ASK Proxima C200 (DP6500x) Projector
RS232/Command Line Interface Guide
Communication Configuration
To control this projector from an RS-232 control system, connect a null modem cable and set the control system serial port
settings to match the following communication configuration*:
RS-232 Port Settings
Setting Value
Bits per second 19,200
Data bits 8
Parity None
Stop bits 1
Flow control None
Emulation VT100
Command Format
All commands consist of 3 alpha characters followed by a request, all enclosed in parentheses. The request can be a read
request (indicated by a "?") or a write request (indicated by 1 to 4 ASCII digits).
A read request example:
• (AAA?) where
• ( starts the command
• AAA denotes the command
• ? denotes the read request
• ) ends the command
A read command returns the range and the current setting, for example:
Read Command Examples
Function Command Response
Brightness (BRT?) (0-22, 10)
Volume (VOL?) (0-80, 0)
Lamp Hours (LMP?) (0-9999, 421)
A write request example:
(AAA####) where
• ( starts the command
• AAA denotes the command
• #### denotes the value to be written
• (leading zeros not necessary)
• ) ends the command
Some commands have ranges, while others are absolute. If a number greater than the maximum range is received, it is
automatically set to the maximum number for that function. If a command is received that is not understood, a "?" is
returned. With absolute settings, "0" is off, 1-9999 is on. The one exception is the Power command, where 0 is off and 1 is
on.
To assure the projector can process a command, wait 3 seconds before entering the next command.
Not all commands are supported for all projectors. If an unsupported command is issued, the command will be ignored. If a
command is received that is not understood, a ‘?’ character will be returned indicating the command was not understood.
Limitations
The CLI cannot respond to commands coming in at a high-rate. Therefore, a delay must occur between commands to ensure
that the command gets properly executed. To assure the projector can process a command, wait 3 seconds before entering
the next command.
Function Command Min Max Default Notes
Auto Power APO 0 1 0
Aspect Ratio
0 – Native 1 – 16:9 2 – 4:3
Auto Source ASC 0 1 1
Balance
< 24 – softer right >24 – softer left
Blue Gain BCG 1 63 32 S
Brightness BRT 8 248 128 S
Blank Screen BSC 0 2 1
Blank BLK 0 1 -1 W
Ceiling CEL 0 1 0
Color CLR 8 248 128 S
Contrast CON 8` 248 128 S
Color Space
0 – RGB 1 – SMPTE240 2 – REC709 3 – REC601 7 – Auto
Language
0 – English 1 – French 2 – German 3 – Spanish 4 – Traditional Chinese 5 –
Japanese 6 – Korean 7 – Portuguese 8 – Russian 9 – Norwegian 10 –
Simplified Chinese 11 – Italian
Time In Hours Last Bulb1 Lasted LB1 0 32767 0 R
Time In Hours Last Bulb2 Lasted LB2 0 32767 0 R
Time In Hours Last Bulb3 Lasted LB3 0 32767 0 R
Lamp Lit LML 0 1 0 R
Lamp Hours LMP 0 32767 0 R
Lamp Reset LMR 0 32767 0
Lamp Total On Time (All Bulbs) LMT 0 2147483647 0 R
Low Power LPE 0 1 0
Menu MNU 0 1 0
Phase MSS 0 31 --- M,A
Mute MTE 0 1 0
LAN 0 11 0
Tracking MTS --- --- --- M,A
Menu Navigation
0 – up 1 – down 4 – select
Unit Total Time On ONL 0 2147483647 0 R
Overscan OVS 0 1 0 S,V
Presets
0 – Presentation 1 – Photography 2 – Film 3 – Video 10 – User 1 11 – User 2
12 – User 3