
9
B
J J
22
22
99
99
BB
2727
27
2727
Inputs:
Two ports
Interface types (and input sensitivities):
DSX-1 (+6 dB to 10 dB ) and Network Interface (+6 dB to -36 dB )
Monitor modes:
Terminated (100 Ohm)
Bridged (High Impedance)
Monitor Jack
Physical Layer Alarms and Statistics:
Loss of Signal (LOS)
Loss of Frame (LOF)
Loss of PLCP Synchronization (LOPS)
Alarm Indication Signal (AIS)
Remote Alarm Indication (RAI)/Yellow
Bi-polar violations
Extended Super-Frame (ESF) CRC errors
Line code violation
Frame slips
Frame bit errors
Ones density violations
Excess zeros
ATM Layer Statistics:
Average utilization in percent
Instantaneous utilization in percent
Total cells received
Idle/unassigned cells received
Busy (assigned) cells received
Header (HEC) errors
Capture buffer size: 28 Mbyte (approximately 400,000 cells)
Capture buffer timestamp resolution: 100 ns
Capture rate: Full line rate
Outputs:
Two ports, 100 Ohm balanced
RJ-11 handset jack (for WAN)
Interface types (and output levels):
DSX-1 (build-out selectable from 0 to 655 ft in 5 steps) and Network
Interface (selectable LBO levels, 0, -7.5 dB and -15.0 dB)
Electrical:
ITU-T G.703
Clocking:
Recovered (loop), Internal, and External (using other receiver input)
Internal clock rate accuracy:
+/- 32 ppm
Traffic Generation from cell table
Transmission of bit error rate (BER) patterns in the physical layer
frame payload or in the ATM cell payload:
1111, 1010, 1100, PRBS 2
15
- 1, PRBS 220 - 1, PRBS 223 1
Transmission of 64-bit BER user pattern in WAN
2828
28
2828