The Agilent 81110A pulse pattern generator is the industry-standard for pulse, pattern, data and PRBS generation up to 165/330 MHz.
It provides high quality signals and leading flexibility that meets virtually all application needs. This instrument is a must for all labs.
Other highlights are:
• The Agilent 81111A 165 MHz 10 V module with variable transitions.
• The Agilent 81112A 330 MHz 3.8 V module has differ­ential outputs and two selectable transition times.
• Integrated in one instrument, which increases signal performance, minimizes cabling, space and test time.
• Glitch free change of timing parameters (delay, fre­quency, transition time, width, delay cycle).
• Programming language compatible with Agilent 81101A, 81104A and 81150A.
Choose your hardware
Code Description
81110A 165/330 MHz mainframe
#DOC Printed documentation, variouslocalizations
#1CP Rackmount kit with handle
#OBW Service docummentation
#UFJ 1 MB SRAM memory card
#UK6 Cal. certificate with test data
#NOC Mainframe only
#UN2 Rear panel connectors
81111A 165 MHz interface, 1 channel
81112A 330 MHz interface, 1 channel
Key specifications Description
81110A Mainframe for 81111A and 81112A
interfaces
Waveforms Pulse, pattern with PRBS, NRZ, RZ,
DNRZ
Channels 1 or 2, differential outputs, BNC
(Single ended for 81111A)
Output amplifier 81111A 81112A
Transition time (10/90) 81111A 81112A
Output impedance 50 Ω/1 kΩ selectable
Pattern memory 16 kBit/channel
Programming interfaces
Supported drivers Agilent VEE, NI Labview
165 MHz, 100 mV to 10 V 330 MHz, 100 mV to 3.8 V
2.5 ns to 100 ms, variable 800 ps or 1.6 ns
LAN, SCPI 1992, IEEE 488.2 (GPIB)
Quick Fact Sheet
Pulse pattern generator selection guide
Model Bandwidth Channels Voltage
81101A 50 MHz 1-ch 100 mV to 10 V
81104A + 81105A 80 MHz 1 or 2 ch 100 mV to 10 V
81150A 120 MHz 1 or 2 ch 50 mV to 10 V
81130A + 81131A 400 MHz 1 or 2 ch 100 mV to 3.8 V
81130A + 81132A 660 MHz 1 or 2 ch 100 mV to 2.5 V
Complementary products
Model Description
DSO/MSO 6000, 7000 InfiniiVision 7000 Series Oscilloscopes up to 1 GHz bandwidth
DSO/MSO 8604A Infiniium DSO/MSO Oscilloscope with 800 MHz bandwidth
DSO/MSO 5000 InfiniiVision 5000 Series Oscilloscopes up to 500 MHz bandwidth
DSO 3000 Economy DSO 3000 Series up to 200 MHz bandwidth
Characteristics on a pulse pattern shape
All parameters can be selected and edited with the Agilent Pulse Pattern Generators
Typical applications
• Distorted signals for stress tests (Application Note 5989-4709EN)
• Sensor simulation
• Clock signal generation (Application Note 5968-5844E)
• Radar distance testing (Application Note 5968-5843E)
• Disc drive tests (Application Note 5968-5845E)
• Diodes - LEDs
• PRBS generation
• Pulsed IV measurements
• System trigger source
• Capture and reproduce live signals
Related literature
Pub Number Name
5980-1215E Agilent 81100 Family of Pulse/Pattern
Generators
5980-0489E Pulse Pattern and Data Generators For
Digital and Analog Testing
Delay: Time Delay: Phase
Width
Duty Cycle
Hi
Amp
Leading
TTL or ECL
Edge
Lo
Offset
Frequency, Period
Technical data, availability and pricing subject to change without notice. © Agilent Technologies, Inc. 2010, Printed in USA, November 22, 2010
5990-4564EN
Trailing Edge
Recommended service options
Additional two years of Return-to-Agilent warranty Additional two years of Return-to-Agilent calibrations For more information go to www.agilent.com/find/removealldoubt
www.agilent.com/find/81110
Loading...