Agilent
Coaxial Frequency Meter
536A 0.96 to 4.2 GHz
537A 3.7 to 12.4 GHz
Data Sheet
• Broadband
• Direct-reading
• No spurious resonances
• High resolution, easy to read dial
• Accuracy specified with T”temperature and humidity
537A
536A
Description
frequencies 960 MHz to 4.2 GHz and 3.7 to 12.4 GHz can be read directly and
accurately with Agilent 536A and 537A coaxial frequency meters. Convenient
readout with high resolution is provided by long spiral dials. These dials have
all frequency calibrations visible so you can tell at a glance the specific portion
of each band you are measuring.
Overall accuracy of these frequency meters is 0.17% and includes such variables
as dial calibration, temperature variation over a 20 °C range, relative humidity
effects, and backlash. Extreme resolution and readability permit individual
scale correction charts to be made and readings repeated with even higher
accuracy. Calibration marks are every 2 MHz for the 536A and every 10 MHz
for the 537A. Even at the high frequency end of the dial, minimum spacing
between calibrations is such that you can easily resolve small differences of
frequency. The tuning plunger is spring-loaded to eliminate backlash.
There are no spurious resonances at any setting. A one-quarter wavelength
tuning mode is employed and capacitively loaded to prevent the three-quarter
wavelength mode of higher frequencies from being excited and giving a spurious
response. A well-matched section of strip line couples microwave energy into
the cavity. Resonance is indicated by a dip in output power of approximately
1 dB. Cavity Q is typically greater than 1500 (536A).
Specifications
536A 537A
Frequency range 0.96 to 4.2 GHz 3.7 to 12.4 GHz
Dial accuracy ± 0.10% from 1 to 4.2 GHz 0.1% (includes backlash)
±0.15% from 0.96 to 1 GHz
Overall accuracy
1
± 0.17% from 1 to 4.2 GHz 0.17%
±0.22% from 0.96 to 1 GHz
Dip at resonance At least 1 dB from 1 to 4 GHz At least 1 dB
At least 0.6 dB from 0.96 to 1 GHz
Reflection coefficient Less than 0.091 (1.2 SWR, Less than 0.33 (2.0 SWR,
off resonance 20.8 dB return loss 9.5 dB return loss)
Calibration increments 2 MHz 10 MHz
Connectors Type-N female Type-N female
Dimensions Height: 9.125 inches (232 mm) Height: 5.75 inches (146 mm)
Diameter: 6 inches (152 mm) Base Diameter: 3.5 inches
(89 mm)
Width (including connectors):
4.625 inches (118 mm)
Weight Net, 10 lb (4,5 kg.) Net, 3.3 lb (1,5 kg)
Shipping, 13 lb (5,9 kg) Shipping, 4.5 lb (2 kg)
1. Includes allowance of ± 0.02% for 0 to 100% relative humidity, ± 0.0016% per °C from 13 to 33 °C
and 0.03% backlash.
www.agilent.com/find/emailupdates
Get the latest information on the
products and applications you select.
Agilent Technologies’ Test and Measurement Support,
Services, and Assistance
Agilent Technologies aims to maximize the value you
receive, while minimizing your risk and problems. We
strive to ensure that you get the test and measurement
capabilities you paid for and obtain the support you need.
Our extensive support resources and services can help
you choose the right Agilent products for your applications
and apply them successfully. Every instrument and system
we sell has a global warranty. Support is available for at
least five years beyond the production life of the product.
Two concepts underlie Agilent’s overall support policy:
“Our Promise” and “Your Advantage.”
Our Promise
Our Promise means your Agilent test and measurement
equipment will meet its advertised performance and
functionality. When you are choosing new equipment, we
will help you with product information, including realistic
performance specifications and practical recommendations
from experienced test engineers. When you receive your
new Agilent equipment, we can help verify that it works
properly and help with initial product operation.
Your Advantage
Your Advantage means that Agilent offers a wide range of
additional expert test and measurement services, which
you can purchase according to your unique technical and
business needs. Solve problems efficiently and gain a
competitive edge by contracting with us for calibration,
extra-cost upgrades, out-of-warranty repairs, and onsite
education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity,
optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement
accuracy for the life of those products.
Agilent T&M Software and Connectivity
Agilent’s Test and Measurement software and connectivity
products, solutions and developer network allows you to
take time out of connecting your instruments to your computer with tools based on PC standards, so you can focus
on your tasks, not on your connections. Visit
www.agilent.com/find/connectivity
for more information.
For more information on Agilent Technologies’ products,
applications or services, please contact your local
Agilent office. The complete list is available at:
www.agilent.com/find/contactus
Product specifications and descriptions in this document
subject to change without notice.
© Agilent Technologies, Inc. 2004
Printed in USA, October 1, 2004
5952-1250
Phone or Fax
United States:
(tel) 800 829 4444
(fax) 800 829 4433
Canada:
(tel) 877 894 4414
(fax) 800 746 4866
China:
(tel) 800 810 0189
(fax) 800 820 2816
Europe:
(tel) 31 20 547 2111
Japan:
(tel) (81) 426 56 7832
(fax) (81) 426 56 7840
Korea:
(tel) (080) 769 0800
(fax) (080)769 0900
Latin America:
(tel) (305) 269 7500
Taiwan:
(tel) 0800 047 866
(fax) 0800 286 331
Other Asia Pacific
Countries:
(tel) (65) 6375 8100
(fax) (65) 6755 0042
Email: tm_ap@agilent.com
Contacts updated 9/17/04