Atec Agilent-E6008B User Manual

E6000C Mini-OTDR
Technical Data Sheet
Specifications describe the instrument´s warranted performance, measured with typical PC-type connectors. Uncertainties due to the refractive index of fiber are not considered.
The following section contains both Specifications and Characteristics:
Specifications describe the instrument´s warranted performance.
Characteristics and typical data provide information about the non-warranted instrument
performance.
The Agilent Technologies E6000C Mini-OTDR is produced to the ISO 9001 international quality system standard as part of Agilent´s commitment to continually increasing customer
satisfaction through improved quality control.
Characteristics
Storage
Display
Horizontal Parameters
Start-km: 0 km to 400 km
Span: 0.1 km to 400 km
Readout resolution: 0.1 m
Minimum sample spacing: 4 cm
Refractive index: 1.00000 to 2.00000
Length unit: km, ft, or miles
Measurement points: up to 64000
Vertical Parameters
Vertical scale: 0.1 to 10.0 dB/Div
Read-out resolution: 0.001 dB
Reflectance range: –14 dB to –60 dB
Backscatter coefficient: 10 to 70 dB
at 1
µs
Pulsewidth
You can select any of the following pulsewidths:
10 ns, 30 ns, 100 ns, 300 ns, 1 µs, 3 µs, µs (all modules). You can also
and 10 select 5 ns for E6003C, 5A, 9A modules, and 20 E6003C, E6008B, and E6013A.
With the E6005A module, you can select a pulsewidth from 5 ns to 100 ns at 850 nm,
and from 5 ns to 10
With the E6009A module, you can select a pulsewidth from 5 ns to 100 ns at 850 nm,
and from 5 ns to 1
µs for E6003B,
µs at 1300 nm.
µs at 1300 nm.
3.5” floppy disk drive: for high density
720/1440 kByte floppy disks. MS-DOS format compatible. Reduced operating temperature of 5°C to 45°C, with 35% to 80% humidity at 40°C.
Memory Card: PCMCIA Type II.
440 MB with up to 13000 traces (typical with 64000 data points).
Internal memory: SRAM up to 2 MB.
Up to 300 traces(typical) with 4000 data points
OTDR Trace Formats
Trace format: compliant to the
following Bellcore/Telcordia OTDR trace formats:
GR 196, Revision 1.0
GR 196, Revision 1.1
SR-4731 Revision 2.0.
Trace Information: 5 comment labels
of up to 15 alphanumeric characters, and 5 comment fields of up to 41 alphanumeric characters are provided for each trace.
Real-time clock and date
Scan Trace
Type of events: reflective and non-
reflective.
Maximum number of events: 100.
Threshold for non-reflective
events: 0.0 to 5.0 dB, selectable in 0.01 dB steps.
Threshold for reflective events:
–14.0 to –65.0 dB, selectable in 0.1 dB steps.
Threshold for fiber breaks:
0.1 to 10 dB, selectable in 0.1 dB steps.
Color or monochrome VGA-LCD:
18.3 cm (7.2”)
Display points: 640 x 480 Points
Measurement update rate:
two measurements per second in refresh mode
Interfaces
RS232C:
Maximum transmission rate:
115200 bps Transmission time at 115200 bps for trace data: 4000 points at approx. 1 second; 64000 points at approx. 4 seconds.
Centronics: Standard parallel port
(SPP).
Keyboard: PS2 (Min-DIN). For English
Standard, PS2, or AT keyboard.
General
Automatic setup analysis
Instrument settings: storage and
recall of user-selectable instrument settings.
Laser safety class: All OTDR laser
sources specified by this data sheet are classified as Class 1M according to IEC 60825–1 (2001).
The Visual Fault Finder Sub-Module E6007A complies with Class 2 according to IEC 60825–1 (2001).
All laser sources comply with 21 CFR
1040.10 except for deviations pursuant to Laser Notice No. 50, dated 2001-July-26
Recommended module recalibration
period: 2 years. (OTDR Modules and Power Meter only)
Dimensions: 194 mm H, 290 mm W,
75 mm D (7.7” x 11.4” x 3.0”).
Fiber End Threshold: 0.1 to 20 dB,
selectable in 0.1 dB steps.
2
Weight: net < 2.9 kg (6.4 lbs), typical,
including battery pack and OTDR module.
Built-in Applications
Environmental
Automatic Multi Fiber Test
Pass/Fail Test
Fiber Break Locator
Power Meter / Loss Test mode
Visual Fault Finder mode
1
Optical Return Loss
End to End Loss
Easy OTDR
OTDR Training
OTDR Assistant
Operating Temperature: 0°C to 50°C
Storage Temperature: –40°C to +60°C
Humidity: 95% R.H from 0°C to 40°C
1
Power
AC: 100 – 240 Vrms ± 10% 5060 Hz
DC: 16 – 24 V
External Battery: NiMH
typically 8 hours continuous operation (minimum 4 hours) with Option #006. Charging time < 3 hours, non-operating
Low battery indicator
Battery charge status
1
The E6013A 1310/1550/1625 nm Mini­OTDR module does not have a slot available for E6006A Power Meter Sub-module or the E6007A Visual Fault Finder
3
Module Specifications / Characteristics
Specifications: Optical performance
Measured at 22°C
Module
Module E600
ModuleModule
Central Wavelength
Applicable Fiber single mode single mode
Pulsewidth 10 ns 100 ns
Dynamic Range1[dB]
Event Deadzone
Attenuation Deadzone
Module
Module E6003
ModuleModule
Central Wavelength
Applicable Fiber single-mode single-mode
Pulsewidth 10 ns 100 ns
Dynamic Range1[dB]
Event Deadzone
Attenuation Deadzone
± 3°C. Guaranteed specifications unless otherwise noted. Bold values are typical specifications
E6003333AAAA E6003
E600E600
1310
1310 nm
nm ± 25 nm/1550
13101310
nm nm
1550 nm
nm ± 25 nm 1310 nm
15501550
nm nm
1 µs 10 µs
10 ns 100 ns
1310 nm ± 25 nm/1550 nm
1310 nm 1310 nm
19/17 24/22 30/29 35/34 19/17 24/22 30/29 38/37 40/39
2
3
1310 nm
1310 nm ± 25 nm/1550 nm
1310 nm 1310 nm
21/20 27/25 33/32 40/39 44443333////41
2
3
3
3 mmmm3
3 3
10/12m
10/12m 10/12 m
10/12m10/12m
E6003CCCC E6004A
E6003E6003
1550 nm ± 25 nm 1310 nm
1550 nm 1550 nm
1 µs 10 µs 20 µs
41 13/13 18/18 23/23 30/30
4141
1.5
1.5 mmmm3 m
1.5 1.5
8888/1
/10000 m
m 10/12 m
/1/1
m m
1310 nm ± 25 nm/1550 nm
1310 nm 1310 nm
10 ns 100 ns
E6003BBBB
E6003E6003
1 µs 10 µs 20 µs
3 mmmm
3 3
10/12 m
10/12 m10/12 m
E6004A
E6004AE6004A
3 m
3 m3 m
10/12 m
10/12 m10/12 m
1550 nm ± 25 nm
1550 nm 1550 nm
1550 nm ± 25 nm
1550 nm 1550 nm
1 µs 10 µs
40/39
40/3940/39
30/30
30/3030/30
Module
Module E6008B
ModuleModule
Central Wavelength
1310 nm
1310 nm ± 25 nm/1550 nm
1310 nm 1310 nm
E6008B E6012A
E6008BE6008B
1550 nm ± 5 nm 1550 nm
1550 nm 1550 nm
1550 nm ± 25 nm/1625 nm
1550 nm 1550 nm
E6012A
E6012AE6012A
1625 nm ± 20 nm
1625 nm 1625 nm
Applicable Fiber single-mode single-mode
Pulsewidth 10 ns 100 ns
Dynamic Range1[dB]
Event Deadzone
Attenuation Deadzone
Module
Module E6005A
ModuleModule
2
3
Central Wavelength
24/22 29/27 35/34 42/41 45/43
850 nm
850 nm ± 30 nm/1300 nm
850 nm 850 nm
Applicable Fiber
Pulsewidth 10 ns 100 ns
Dynamic Range4[dB]
Event Deadzone
Attenuation Deadzone
Module
Module E6013A
ModuleModule
5
6
Central Wavelength
19/17 26/22 - /28 - /34 12/12 18/18 - /23
1310 nm
1310 nm ± 25 nm/1550 nm
1310 nm 1310 nm
1 µs 10 µs 20 µs
3 m
3 m 3 m
3 m3 m
10/12 m
10/12 m 12/14 m
10/12 m10/12 m
E6005A E6009A
E6005AE6005A
1300 nm ± 30 nm 850nm
1300 nm 1300 nm
multimode 62.5 µm multimode 62.5 µm
1 µs 10 µs
3 m 3 m
10 m 10 m
E6013A
E6013AE6013A
1550 nm ± 25 nm/1625 nm
1550 nm 1550 nm
Applicable Fiber single-mode
Pulsewidth 10 ns 100 ns
Dynamic Range1[dB]
Event Deadzone
2
Attenuation Deadzone
3
18/17/17 23/22/22 29/28/28 36/35/35 39/38/37
1 µs 10 µs 20 µs
3 m
3 m
3 m3 m
10/12/14 m
10/12/14 m
10/12/14 m10/12/14 m
45/43 22/18 27/24 34/30 41/40
45/4345/43
1625 nm ± 20 nm
1625 nm 1625 nm
10 ns 100 ns
850nm ± 30 nm/1300 nm
850nm 850nm
10 ns 100 ns
39/38/37
39/38/3739/38/37
1 µs 10 µs 20 µs
3 m
3 m3 m
12/14 m
12/14 m12/14 m
E6009A
E6009AE6009A
1300 nm ± 30 nm
1300 nm 1300 nm
The guaranteed values above are tested specifications. Agilent OTDR modules have the pulsewidths listed in “Pulsewidth“ on page 2.
40 43/ -
43/ -
4040
43/ -43/ -
1 µs
4
Notes:
Module Characteristics
Notes:
1 Measured with a standard single-mode
fiber at SNR=1 noise level and with 3 minutes averaging time. Optimize mode: dynamic
2 Reflectance pulsewidth, and with span
≤ –35 dB at 10 ns
1000 m at
4 cm sample spacing, optimize resolution. E6003C at 5 ns pulsewidth (< –40 dB); with FW Rev. 6.41 and higher
3 Typical Specification at Reflectance
≤ –50 dB at 30 ns pulsewidth, and with
4 km (typical value).
span
4 Measured with a standard 62.5
µm
guided index multimode fiber at SNR=1 noise level and with 3 minutes averaging time, optimize dynamic.
5 Reflectance and with span
6 Reflectance pulsewidth, and with span
≤ –35 dB at 5 ns pulsewidth,
4 km, optimize resolution.
≤ –35 dB at 10 ns
4 km.
Distance Accuracy
A
Offset Error: ± 1 m
Scale Error: ± 10
4
Sampling Error: ± 0.5
sampling spacing
Loss/Reflectance Accuracy
B
Backscatter Measurements: ± 0.05 dB (1 dB step), typical
Reflectance Measurements
C
± 2.0 dB, typical
Acoustic Noise Emission
< 40 dBA, not continuous. Data are results from type tests per ISO 7779 (EN 27779).
A Total distance accuracy = + scale error
B SNR
*
distance+ sampling error).
15 dB and with 1 µs, averaging
± (offset error
time max. 3 minutes.
C –20 dB to –60 dB, 100 ns
:
Source Mode
E600
E6003333AAAA,
, E6003
E6003BBBB, E6003
E600E600
, ,
E6004A, E6008B
E6004A, E6008B
E6004A, E6008BE6004A, E6008B
built-in CW dual
built-in CW dual
built-in CW dualbuilt-in CW dual
laser source
laser source
laser sourcelaser source
CW output power
CW output power –3 dBm
CW output powerCW output power
CW stability
CW stability
CW stabilityCW stability (15 min., T=const.) after a 10 minute warm-up with CW on
Optical Output
Optical Output User-exchangeable Connector Interfaces
Optical OutputOptical Output
Source Mode Modulation
Source Mode Modulation 270 Hz, 1 kHz and 2 kHz squarewave, Code
Source Mode ModulationSource Mode Modulation
, E6003CCCC,,,,
E6003E6003
, E6003, E6003
E6005A, E6009A
E6005A, E6009A E6012A, E6013A
E6005A, E6009AE6005A, E6009A
built-in CW dual
built-in CW dual
built-in CW dualbuilt-in CW dual
laser source
laser source
laser sourcelaser source
20 dBm (850 nm)
13 dBm (1300 nm)
±0.1 dB ±0.15 dB ±0.1 dB / ±0.15 dB
E6012A, E6013A
E6012A, E6013AE6012A, E6013A
built-in CW dual/triple
built-in CW dual/triple
built-in CW dual/triplebuilt-in CW dual/triple
laser source
laser source
laser sourcelaser source
3 dBm (E6012A)
8 dBm / 7 dBm / 6 dBm
1310 / 1550 / 1625 nm
5
Agilent E6006A Power Meter Submodule
Characteristics
Sensor element: InGaAs
Wavelength range: 800 – 1650 nm
Calibrated wavelengths: 850 nm,
1300 nm, 1310 nm, 1550 nm, 1625 nm (special wavelengths upon request).
Power range: +10 to –70 dBm
Max. input power (damage level):
+13 dBm / 20 mW
Display Resolution: 0.01 dB
Display Units: dBm, dB, mW,
pW
Display Contents
Calibrated λ in nm
Modulation frequency in Hz
Reference value in dB
Display Updates per second: 3
Optical input: User-exchangeable
Connector Interface
Applicable fiber type: 9/125 50/125
µm, 62.5/125 µm
2
µW, nW,
µm,
Specifications
Uncertainty at reference conditions:
± 3%
Power level: –20 dBm
Continuous Wave (CW)
Wavelength: 1300 nm
1310 nm
Fiber type: 50/125 Agilent/HMS-10 connector
Spectral bandwidth: up to 10 nm
Ambient temperature: +18°C to + 28°C
At day of calibration (add 0.3% for aging
of over one year; add 0.6% for aging of over two years).
Total uncertainty:
(1310, 1550 nm)
Power level: +0 to –50 dBm
Continuous Wave (CW)
Wavelength: 850 nm
1300 nm 1550 nm
Fiber type: SM to 50 (add 2% to total uncertainty for fiber
62.5
Straight and angled connectors
± 3 nm, 1550 nm ± 3 nm
± 3 nm, 1310 nm ± 3 nm, ± 3 nm,
µm).
± 3 nm,
µm graded index,
± 5% ± 0.5 nW
± 3 nm,
µm graded index
Supplementary Performance Characteristics
Automatic Zeroing Circuitry
Automatic Ranging
Modulation frequency recognition
(270 Hz, 1 kHz, 2 kHz) is available at power level between +10 and –45dBm (peak amplitude).
Dual Wavelength measurement is
available at power levels between +10 and –45 dBm (peak amplitude).
Wavelength encoding recognition
(350 Hz, 550 Hz) is available at power levels between +10 and –45 dBm (peak amplitude).
Reference value is presettable from
+30 to –80 dBm
Each calibrated wavelength has its
own reference memory.
The actual display content can be
transferred to reference memory (DISP
REF).
Hold Data functionality
General Specifications
Dimensions: ca. 120 mm H x 40 mm W
x 25 mm D (4.7 x 1.6 x 1.0”)
Weight: <130 g.
2
E6006A Power Meter Submodule not available for E6013A 1310/1550/1625 nm Mini-OTDR module
Ambient temperature: +10°C to +40°C
Within 2 years after calibration
6
Operating Temperature: 0°C to +50 °C
Storage Temperature: –40°C to +60°C
Humidity: 95% R.H. from 0°C to 40°C
non cond.
Recommended Recalibration Period:
2 years
Agilent E6007A Visual Fault Finder Submodule
Characteristics
Source type: Laser diode
3
Center Wavelength: 635 nm
(visible red light)
Output power level (CW)
0 dBm maximum
into 9 µm fiber (typ.): 3 dBm
Detection range: up to 5 km
Optical output: User-exchangeable
Connector Interface
± 10 nm
Supplementary Performance Characteristics
Continuous Wave and Blink
Mode (1 Hz for better visibility).
Single-mode and multimode
fibers applicable.
General Specifications:
Dimensions: ca. 120 mm H x
40 mm W x 25 mm D (4.7 x 1.6 x 1.0”)
Weight: < 100 g
Operating Temperature: 0°C to 40°C
Storage Temperature: –40°C to +60°C
Humidity: 95% R.H. from 0°C to 40°C
non cond.
3
E6007A Visual Fault Finder Sub-module not available for E6013A 1310/1550/1625 nm Mini-OTDR module
7
Accessories
The Agilent Technologies E6000C is a high performance time domain reflectometer. It is available in various configurations for the best possible match to the most common applications.
Instrument and Options
Agilent Product
Agilent Product Opt
Agilent ProductAgilent Product E6000C
Opt Description
OptOpt
003
006
AB0
AB1
AB2
AB8
AB9
ABD
ABE
ABF
ABJ
ABX
ABZ
ACB
AKB
AKE
Description
DescriptionDescription Mini-OTDR Mainframe
Color screen VGA LCD
B/W Screen VGA-LCD
Traditional Chinese user interface
Korean user interface
Simplified Chinese user interface
Turkish user interface
Portuguese user interface
German user interface
Spanish user interface
French user interface
Japanese user interface
Finnish user interface
Italian user interface
Russian (Cyrillic) user interface
Czech user interface
Romanian user interface
8
Modules
Agilent Product
Agilent Product Opt
Agilent ProductAgilent Product E6003A
E6003B
E6003C
E6004A
E6005A
E6006A
E6007A
E6008B
E6009A
E6012A
E6013A
Opt Description
OptOpt
021
022
021
022
021
022
021
022
021
021
022
021
021
022
021
022
Description
DescriptionDescription 1310/1550 nm standard performance single-mode module
with straight connector interface
with angled connector interface
1310/1550 nm high performance single-mode module
with straight connector interface
with angled connector interface
1310/1550 nm very high performance single-mode module
with straight connector interface
with angled connector interface
1310/1550 nm economy single-mode module
with straight connector interface
with angled connector interface
850/1300 nm high performance multimode module
Optical Power Meter
Visual Fault Finder
1310/1550 nm ultra high performance single-mode module
with straight connector interface
with angled connector interface
850/1300 nm economy multimode module
1550/1625 nm ultra high performance single-mode module
with straight connector interface
with angled connector interface
1310/1550/1625 nm very high performance single-mode module
with straight connector interface
with angled connector interface
9
Warranty, Service & Calibration Plan
For all Agilent Mini-OTDRs, the following support options are available.
R1280A – Return to Agilent Warranty and Service Plan. Available for 36 months (3 years) or 60 months (5 years).
R1282A – Return to Agilent Calibration Plan. Available for 36 months (3 years) or 60 months (5 years).
All modules come with a commercial calibration certificate.
Accessories supplied
The following accessories are supplied with your Mini-OTDR Mainframe:
Soft carrying case OTDR Trace Viewer PC Software
AC/DC adapter Support CD
Power cord RS232 cable
NiMH battery pack Shoulder Strap
User´s Guide
The following accessories are supplied with your Mini-OTDR modules:
Each single mode OTDR Module ordered with Option 021 is provided with 81000FI (FC/PC) and 81000 KI (SC) connector interface
Each single mode OTDR Module ordered with Option 022 is provided with 81000NI (FC/APC) and 81000 KI (SC) connector
interface
E6005A and E6009A multi mode OTDR Modules are provided with 81000 KI (SC) and 81000 VI (ST) connector interface
Additional Accessories
The following accessories are also available. To order these products, please contact your Agilent Technologies representative.
Product
Product Description
ProductProduct E6080A
E6081A
E6082A
N3980A
E6092A
24542U
E6000-13601
Description
DescriptionDescription Spare NiMH battery pack
Mini-Keyboard
Hard transit case
TM
192 MB CompactFlash
OTDR Toolkit III Plus trace analysis & acceptance test documentation software
RS232 cable, 9-pin to 9-pin
OTDR Support CD
card with PCMCIA adapter
10
Connector Interfaces
If you want your Mini-OTDR supplied with an angled connector, please order option #022. (Option #022 is only available for single­mode modules). Straight connector interfaces must be ordered with option #021.
Optical Connectors
Agilent Model No.
Agilent Model No. Description
Agilent Model No.Agilent Model No. 81000SI
81000HI
81000NI
81000FI
81000KI
81000VI
81000LI
Description
DescriptionDescription DIN connector interface
E2000 connector interface
FC/APC connector interface
FC/PC connector interface
SC connector interface
ST connector interface
LC connector interface
Product Documentation
Agilent Part Number
Agilent Part Number Title
Agilent Part NumberAgilent Part Number N3900-90AJ1
E6000-91031
E6000-91017
E4310-91016
Title
TitleTitle Cleaning Procedures for Lightwave Test and Measurement Equipment pocket guide
Mini-OTDR User´s Guide (also available in other languages)
OTDR Pocket Guide (also available in other languages)
OTDRs Programming Guide
11
Safety Information
All laser sources specified by this data sheet are classified as class 1M or class 2 according to IEC 60825–1 (2001).
All laser sources comply with FDA 21 CFR
1040.10 except for deviations pursuant to Laser Notice No. 50, dated 2001-July-26.
All laser sources bear the laser warning label
The class 1M laser sources (all OTDR test engines) bear the laser label
The class 2 laser source (E6007A) bears the laser label
All modules also bear the CE conformity marking
You must return instruments with malfunctioning laser modules to an Agilent Technologies Service Center for repair and calibration, or have the repair and calibration performed on-site by Agilent Technologies personnel.
Agilent Technologies Test and Measurement Support, Services, and Assistance
Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Support is available for at least five years beyond the production life of the product. Two concepts underlie Agilent's overall support policy: "Our Promise" and "Your Advantage."
Our Promise
Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you use Agilent equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabilities, at no extra cost upon request. Many self-help tools are available.
Your Advantage
Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out­of-warranty repairs, and on-site education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products.
By internet, phone, or fax, get assistance with all your test & measurement needs
Online assistance: www.agilent.com/comms/otdr
Phone or Fax
United States: (tel) 1 800 452 4844
Canada: (tel) 1 877 894 4414 (fax) (905) 206 4120
Europe: (tel) (31 20) 547 2323 (fax) (31 20) 547 2390
Japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840
Brasil (tel) (11) 4197 3600 (fax) (11) 4197 3800
Latin America: (tel) (305) 269 7500 (fax) (305) 269 7599
Australia: (tel) 1 800 629 485 (fax) (61 3) 9210 5947
New Zealand: (tel) 0 800 738 378 (fax) 64 4 495 8950
Asia Pacific: (tel) (852) 3197 7777 (fax) (852) 2506 9284
Product specifications and descriptions in this document subject to change without notice.
Copyright © 2004 Agilent Technologies Printed in Germany. May 04, 2004
5988-2302EN
Loading...