Ashly FA 125.2, FA 125.4, FA 250.4 User Manual

Page 1
FA Series
High-Density Power Amplifiers.
Perfect for conference rooms or anywhere space is at a premium.
ou don’t have to sacrifice
Y
space to get up to four channels of clean, robust ampli­fier power.
The half- and one-rack-space size FA Series high-density Class D amps belie their output: up to 125 W x 4 in a half rack space…up to 250 W x 4 in one rack space!
FA amplifiers can nestle under conference tables, inside kiosks and trade show exhibits, recep­tion area counters and any­where else a larger amplifier just won’t fit.
Naturally, they have the rugged reliability that Ashly is known for…including a 5-year warranty.
❚ Conference Rooms
❚ Trade Show Exhibits
❚ Huddle Rooms
❚ Inside Displays & Kiosks
❚ Bars and Restaurants
❚ Reception Areas
❚ Hotel Lobbies
FA 125.2 FA 125.4
FA 250.4
DATA
SHEET
on
PAGE THREE
Page 2
Page 2 of 4
FA Series
This page intentionally left blank*.
High-Density Power Amplifiers
Data Sheet begins on the next page.
*Done so that those fortunate to have printers with
2-sided printing capabilities can print out the Data Sheet
on one sheet of paper.
Page 3
Page 3 of 4
FA Series
he FA Series is designed for easy
T
and flexible placement, going where other amps cannot: under conference tables, behind displays, inside kiosks… anywhere high-quality, reliable power is needed, but space is limited.
The ½ RU FA-125.2 & FA-125.4 offer
125W of efficient Class D power per channel (x 2 on the 125.2 and x 4 on the
125.4). With selectable Low Z or Hi Z operation, they’re capable of powering low-Z, full range speakers as well as 70V and 100V distributed speaker systems.
Where additional power is needed, the full 1 RU, 4 x 250W FA-250.4 (also designed for Hi/Low Z) delivers seriously high power-density in a 1U package.
The FA-125.2 and FA-125.4 can share power between channel pairs up to a total of 250W total per pair. So a system may be designed with a180W load on one channel and 70W on the other. Or if a single channel only is driven, 250W can be output to drive a heavier load such as subwoofer.
❚ 2 and 4-channel models ❚ 125 and 250 W @4Ω ❚ 70/100V capability ❚ Efficient Class D design ❚ Energy Star certified ❚ Adaptive fan cooling ❚ Installer-friendly Euroblock
connectors
❚ 80Hz HPF (in Hi Z Mode) ❚ Front panel Signal/Clip/
Mute LED
❚ Front panel Input Level
controls and Power On/
Off w/lockout
❚ USB port for firmware
updates
❚ Power-sharing on ½ RU
models up to 250W
❚ 5-Year Warranty
FA SERIES SPECIFICATIONS
Configuration
Size Fo rmat (HxW) 1RU x 1/2 19” 1RU x 19”
Output Power (per channel)
High-Density Power Amplifiers
4Ω / 8Ω all
Chs
FA-125.2 2
FA-125.4 4
Width
½ 19 "
½ 19 "
FA-250.4 4 1U 250W 250W 250W
FA 125.2 FA 125.4 FA 2 50.4
Configuration Pre-BTL
# of Channels 2 4 4
2 Ohm Not Recommended
4 Ohm 125W 250W
8 Ohm 125W 250W
16 Ohm 12 5W 250W
70V 125W 250W
100V** 12 5W 250W
Power Sharing Yes x 2 (up to 250W ) No
chs.driven 70V 100V
125W 125W 125W
125W 125W 125W
Crosstalk <65dB
Frequency Response
(±0.05d B)
S/N Ratio (20Hz-
20kHZ, unweighted)
Input Sensitivity
THD + Nois e < 0.5%
Damping Factor (8 Ohms < 1kH z)
US toll-free +1.585.872.0010
Sales@Ashly.com • www.Ashly.com
FA 125.2 FA 125.4 FA 2 50.4
–10dBV (0.316Vrms)/+4dBu
(1.228Vrms), Selectable
continued on the next page
Fax +1.585.872.0739
FA 125.4
FA 250.4
FA 125.2
20HZ-20kHz
>102d B
>25 0
Page 4
FA Series
High-Density Power Amplifiers
FA SERIES SPECIFICATIONS
FA 125.2 FA 125.4 FA 2 50.4
Power Consumption (1/8 full power, 1kHz sin e-wave on all channel s, in Watts)
Sleep (En ergy Star) <0.5 <0.5 <0.5
Idle L o-Z 8 15 25
Idle Hi-Z 13 25 30
1/8 Power (4 O hms) 52 104 196
1/8 Power (8 O hms) 49 96 186
1/8 Power ( 70V) 51 101 191
1/8 Power ( 100V) 48 96 181
Thermal Dissipation (BTU/hour w ith typical inpu t, all channels driven, 120VAC)
Sleep mode <1.7 <1 .7 <1.7
Idle Lo-Z (no s ignal) 28 52 86
Idle Hi-Z (no si gnal) 45 85 103
1/8 max po wer,
4 Ohm
1/8 max po wer, 8
1/8 max po wer, 70V 69 133 226
1/8 max po wer, 100V 58 116 191
Ohm
Voltage Gain(per output mo de and input sensitivi ty setti ng, in dB)
Low Z @ –10dB V 43.1
Hi-Z 70V @–10d BV 46.9
Hi-Z 100V @ –10d BV 49.1
Low Z @ +4 dBu 31.3
Hi-Z 70V @ +4 dBu 3 5.1
Hi-Z 100V @ +4 dBu 3 7.3
I/O Features
HPF
Clip Limiter Yes (at clip thr eshold +24dBu,
Connectors
Input
Output
GPIO
USB USB-C for Firmware update
DIP Switches
1) Note: When maki ng a true co mpariso n of energ y effici ency, one mus t look at
the Thermal Dissipation (BTU/hr) numbers for a product. All other efficiency,
i.e. “perc entage ” numbers a re not st andards b ased, and t herefo re may be marketing hype. Ashly Audio builds highly efficient Class-D amplification with SMPS t hat will eq ual or surp ass the co mpetit ion on BTU /hr therm al outpu t (unused e nergy pe r channel gi ven off a s heat). Ple ase check o ur publish ed BTU/hr. specifications for more information.
2) FA 125.2:two channels
1
72 144 243
62 116 209
Yes. 80Hz (in H iZ Mode,
non-defeatable)
non-defeatable)
Removeable Euroblock/
Balanced 6-pole (pr)
Removeable Euroblock/
2-pole (p er ch)
Removeable Euroblock/ 6-pole
DC volume p er channel pair2,
Standby, Fault Out
1 HiZ/L owZ Ch 1
2 HiZ/LowZ Ch 2
3 Not Used Hi Z/LowZ Ch 3
4 Not Used HiZ /LowZ Ch 4
5 70/100V
DIP Switches (continued)
FA 125.2 FA 125.4 FA 2 50.4
6 Input Sensitvi ty (–10/+4dB)
7 Standby Pola rity (NO/NC)
8 Front P anel Lockout
LEDs/Indicators
Front L ED (per
channel)
Front L ED (Main)
Green: Signal Present, Yellow:
Limit (+24dbu), Red: Mu te/Protec t
White-On, Blink (0.5Hz)-Standby,
Dark-Off
General
Pre-Sleep Mode
Sleep Mode
Standby Mode
Remote Control
Amplifier Protectio n
Standby Switch Soft S witch w/ LED back light
Power Connector IEC
Attenuators
Power Supply 100-240VAC, 50-60Hz
Minimum Startup
Environmental
Safety Compliance
>15 minutes inactivity, all channels
muted, wake-on-audio
>29 minutes inactivity, Energy
Star® power saving mode, power
LED blin ks every two s econds,
wake-on-audio
Contact closure activated,power
LED flashes evenly @1Hz
Options
Cooling
Voltage
WR-1, WR -1.1 DC level con trol
Adapt ive Fan Cooling
(side -to-r ear venting)
Over-temperature, output DC,
output over-power, AC mains
voltage, mains fuse
Reces sed Front panel I nput Level
85VAC@ 120V nominal, 170VAC@
240V nominal
32°F-104°F, (0°C-40°C)
non-condensing
UL, Ener gy Star®, CE, FC C Class
(per ch)
B, RoHS
Weights & Dimensions • US measure
Unit Weight (lbs) 3.55 5.36 7.8 9
Unit Height (in.) 1.7 2 1.72 1.72
Unit Wi dth (in.) 8.66 8.66 1 7.3 3
Unit Dep th (in.) 10.32 13.3 11.54
Shipping Weight (lbs) 5.66 7.1 4 1 0.12
Shipping Height (in.) 8.94 8.9 4
Shipping Width (in.) 23 28.7
Shipping Depth (in.) 19.4 23.2
Weights & Dimensions • Metric measure
Unit Weight (kg) 1.61 2.4 3 3.6
Unit Height (mm) 43.7 43.7 43.7
Unit Wi dth (mm) 220 220 440
Unit Dep th (mm) 262 338 293
Shipping Weight (kg) 2.3 7 3.24 4.63
Shipping Height (mm) 227 227
Shippin g Width (mm) 584 729
Shippin g Depth (mm) 492 589
© 2020 A shly Aud io, Inc, Al l Rights R eserv ed. Ashl y and Aqu aContr ol are tr ademar ks or registered trademarks of Ashly Audio, Inc. All other trademarks are the propetry of their respective holders. V120A
All Specifications are subject to change.
Page 4 of 4
Wall mount bracket for
FA 125.2 & FA 125.4
Rack rear support for FA 250.4
FA 250.4
Rack Mount
FA 125.2. & FA 125.4 Single Rack Mount
USER MANUAL
Or download the complete User Manual at
http://ashly.com/wp­content/uploads/2019/ 09/FA_Manual.pdf
FA SERIES ARCHITECT & ENGINEERING SPECIFICATIONS
in .txt and MS Word .docx format are available in the
DOWNLOADS section of
http://ashly.com/fa series-amplifiers/
FA SERIES 2D AUTOCAD FILES
are available in the DOWNLOADS section of
http://ashly.com/fa series-amplifiers/
Ashly Audio, Inc. • 847 Holt Road • Webster, NY
USA • US toll-free +1.585.872.0010
Fax +1.585.872.0739 •Sales@Ashly.com
www.ashly.com
FA 125.2. & FA 125.4 Dual Rack Mount
Loading...